- Use in a supported SIMATIC S7-400 rack.
- Match the KA01 10 A rating and two-slot form factor.
- Keep AC or DC input within the applicable permissible range.
- Calculate both 5.1 V and 24 V rack loads.
- Provide protective earth and the specified conductor size.
- Ensure the upstream protection tolerates the input inrush.
- Confirm cabinet ventilation and rack slot allocation.
SIEMENS · SIMATIC S7-400
6ES7407-0KA01-0AA0 PS 407 10 A Power Supply Module
Siemens 6ES7407-0KA01-0AA0 is the SIMATIC S7-400 PS 407 10 A rack power supply. It accepts wide-range AC or DC input and provides regulated 5.1 V and 24 V outputs for the S7-400 backplane.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | 6ES7407-0KA01-0AA0 |
| Typus Producti | SIMATIC S7-400 Rack Power Supply |
| Functio principalis | Converts AC or DC plant power into regulated S7-400 backplane voltages |
| Applicatio vel series compatibiles | SIMATIC S7-400 central and expansion racks |
Exact KA01 Variant
Match the 10 A PS 407 article number and do not substitute another output rating or input family.
Rack Load Calculation
Addere demandam 5 V et 24 V uniuscuiusque moduli S7-400 installati antequam electio suppetiae fiat.
Ingressus et Terrae Connectio
Verificare ingressum AC vel DC, terram protectricem, magnitudinem conductorum, capacitatem ad impetum initialem et protectionem armarii.
Product Overview
Siemens 6ES7407-0KA01-0AA0 is the SIMATIC S7-400 PS 407 10 A rack power supply. It accepts wide-range AC or DC input and provides regulated 5.1 V and 24 V outputs for the S7-400 backplane.
Operatur ex communibus suppletis plantarum 120 vel 230 V AC et 110 vel 230 V DC. Praebet usque ad 10 A in regula 5,1 V pro electronicis catenae S7-400. Utitur isolatione primaria-ad-secundariam, constructione cum terra protectrice et regulatis outputibus catenae.
Key Functions
Introductio lati campi
Operatur ex communibus suppletis plantarum 120 vel 230 V AC et 110 vel 230 V DC.
Output Planum Posticum Altocurrentiale
Praebet usque ad 10 A in regula 5,1 V pro electronicis catenae S7-400.
Supples Isolata et Protecta
Utitur isolatione primaria-ad-secundariam, constructione cum terra protectrice et regulatis outputibus catenae.
Official Specifications
| Nominale AC Ingang | 120 of 230 V AC |
|---|---|
| Nominale DC Ingang | 110 aut 230 V DC |
| Permissible AC Input Range | 85 ad 264 V AC |
| Permissibilis ambitus ingressus DC | 88 usque ad 300 V DC |
| Frequentia Lineae | 47 ad 63 Hz |
| Ingressus currentis ad 120 V AC | 0.9 A |
| Ingressus currentis ad 230 V AC | 0,5 A |
| Ingressus currentis ad 110 V DC | 1,0 A |
| Ingressus currentis ad 230 V DC | 0,5 A |
| Nominales Exirens Tensiones | 5,1 V DC et 24 V DC |
| Maximus 5,1 V egreditur currentis | 10 A |
| Maximus 24 V egreditur currentis | 1 A |
| Current Leakage | Minus quam 3,5 mA |
| Classis Protectionis | Classis I cum conductore protectivo |
| Categoria Super Voltae | II |
| Gradus Contaminations | 2 |
| Connexio Funis | 3 × 1,5 mm² conductores cum manicis terminalibus; diametrum cavi a 3 usque ad 9 mm |
| Dimensiones | 50 x 290 x 217 mm |
| Pondus Approximatum | 1,36 kg |
| Lata necessaria arcae | Duo loci standardis S7-400 |
Quaestiones Frequenter Rogatae
Quae alimenta intrantia 6ES7407-0KA01-0AA0 alere possunt?
Utere 120 vel 230 V AC, aut 110 vel 230 V DC, dum intra specificatas latas fasces manes.
Quantum currentis 5 V in catena 6ES7407-0KA01-0AA0 praebere potest?
Excessus regulatus 5.1 V in dorso catenae ad 10 A usque certificatus est.
Quantum currentis 24 V in catena ab 6ES7407-0KA01-0AA0 haberi potest?
Excessus 24 V in dorso catenae ad 1 A usque certificatus est.
Quod calebitur in 6ES7407-0KA01-0AA0 terminandum est?
Utere tribus conductorum 1.5 mm2 cum manicis terminalibus et diametro totali calebi a 3 ad 9 mm.
Does 6ES7407-0KA01-0AA0 require protective earth?
Yes, it is Class I equipment and must be connected to the protective conductor.
How much rack width does 6ES7407-0KA01-0AA0 occupy?
The 50 mm-wide module occupies two standard S7-400 slots.
What should I calculate before replacing 6ES7407-0KA01-0AA0?
Check the AC or DC input, inrush capacity, 5 V and 24 V load budget, slot width, grounding and cable termination.