- Overview
- Specifications
- Description
- Applications
- Troubleshooting
- FAQ
- Recommended Products
Overview
Place of Origin: |
USA |
Brand Name: |
ICS TRIPLEX |
Model Number: |
TC-313-02 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Model |
TC-313-02 |
|
Product Type |
Local Expansion Cable Assembly |
|
Number of Ways |
3 Way |
|
Number of Elements |
3 |
|
Element Length |
SKT1 to SKT2 – 2 m |
|
Element Length |
SKT1 to SKT3 – 2.5 m |
|
Element Length |
SKT1 to SKT4 – 3 m |
|
Application |
From Expander Interface Module (T8311) to Triple Modular Redundant (TMR) Expander Processor (T8310) |
|
Maximum Working Voltage |
60 V |
|
Maximum Current per Channel |
2 A |
|
Cable Type |
LSZH (Low Smoke Zero Halogen) |
|
Cable Construction |
Cat 6 Plus, screened with LSZH sheath (TC-31X-02) or Cat 5e, screened UL Certified sheath (TC-31X-03) |
|
Connector Type |
96-way Type ‘C’ connector at each end |
|
Certifications |
IECEx, CCC Ex, CE |
|
Shielding |
Screened Cable |
|
Installation Type |
Local Expansion Connection |
|
Compatible System |
Trusted TMR System |
Description
The TC-313-02 Local Expansion Cable Assembly is used for reliable multi-point communication in industrial automation and safety control systems. It enables stable data exchange between controller interface modules and TMR expansion processor units, supporting distributed architecture in high-availability environments.
Applications
Large Petrochemical Refining Plants: Three-way topology supports TMR rooms with explosion-proof safety.
Offshore Oil Drilling Platforms: LSZH and shielding ensure SIS stability in marine corrosion.
Nuclear Power Control Facilities: Three-way branching enables real-time redundant ESD synchronization.
LNG Distribution Plants: Unequal lengths simplify cross-cabinet wiring layout.
Coal-to-Methanol Plants: IECEx shielding reduces ignition risk and EMI in hazardous zones.
Troubleshooting
Single-channel expansion processor outage: If SKT2, SKT3, or SKT4 fails, check 96-pin ‘C’ connector for looseness, bent pins, or contamination.
Multi-channel signal crosstalk: Inspect Cat 6 Plus shielding at branch points for damage and confirm cabinet grounding is secure.
Insulation resistance drop: In humid environments, check for moisture inside connectors and clean with electronic drying agent.
FAQ
Q: How many branch outputs does TC-313-02 provide?
A: Three-way design with 3 channels distributing signals to three endpoints.
Q: Are electrical parameters consistent across branches in TC-313-02?
A: Yes. Each channel supports 60V max voltage and 2A max current.
Q: Why is TC-313-02 suitable for hazardous environments?
A: Certified with IECEx, CCC Ex, and CE for high safety compliance.
Q: What are the installation requirements for the 96-pin connector on TC-313-02?
A: Ensure precise alignment, fully tighten screws, and secure strain relief on branches.
Q: Is TC-313-02 suitable when UL-certified sheath is required?
A: It uses Cat 6 Plus with LSZH sheath; UL version corresponds to Cat 5e-based alternative series.