Siemens SIMATIC ET 200SP HA 6DL1132-6BH00-0PH1 DQ 16x24VDC/0.5A HA Digital Output Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Order the terminal block separately and select M1 for redundant operation.
- Budget up to 0.5 A per output and apply the aggregate current limit for the installation temperature.
- Configure diagnostic monitoring and CPU STOP reaction for the process.
SIEMENS SIMATIC ET 200SP HA • DIGITAL OUTPUT
6DL1132-6BH00-0PH1 DQ 16x24VDC/0.5A HA Digital Output Module
A 16-channel 24 V DC sourcing output module with channel diagnostics for ET 200SP HA.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6DL1132-6BH00-0PH1 |
| Product Type | Digital output module |
| Core Function | 16-channel 24 V DC load switching |
| Compatible Series | SIMATIC ET 200SP HA |
Sourcing Outputs
Sixteen digital outputs switch 24 V DC loads at up to 0.5 A per channel.
Channel Diagnostics
Short circuit and wire break can be monitored on individual channels.
Redundant Configuration
A paired module can use the M1 terminal block for I/O redundancy.
Product Overview
6DL1132-6BH00-0PH1 is the DQ 16x24VDC/0.5A HA digital output module for SIMATIC ET 200SP HA. Its sixteen sourcing channels drive 24 V DC loads and provide selectable diagnostic monitoring.
The module operates with H1 or M1 terminal blocks; the M1 type supports a two-module redundant arrangement. The terminal block is ordered separately, and PCS 7 V9.0 or later can configure this module.
Key Functions
Actuator Switching
Switches sixteen 24 V DC loads at a rated 0.5 A per channel.
Fault Reporting
Reports per-channel wire break and short-circuit conditions plus missing supply voltage.
Redundant Output Layout
Supports two identical modules on the M1 terminal block for redundant control.
Official Specifications
| Firmware Version | V1.0 |
|---|---|
| Terminal Block Types | H1 or M1 |
| Rated Supply Voltage | 24 V DC |
| Permissible Supply Range | 19.2–28.8 V DC |
| No-Load Current Consumption | 60 mA rated; 70 mA maximum |
| Maximum Address Space | 2 output bytes plus 2 QI bytes |
| Maximum Resistive-Load Switching Current | 0.5 A per channel |
| Maximum Lamp Load | 5 W |
| Load Resistance Range | 48 Ω to 12 kΩ |
| Short-Circuit Response Threshold | 0.7–1.3 A typical |
| Wire-Break Diagnostic Test Current | 0.7 mA |
| Typical Turn-On Delay | 50 µs with resistive load |
| Typical Turn-Off Delay | 100 µs with resistive load |
| Maximum Module Output Current at 70 °C | 3 A, horizontal installation |
| Maximum Shielded Cable Length | 1000 m |
| Maximum Unshielded Cable Length | 600 m |
| Tested Isolation | 1500 V DC for 1 min |
| Module Width | 22.5 mm |
Frequently Asked Questions
Which terminal block should I use with 6DL1132-6BH00-0PH1 for redundancy?
Use an M1 terminal block with two identical modules for a redundant arrangement.
Can I diagnose a broken output wire on 6DL1132-6BH00-0PH1?
The module supports channel-by-channel wire-break diagnostics using a 0.7 mA test current.
What load current can 6DL1132-6BH00-0PH1 switch on each channel?
Each channel can switch a resistive load of up to 0.5 A.
How should I configure 6DL1132-6BH00-0PH1 in PCS 7?
Use PCS 7 V9.0 or later to configure the module and its channel parameters.
Does 6DL1132-6BH00-0PH1 keep an output state after a CPU stop?
The configurable CPU STOP reaction can shut down the output or retain its last value.
How far can I run a shielded cable from 6DL1132-6BH00-0PH1?
The maximum shielded cable length is 1000 m.
What current limit applies to 6DL1132-6BH00-0PH1 at 70 °C?
For horizontal installation at 70 °C, the combined module output current is limited to 3 A.