- Overview
- Specifications
- Description
- Applications
- Troubleshooting
- FAQ
- Recommended Products
Overview
Place of Origin: |
USA |
Brand Name: |
ICS TRIPLEX |
Model Number: |
TC-205-02-6M5 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Parameter |
Value |
|
Part Number |
TC-205-02-6M5 |
|
Part Name |
Trusted I/O Companion Slot Cable |
|
Cable Length |
6.5 m |
|
Cable Type |
Internal, 40-channel input to FTA |
|
Cable Description |
I/O companion slot internal cable for 40-channel input to FTA |
|
Maximum Working Voltage |
60 V |
|
Maximum Current |
2 A per channel |
|
With LED Indication |
False |
|
Cable Geometry |
Round |
|
Cable Insulation Type |
Low smoke zero halogen (LS0H) |
|
Halogen Free |
True |
|
Certifications |
ATEX; China CCC; CE; IECEx Scheme; UL Listed |
|
Connector Type (End A) |
96-pin C-type connector (base companion slot) |
|
Connector Type (End B) |
96-pin R-type connector (FTA termination panel) |
Description
The Trusted I/O Companion Slot Cable TC-205-02-6M5 is a high-reliability industrial internal wiring solution designed for safety instrumented systems and distributed control applications. It is used to transmit output signals from control modules to internal Field Termination Assemblies (FTA), ensuring stable and secure signal routing in complex automation architectures.
Applications
Petrochemical plants: Safe multi-channel transmission in explosive zones with ATEX/IECEx compliance.
Fine chemical plants: LS0H insulation reduces toxic gas release in fire conditions.
LNG plants: Efficient cabinet wiring for signal routing to FTA systems.
Thermal power plants: High-density input for turbine protection and relay control.
Offshore drilling platforms: UL/CE certified, resistant to humidity and salt corrosion.
Troubleshooting
Poor pin contact or signal loss: TC-205-02-6M5 uses high-density 96-pin connectors. Without LED indication (With LED indication: False), clean both ends and check for bent or recessed pins if faults occur.
Insulation damage causing shielding failure: Excess bending or sharp edges may damage the LS0H sheath. If insulation is damaged, do not repair; replace the entire cable.
FAQ
Q1: During commissioning, does TC-205-02-6M5 include LED indicators for 40-channel status monitoring?
A1: No. With LED indication is False, so no LED exists; status is checked via software or FTA.
Q2: What is the length and geometry of TC-205-02-6M5, and how does it help wiring?
A2: Cable length is 6.5 m. Geometry is Round, providing uniform bending and easier cable management.
Q3: What connector types are used in TC-205-02-6M5, and are they interchangeable?
A3: One end uses 96-pin C-type, the other 96-pin R-type; they are keyed and not interchangeable.
Q4: Does TC-205-02-6M5 meet halogen-free fire safety requirements?
A4: Yes. It uses LS0H insulation and is Halogen Free: True, with low smoke and no toxic gas release.
Q5: Is TC-205-02-6M5 certified for global explosive environments?
A5: Yes. It complies with ATEX/CE, IECEx, China CCC, and UL Listed standards.