Overview
Place of Origin: |
USA |
Brand Name: |
ICS TRIPLEX |
Model Number: |
TC-301-02-15M0 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Parameter |
Value |
|
Part Number |
TC-301-02-15M0 |
|
Part Name |
Communications Cable |
|
Cable Length |
15 m |
|
Maximum Length |
30 m |
|
Cable Type |
Cat 6 Plus shielded twisted pair |
|
Insulation Material |
Low smoke zero halogen (LSZH) |
|
Connection Start Point |
Expander Interface Adapter (T8312) |
|
Connection End Point |
Expander Processor (T8310) |
|
Rack End Interface (SKT2) |
96-pin C-type connector with dual-width protective shield and grounding braid |
|
Expansion End Interface (SKT1) |
12-pin Swiss LEMO high-precision self-locking connector |
Description
The TC-301-02-15M0 is an ultra-long, heavy-duty industrial Communications Cable masterfully engineered for expansive safety-critical distributed control system (DCS) architectures.
Applications
Large Chemical Plants: Long-distance routing between cabinets; LSZH prevents toxic fumes in fires.
Steel Smelting Plants: EMI shielding ensures stable long-range communication.
Nuclear Power Plants: Redundant DCS bus with strict fire safety compliance.
Modern Thermal Power Plants: Cross-floor direct control linking without relay risk.
Semiconductor Wafer Plants: Cleanroom-safe material with strong EMI resistance.
Troubleshooting
System handshake failure/Long bus disconnection: Check 12-pin LEMO lock “click”; reseat if loose.
Frequent CRC errors: Verify SKT2 ground braid tightly bonded to cabinet main earth.
Signal crosstalk/waveform distortion: Keep cable away from high-voltage power lines; reroute if needed.
FAQ
Q1: Will TC-301-02-15M0 suffer signal loss over its 15 m Cat 6 Plus link?
A: No. It is impedance-matched for up to 30 m, ensuring full-bandwidth stable transmission at 15 m.
Q2: Can TC-301-02-15M0 be cut and re-terminated to shorten to 12 m?
A: Absolutely not. Factory-terminated connectors would be damaged, breaking shielding and impedance balance.
Q3: What clearance is required for TC-301-02-15M0 SKT2 double-width hood?
A: Adequate slot spacing is required; compression is not allowed due to shielding and grounding structure.
Q4: What mechanical stress can TC-301-02-15M0 LEMO connector withstand?
A: High vibration and pull resistance; it remains locked under normal cable tension when engaged.
Q5: What happens if grounding braid of TC-301-02-15M0 is not connected?
A: EMI cannot be discharged, causing noise interference and possible data loss on the bus.