Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
 ai880a 3bse039293r1high integrity analog input module-0

For ABB

Home >  Products >  For ABB

AI880A 3BSE039293R1 High Integrity Analog Input Module

  • Overview
  • Specifications
  • Description
  • Applications
  • Features and benefits
  • Compatibility
  • Diagnostics
  • FAQ
  • Recommended Products
Overview

Place of Origin:

Sweden

Brand Name:

ABB

Model Number:

AI880A 3BSE039293R1

Packaging Details:

Original new Factory Sealed

Delivery Time:

5-7 days

Payment Terms:

T/T

Supply Ability:

In stock

Specifications

Model:

AI880A 3BSE039293R1

Type:

High Integrity Analog Input Module

Dimensions:

45 mm (W) x 102 mm (D), 111 mm with connector x 119 mm (H)

Weight:

0.15 kg

Signal Type:

Unipolar, single-ended

Signal Range:

0–20 mA, 4–20 mA

Number of Channels:

8

HART Support:

Yes

SOE Support:

No

Redundancy:

Yes

High Integrity:

Yes

Intrinsic Safety:

No

Mechanical System:

S800

Resolution:

12-bit

Input Impedance:

250 Ω (with TY801 shunt stick)

Isolation:

Groupwise isolated from ground

Over Range:

+12% (0–20 mA), +15% (4–20 mA)

Accuracy:

Max. 0.1%

Temperature Drift:

Max. 50 ppm/°C

Input Filter (0–90% rise):

190 ms

Update Cycle Time:

10 ms

Current Limiting:

Built-in transmitter power limiting

Max Field Cable Length:

600 m (656 yards)

Max Input Voltage (Non-destructive):

11 VDC

NMRR (50/60 Hz):

>40 dB

Rated Insulation Voltage:

50 V

Dielectric Test Voltage:

500 VAC

Power Dissipation:

2.4 W

Current Consumption (+5V Modulebus):

45 mA

Current Consumption (+24V Modulebus):

Max. 50 mA

Current Consumption (+24V External):

4 mA + transmitter current (max 260 mA)

CE Mark:

Yes

Electrical Safety:

EN 61010-1, UL 61010-1, EN 61010-2-201, UL 61010-2-201

Hazardous Area Certification:

Class I Div 2, Zone 2 (cULus, ATEX)

Marine Certification:

ABS, BV, DNV, LR

Description

The AI880A 3BSE039293R1 High Integrity Analog Input Module is designed for single and redundant configuration. The module has 8 current input channels. The input resistance is 250 ohm.

The module distributes the external transmitter supply to each channel. This adds a simple connection to distribute the supply to 2- or 3-wire transmitters. The transmitter power is supervised and current limited. All eight channels are isolated from the ModuleBus in one group. Power to the Module is generated from the 24 V on the ModuleBus.

The AI880A 3BSE039293R1 complies with the NAMUR recommendation NE43, and supports configurable over- and under range limits.

Applications

Petrochemical plants: Emergency shutdown (ESD) systems and safety interlocks for high-pressure reactors.

Offshore oil production plants: Wellhead control, overflow protection, and fire and gas (F&G) monitoring systems.

Coal chemical production plants: Gasifier monitoring and combustible/toxic gas detection and alarm systems.

Natural gas pressure regulating plants: Long-distance pipeline emergency shutdown and overpressure protection systems.

Coal-fired power plants: Redundant monitoring of critical safety parameters such as boiler over-temperature and over-pressure.

Hazardous waste treatment plants: Monitoring of environmental safety indicators in incineration processes.

Features and benefits

8 channels for 0...20 mA, 4...20 mA, single ended unipolar inputs

Single or redundant configuration

1 group of 8 channels isolated from ground

12 bit resolution

Loop Supervised DI function

Configurable alarm limit for field power outputs

Configurable over/under range for current inputs

Current limited transmitter supply per channel

Advanced on-board diagnostics

Certified for SIL3 according to IEC 61508

Certified for Category 4 according to EN 954-1

Complies with the NAMUR recommendation NE43, and supports configurable over- and under range limits

HART pass-through communication (AI880A)

Compatibility

Use with MTU: TU834, TU844, TU845 or TU854

Keying code: FD

Diagnostics

Front LED’s: F(ault), R(un), W(arning)

Supervision: Internal voltage, Field power input, Field power output per channel

Status indication of supervision : Module error, Module Warning, Channel error

FAQ

Q: What is the AI880A 3BSE039293R1?
A: It is a High Integrity Analog Input Module.

Q: What is the difference between AI880 and AI880A?
A: AI880A is an upgraded version of AI880, adding support for the HART protocol and optimizing the compatibility and long-term stability of internal electronic components. Other functions are basically the same as AI880, but AI880A is more suitable for integrating HART communication systems.

Q: Is an external resistor required of AI880A 3BSE039293R1?
A: Yes, AI880A requires an external shunt resistor (such as TY801, 250Ω) to be installed on an MTU (Modular Termination Unit) to function properly; otherwise, accurate current measurement and HART communication functions cannot be achieved.

Q: How to Check Price and Availability for AI880A 3BSE039293R1?
A: Please contact John Yang for sales at +86-18150117685 or request a quote.

Get a Free Quote