- Order the matching CM IO connector module separately; the Siemens product listing identifies CM IO 6ES7194-4..00-0AA0.
- Use shielded signal cables with a maximum length of 30 m.
- For RTD(0) reference-junction compensation, use the specified Pt1000 M12 compensation connector with the CM IO 4×M12 arrangement.
- Type B thermocouples and the ±80 mV range do not use temperature compensation.
SIMATIC ET 200pro ANALOG INPUT
Siemens 6ES7144-4PF00-0AB0 4 AI TC High Feature Module
Four-channel thermocouple and low-level voltage acquisition for distributed ET 200pro I/O.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7144-4PF00-0AB0 |
| Product Type | 4 AI TC High Feature analog electronic module |
| Core Function | Four thermocouple or ±80 mV analog inputs |
| Compatible Series | SIMATIC ET 200pro |
Signal types
Nine thermocouple types and a ±80 mV voltage range.
Measurement setup
Selectable rejection, smoothing and reference-junction compensation.
Fault indication
Channel diagnostics and a red SF group-fault LED.
Product Overview
6ES7144-4PF00-0AB0 is a Siemens SIMATIC ET 200pro High Feature analog input electronics module with four channels for thermocouples or ±80 mV signals. It supports thermocouple types B, E, J, K, L, N, R, S and T.
The module provides configurable interference suppression and smoothing, reference-junction compensation options, and channel-level diagnostics for distributed temperature measurements.
Key Functions
Thermocouple and millivolt acquisition
Four channels measure the supported thermocouple types or the ±80 mV voltage range.
Reference-junction setup
Internal, fixed, dynamic and RTD(0) compensation choices support different installed thermocouple wiring methods.
Noise filtering and diagnostics
Selectable 10 Hz, 50 Hz or 60 Hz suppression and smoothing work alongside channel diagnostics and the red SF group-fault indicator.
Official Specifications
| Supply voltage | 24 V DC |
|---|---|
| Reverse-polarity protection | Yes |
| Typical backplane-bus current | 20 mA |
| Typical 1L+ supply current | 34 mA |
| Typical power loss | 0.8 W |
| Dimensions (W × H × D) | 45 × 130 × 35 mm |
| Approximate module weight | 150 g |
| Maximum shielded cable length | 30 m |
| Voltage-input resistance | 10 MΩ |
| Voltage-input destruction limit | 20 V |
| Measuring principle | Integrating |
| Selectable interference suppression | 10 Hz, 50 Hz, 60 Hz or off |
| Conversion time per channel | 102 ms at 10 Hz; 22 ms at 50 Hz; 19 ms at 60 Hz; 4.7 ms with suppression off |
| Digital resolution | 15 bits plus sign |
| Selectable smoothing | 1, 4, 16 or 64 times the module cycle time |
| Common-mode rejection | At least 85 dB |
| Series-mode rejection | At least 42 dB |
| Crosstalk between inputs | At most −90 dB |
| Basic error at 25 °C | ±0.1% of input range |
| Isolation test voltage | 500 V DC |
Frequently Asked Questions
Which thermocouple types can I connect to 6ES7144-4PF00-0AB0?
The module accepts types B, E, J, K, L, N, R, S and T.
Can I use 6ES7144-4PF00-0AB0 for a low-level voltage signal?
Yes, each input can be configured for the ±80 mV measuring range.
How should I compensate the cold junction when wiring 6ES7144-4PF00-0AB0?
Choose internal, fixed, dynamic or RTD(0) reference-junction compensation to suit the installed wiring.
What cable length can I use with 6ES7144-4PF00-0AB0?
Use shielded signal cable no longer than 30 m.
Can I adjust noise rejection on 6ES7144-4PF00-0AB0?
Yes, the module offers 10 Hz, 50 Hz and 60 Hz suppression settings, as well as an off setting.
Which connector module should I order with 6ES7144-4PF00-0AB0?
Order a compatible ET 200pro CM IO connector module separately for the installed wiring arrangement.
How can I identify a channel fault on 6ES7144-4PF00-0AB0?
The module supports channel diagnostics and signals a group fault through its red SF LED.