- Overview
- Specifications
- Description
- Applications
- Common Faults and Troubleshooting
- FAQ
- Recommended Products
Overview
Place of Origin: |
USA |
Brand Name: |
ICS TRIPLEX |
Model Number: |
TC-011-02-1M5 |
Packaging Details: |
Original new Factory Sealed |
Delivery Time: |
5-7 days |
Payment Terms: |
T/T |
Supply Ability: |
In stock |
Specifications
|
Parameter |
Value |
|
Part Number |
TC-011-02-1M5 |
|
Part Name |
Fan Power Cable |
|
Cable Length |
1.5 m |
|
Rated Voltage |
24 V DC |
|
Maximum Working Voltage |
60 V |
|
Maximum Current |
20 A |
|
Insulation / Jacket Material |
LSZH (low smoke zero halogen), high flame-retardant industrial grade (IEC 60332-3 compliant) |
|
Connection Start Point |
T8292 MCB Power Distribution Unit |
|
Connection End Point |
T8270 Fan Assembly Rack |
|
Operating Temperature |
0°C to +60°C |
Description
The TC-011-02-1M5 Fan Power Cable is a heavy-duty industrial power solution designed to provide stable and reliable energy supply to critical cooling and ventilation systems in high-integrity automation environments.
Applications
Thermal Power Plants: Provide 24V fan power in hot, dusty turbine cabinets for continuous cooling.
Oil & Gas Refineries: Use flame-retardant LSZH jacket to limit fire spread in control rooms.
Offshore Oil Platforms: Supply reliable fan power in compact high-salt SIS cabinets.
Fertilizer Plants: Deliver stable high-current power to multi-fan control cabinets.
Semiconductor Plants: Ensure clean, non-toxic power for cooling in ultra-clean environments.
Common Faults and Troubleshooting
Rack Cooling Fan Stoppage / Undervoltage Warning: Often caused by loose connectors at T8292 breaker or fan end due to vibration. Stop system, recheck torque, and measure contact resistance.
Cable Sheath Damage from Friction: Occurs when cables rub against sharp rack edges, damaging LSZH sheath. Use protective tubing; replace cable if severely damaged.
Connector Overheating: Happens when multiple T8270 fans run near 20A limit. Check temperature, clean terminals, or redistribute/shunt load if needed.
FAQ
Q: What is the length and application of the TC-011-02-1M5 fan power cable?
A: It is 1.5 m long and connects the T8292 power distribution unit to the T8270 fan assembly for cooling power supply.
Q: What does “02” represent in the TC-011-02-1M5 cable specification?
A: It indicates LSZH high flame-retardant industrial jacket compliant with IEC 60332-3.
Q: What are the maximum voltage and current ratings of the TC-011-02-1M5 cable?
A: It supports up to 60 V maximum voltage and 20 A continuous current.
Q: Can the TC-011-02-1M5 cable operate safely in hot outdoor control cabinets?
A: Yes, it operates within 0°C to +60°C industrial temperature range.
Q: Can the TC-011-02-1M5 be used at 22 A load?
A: No, it is limited to 20 A; 22 A overload may cause overheating and insulation failure.