Overview
Place of Origin: |
USA |
Brand Name: |
GE |
Model Number: |
IC200ALG240 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Model: |
IC200ALG240 |
|
Module Type: |
Analog Input Module |
|
Dimensions (HxWxD): |
11 x 5.5 x 6.5 cm |
|
Weight: |
0.2 kg |
|
Channels: |
8 inputs |
|
Module ID: |
FFFF9802 |
|
Isolation: |
User input to logic and frame ground: 250 VAC continuous, 1500 VAC 1 min; Group-to-group: N/A; Channel-to-channel: 250 VAC continuous, 1500 VAC 1 min |
|
LED Indicators: |
FLD PWR (logic and user power present); OK (module status) |
|
Backplane Current Consumption: |
5 VDC: 15 mA max; 3.3 VDC: 120 mA max |
|
External Power Supply: |
+19.5 to +30 VDC; 100 mA max plus load currents |
|
Thermal Derating: |
None |
|
Diagnostics: |
High/Low limit, Over/Underrange, Open wire, Loss of field power, Non-volatile memory fault |
|
Input Operating Range: |
Current: +1 to 20 mA; Voltage: ±10 VDC |
|
Accuracy (25°C): |
±0.1% max of full scale |
|
Temperature Coefficient: |
Current: 45 ppm/°C typical, 90 ppm/°C max; Voltage: 30 ppm/°C typical, 60 ppm/°C max |
|
Resolution (1 LSB): |
Current: 381 nA nominal; Voltage: 381 µV nominal |
|
Update Rate: |
~20 ms max @ 50 Hz; ~16.7 ms max @ 60 Hz |
|
Crosstalk Rejection: |
70 dB minimum |
|
Input Default: |
Hold Last State (default), 0 configurable |
|
Input Resistance: |
Current: 150 Ω; Voltage: 760 kΩ |
|
Field Input Filter: |
Digital with programmable 50/60 Hz notch; 3 dB corner frequency 10 Hz ±25% |
|
Normal Mode Rejection: |
35 dB minimum |
|
Field Input Range: |
Current: ~0 to 25 mA; Voltage: ~–12.5 V to +12.5 V |
|
Max Input (No Damage): |
Current: ±35 mA continuous; Voltage: ±17.5 V continuous |
Description
The IC200ALG240 Analog Input Module with 8 isolated inputs is an intelligent module that accepts input signals from up to 8 analog devices and provides input data with 16 bits of resolution. The Analog Input Module features 8 analog inputs with 16-bit resolution, 0.1% accuracy at 25 C, and 1500v AC isolation. It supports standalone I/O station configurations and allows hot insertion. The module ensures quick, cost-effective wiring without the need for special tools. It includes a programmable digital field input filter with 50 or 60 Hz notches and diagnostic capabilities such as high/low limits, open wire detection, field power loss, and non-volatile memory fault diagnostics.
Applications
Light industrial manufacturing plants: Laser displacement sensors or potentiometers for position feedback in CNC machine tools and stamping machines.
Food and beverage plants: Monitoring packaging line pressure, tank levels, and conveyor belt speed adjustment signals.
Plastics and rubber processing plants: Monitoring pressure sensors in injection molding machines and mold positions.
Features
1 Eight isolated 4-20mA current input channels
2 Sixteen-bit converter resolution
3 Open wire detection
4 High-accuracy factory calibration
5 Per-channel selection of 4-20mA current or +/–10V voltage inputs
6 Selectable input filter to reject normal mode AC pickup noise
7 Selection of default/hold last state operation
8 Per-channel selection of default values
9 Per-channel selection of under-range and over-range diagnostics levels
10 Per-channel selection of alarm levels
11 Per-channel scaling
12 Field re-calibration on command
Diagnostics
1 Over-Range: The module reports an Over Range fault if an input value is greater than approximately +12.5 volts or 25mA
2 Under-Range: The module reports an Under Range fault if an input value is approximately 0mA on an current channel or –12.5 volts on a voltage channel
3 Open Wire: The module reports an Open Wire fault on current inputs if the configuration of the low end of the range is greater than or equal to approximately 2.0mA, but the input is not detecting current
4 Loss of Field Power Supply: The module reports a Loss of Field Power fault if field power is not present (also indicated by the FLD PWR LED). Inputs default as specified by the configuration
5 High Limit: The module reports a High Alarm fault if an input value is greater than or equal to the value specified by the “Alarm High” configuration parameter
6 Low Limit: The module reports a Low Alarm fault if an input value is less than or equal to the value specified by the “Alarm Low” configuration parameter
7 Non-volatile Memory Fault: The module reports this fault only during field recalibration, if a non-volatile memory fault is detected
Compatibility
This module is compatible with:
1 PLC CPU firmware version 1.20 or later
2 EtherNet NIU EBI001 all versions
3 Genius NIU GBI001 Firmware version 1.10 or later
4 Profibus NIU PBI001 Firmware version 1.10 or later
5 DeviceNet NIU DBI001 Firmware version 2.10 or later
6 For GBI001 and PBI001, NIU version 2.0 or above is required to perform software configuration
FAQ
Q: What is a 16-Bit Versamax Analog Input Module IC200ALG240?
A: A 16-bit Versamax Analog Input Module is an industrial automation component designed to convert analog signals, such as voltage or current, into digital data that can be processed by a Programmable Logic Controller (PLC). It enables precise monitoring and control of analog inputs in industrial applications, allowing for accurate data acquisition from sensors and other field devices
Q: What are the key features of this IC200ALG240?
A: The 16-bit Versamax Analog Input Module offers high-resolution signal processing, ensuring precise data conversion for critical automation processes. It supports multiple input types, including voltage and current, making it versatile for various applications. The module is designed to provide high accuracy while minimizing noise interference, ensuring reliable performance in industrial environments
Q: What input signal ranges does the IC200ALG240 support?
A: This module supports a range of input signal types to accommodate different industrial needs. Commonly supported ranges include 0-10y, 4-20mA, and -10v to +10y, providing flexibility for integration with various sensors and field devices