Siemens SIRIUS 3RW5516-1HA15 3RW55 32 A Soft Starter
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Match the motor nameplate voltage, current and starting duty.
- Choose direct or inside-delta wiring deliberately.
- Provide the required 110 to 250 V AC control supply.
- Back up all three parameter sets and motor-protection values.
- Restore digital and analog I/O assignments.
- Apply temperature and altitude derating where required.
- Verify upstream protection, bypass arrangement and motor cable length.
Siemens · SIRIUS 3RW55
3RW5516-1HA15 SIRIUS 3RW55 32 A Soft Starter
Siemens 3RW5516-1HA15 is a SIRIUS 3RW55 digital soft starter rated 32 A at 40 degrees C for three-phase motors from 200 to 600 V AC. It provides adjustable voltage and torque ramps, current limiting, motor protection and programmable I/O.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 3RW5516-1HA15 |
| Product Type | Digital Soft Starter |
| Core Function | Controls the starting, stopping and protection of three-phase motors |
| Application or Compatible Series | SIRIUS 3RW55 motor-control applications from 200 to 600 V AC |
Motor Rating Match
Select direct or inside-delta wiring from the motor current, voltage, duty and ambient-temperature requirements.
Control Supply Check
Provide the 110 to 250 V AC control supply and preserve all programmed input and output assignments.
Parameter Backup
Record the active parameter set, ramp, torque, current-limit and protection values before replacement.
Product Overview
Siemens 3RW5516-1HA15 is a SIRIUS 3RW55 digital soft starter rated 32 A at 40 degrees C for three-phase motors from 200 to 600 V AC. It provides adjustable voltage and torque ramps, current limiting, motor protection and programmable I/O.
Controls starting with configurable voltage, torque, ramp and current-limit functions. Provides selectable stop ramps and motor-management functions for the connected load. Supervises current imbalance, ground faults, operating limits and programmable digital I/O.
Key Functions
Adjustable Motor Starting
Controls starting with configurable voltage, torque, ramp and current-limit functions.
Controlled Stopping
Provides selectable stop ramps and motor-management functions for the connected load.
Integrated Monitoring
Supervises current imbalance, ground faults, operating limits and programmable digital I/O.
Official Specifications
| Rated Operational Current at 40 degrees C | 32 A |
|---|---|
| Rated Operational Current at 50 degrees C | 28.4 A |
| Rated Operational Current at 60 degrees C | 26 A |
| Inside-Delta Current at 40 degrees C | 55.4 A |
| Operational Voltage Range | 200 to 600 V AC, -15% / +10% |
| Line Frequency | 50 or 60 Hz, +/-10% |
| Rated Motor Power at 400 V | 15 kW in direct connection |
| Starting Voltage | 20% to 100% |
| Starting and Stopping Ramp Time | 0 to 360 s |
| Starting and Stopping Torque | 10% to 100% |
| Torque Limit | 20% to 200% |
| Current Limit | 125% to 800% |
| Breakaway Pulse | 40% to 100% for 0 to 2 s |
| Parameter Sets | 3 |
| Control Supply | 110 to 250 V AC, 50/60 Hz |
| Control I/O | 4 digital inputs, 4 digital outputs and 1 analog output |
| Operating Temperature | -25 to +60 degrees C |
| Maximum Installation Altitude | 5000 m |
| Dimensions | 275 x 170 x 152 mm |
| Approximate Weight | 2.6 kg |
Frequently Asked Questions
Which motor current should I use to size 3RW5516-1HA15?
Use the rated motor current together with the wiring method, ambient temperature and required starting duty.
Can 3RW5516-1HA15 be connected inside the motor delta?
Yes, inside-delta operation is available when the motor terminals and project wiring support that connection.
What control supply is required for 3RW5516-1HA15?
Provide 110 to 250 V AC at 50 or 60 Hz.
How many parameter sets are available in 3RW5516-1HA15?
Three parameter sets can be retained for different operating requirements.
Can I adjust the current limit on 3RW5516-1HA15?
Yes, the current limit can be set from 125% to 800% of the applicable reference current.
Which settings should I back up before replacing 3RW5516-1HA15?
Record ramp times, starting voltage, torque limits, current limit, motor protection and every programmable I/O assignment.
What cabinet conditions apply to 3RW5516-1HA15?
Keep the ambient between -25 and +60 degrees C and apply the required derating for temperature and altitude.