Siemens VXG41.1501 Acvatix Three-Port Valve DN 15, PN 16
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Size the circuit using DN 15 and kvs 4.0 m³/h.
- Select an SKD or SKB actuator when the tight-bypass leakage specification is required.
- Keep drinking-water service within 90 °C and observe the pressure-temperature limits.
- Provide an upstream strainer and avoid cavitation.
- Use ASZ6.6 stem heating for media below 0 °C.
- Allow service clearance and use stem gland 74 284 0047 0 for this .01 variant.
VXG41.1501 Acvatix Three-Port Valve DN 15, PN 16
A DN 15 bronze three-port valve with a 4.0 m³/h nominal flow coefficient, tight bypass and DVGW-tested drinking-water variant construction.
At a Glance
| Brand | Siemens |
|---|---|
| Model | VXG41.1501 |
| Product Type | Externally threaded three-port seat valve |
| Core Function | Modulates mixing or diverting water flow |
| Application | Heating, cooling and drinking-water control circuits |
DN 15 flow control
The nominal flow coefficient is 4.0 m³/h.
Tight bypass design
The .01 variant provides a tight bypass with the specified actuator combination.
Actuator selection
Select SAX, SKD or SKB actuation to suit the circuit and leakage requirements.
Product Overview
VXG41.1501 is a DN 15 Acvatix three-port seat valve for modulating water flow in mixing and diverting circuits.
The bronze body uses externally threaded flat-sealing connections, a stainless-steel seat, plug and stem, and a 20 mm nominal stroke; the .01 construction is intended for drinking-water applications within its specified temperature limit.
Key Functions
Mixing and diverting flow paths
Mixing directs flow from ports A and B to AB, while diverting directs flow from AB to A and B; mixing is the preferred application.
Modulating valve characteristic
The throughport is linear over the first 30% of stroke and equal-percentage over the remaining range, while the bypass characteristic is linear.
Tight-bypass water service
Use an SKD or SKB actuator to meet the specified bypass leakage rate for the .01 variant, and keep DVGW drinking-water service within 90 °C.
Official Specifications
| Nominal size | DN 15 |
|---|---|
| Nominal pressure class | PN 16 to ISO 7268 |
| Nominal flow coefficient kvs | 4.0 m³/h |
| Rangeability Sv | Greater than 50 |
| Nominal stroke | 20 mm |
| Throughport flow characteristic | Linear at 0–30% stroke; equal-percentage at 30–100%, ngl = 3 |
| Bypass flow characteristic | Linear over 0–100% stroke |
| Throughport leakage | 0–0.02% of kvs |
| Tight-bypass leakage | 0–0.02% of kvs with SKD or SKB actuator |
| Permissible water-medium temperature | −25 to +150 °C; subject to actuator and application limits |
| Maximum DVGW drinking-water application temperature | 90 °C |
| Valve body material | Bronze CuSn5Zn5Pb2 |
| Seat, plug and stem material | Stainless steel |
| Stem gland construction | Dezincification-free brass with silicon-free EPDM O-rings |
| External connection thread | G 1 B, flat-sealing, to ISO 228-1 |
| Face-to-face length L1 | 100 mm |
| Branch offset L2 and L3 | 50 mm each |
| Pipe centre to actuator installation edge H1 | 26 mm |
| Closed-valve height H2 | 122.5 mm |
| Valve weight | 1.30 kg |
Frequently Asked Questions
Which flow coefficient should be used when sizing VXG41.1501?
The nominal kvs value is 4.0 m³/h for the DN 15 valve.
How are the ports of VXG41.1501 arranged for mixing and diverting?
Mixing combines A and B into AB, while diverting splits flow from AB toward A and B.
Which actuator families maintain the tight bypass of VXG41.1501?
Use an SKD or SKB actuator to meet the specified tight-bypass leakage rate.
What temperature limit applies to VXG41.1501 in DVGW drinking-water service?
The maximum medium temperature for the DVGW drinking-water application is 90 °C.
Does VXG41.1501 require a stem heater for sub-zero media?
Media below 0 °C require the ASZ6.6 electric stem heater, rated 24 V AC and 30 W.
Are the actuator and union fittings included with VXG41.1501?
Valves, actuators and accessories are supplied separately, and DVGW-approved union fittings must be obtained separately for the drinking-water installation.
Which replacement stem gland belongs to VXG41.1501?
The replacement stem sealing gland order number is 74 284 0047 0.