Siemens SIMATIC S7-400 6ES7407-0KA01-0AA0 PS 407 10 A Power Supply
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use in a supported SIMATIC S7-400 rack.
- Match the KA01 10 A rating and two-slot form factor.
- Keep AC or DC input within the applicable permissible range.
- Calculate both 5.1 V and 24 V rack loads.
- Provide protective earth and the specified conductor size.
- Ensure the upstream protection tolerates the input inrush.
- Confirm cabinet ventilation and rack slot allocation.
Siemens · SIMATIC S7-400
6ES7407-0KA01-0AA0 PS 407 10 A Power Supply Module
Siemens 6ES7407-0KA01-0AA0 is the SIMATIC S7-400 PS 407 10 A rack power supply. It accepts wide-range AC or DC input and provides regulated 5.1 V and 24 V outputs for the S7-400 backplane.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7407-0KA01-0AA0 |
| Product Type | SIMATIC S7-400 Rack Power Supply |
| Core Function | Converts AC or DC plant power into regulated S7-400 backplane voltages |
| Application or Compatible Series | SIMATIC S7-400 central and expansion racks |
Exact KA01 Variant
Match the 10 A PS 407 article number and do not substitute another output rating or input family.
Rack Load Calculation
Add the 5 V and 24 V demand of every installed S7-400 module before selecting the supply.
Input and Grounding
Verify AC or DC input, protective earth, conductor size, inrush capability and cabinet protection.
Product Overview
Siemens 6ES7407-0KA01-0AA0 is the SIMATIC S7-400 PS 407 10 A rack power supply. It accepts wide-range AC or DC input and provides regulated 5.1 V and 24 V outputs for the S7-400 backplane.
Operates from common 120 or 230 V AC and 110 or 230 V DC plant supplies. Provides up to 10 A on the regulated 5.1 V rail for S7-400 rack electronics. Uses primary-to-secondary isolation, protective-earth construction and regulated rack outputs.
Key Functions
Wide-Range Input
Operates from common 120 or 230 V AC and 110 or 230 V DC plant supplies.
High-Current Backplane Output
Provides up to 10 A on the regulated 5.1 V rail for S7-400 rack electronics.
Isolated Protected Supply
Uses primary-to-secondary isolation, protective-earth construction and regulated rack outputs.
Official Specifications
| Nominal AC Input | 120 or 230 V AC |
|---|---|
| Nominal DC Input | 110 or 230 V DC |
| Permissible AC Input Range | 85 to 264 V AC |
| Permissible DC Input Range | 88 to 300 V DC |
| Line Frequency | 47 to 63 Hz |
| Input Current at 120 V AC | 0.9 A |
| Input Current at 230 V AC | 0.5 A |
| Input Current at 110 V DC | 1.0 A |
| Input Current at 230 V DC | 0.5 A |
| Rated Output Voltages | 5.1 V DC and 24 V DC |
| Maximum 5.1 V Output Current | 10 A |
| Maximum 24 V Output Current | 1 A |
| Leakage Current | Less than 3.5 mA |
| Protection Class | Class I with protective conductor |
| Overvoltage Category | II |
| Pollution Degree | 2 |
| Cable Connection | 3 x 1.5 mm2 conductors with end sleeves; 3 to 9 mm cable diameter |
| Dimensions | 50 x 290 x 217 mm |
| Approximate Weight | 1.36 kg |
| Required Rack Width | Two standard S7-400 slots |
Frequently Asked Questions
Which input supplies can feed 6ES7407-0KA01-0AA0?
Use 120 or 230 V AC, or 110 or 230 V DC, while staying within the specified wide input ranges.
How much 5 V rack current can 6ES7407-0KA01-0AA0 provide?
The regulated 5.1 V backplane output is rated for up to 10 A.
How much 24 V rack current is available from 6ES7407-0KA01-0AA0?
The 24 V backplane output is rated for up to 1 A.
What cable should I terminate on 6ES7407-0KA01-0AA0?
Use three 1.5 mm2 conductors with end sleeves and an overall cable diameter from 3 to 9 mm.
Does 6ES7407-0KA01-0AA0 require protective earth?
Yes, it is Class I equipment and must be connected to the protective conductor.
How much rack width does 6ES7407-0KA01-0AA0 occupy?
The 50 mm-wide module occupies two standard S7-400 slots.
What should I calculate before replacing 6ES7407-0KA01-0AA0?
Check the AC or DC input, inrush capacity, 5 V and 24 V load budget, slot width, grounding and cable termination.