Siemens SIMATIC ET 200iS 6ES7151-2AA00-0AB0 IM 151-2 Interface Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Confirm the PROFIBUS-DP Ex i segment, station address and master configuration.
- Check that every electronic module is approved for the intended hazardous-area installation.
- Install the supplied power-bus termination module and test all diagnostic indicators.
6ES7151-2AA00-0AB0 IM 151-2 Interface Module
IM 151-2 interface module for connecting ET 200iS distributed I/O to intrinsically safe PROFIBUS-DP.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7151-2AA00-0AB0 |
| Product Type | IM 151-2 Interface Module |
| Core Function | Connects ET 200iS electronic modules to PROFIBUS-DP Ex i and manages station data exchange |
| Application / Compatible Series | SIMATIC ET 200iS distributed I/O stations in hazardous-area process applications |
Bus Connection
PROFIBUS-DP Ex i interface for ET 200iS
Address Capacity
128 bytes inputs and 128 bytes outputs
Included Hardware
Power-bus termination module
Product Overview
Siemens 6ES7151-2AA00-0AB0 is the IM 151-2 interface module for connecting an ET 200iS distributed I/O station to PROFIBUS-DP Ex i.
The module processes data for the installed electronic modules, provides switch-based station addressing and supports up to 128 bytes of input and 128 bytes of output data.
Diagnostic LEDs report bus fault, group fault and 24 V supply status, while the supplied power-bus termination module completes the station assembly.
Key Functions
Intrinsically Safe PROFIBUS Interface
Connects ET 200iS station electronics to PROFIBUS-DP Ex i.
Distributed I/O Data Handling
Transfers up to 128 bytes of inputs and 128 bytes of outputs for the inserted modules.
Station Diagnostics
Provides bus-fault, group-fault and supply-voltage LED indications with diagnostic alarm support.
Official Specifications
| Product Type | IM 151-2 interface module |
|---|---|
| Distributed I/O System | SIMATIC ET 200iS |
| Fieldbus Interface | PROFIBUS-DP Ex i |
| Bus Protocol | PROFIBUS DP |
| Input Address Area | 128 bytes maximum |
| Output Address Area | 128 bytes maximum |
| Station Address Setting | Hardware switch |
| SYNC Capability | Supported |
| FREEZE Capability | Supported |
| Direct Data Exchange | Supported as slave-to-slave publisher |
| Diagnostic Alarms | Supported |
| Acyclic Parameter Access | Supported |
| Diagnostic LEDs | BF red, SF red and 24 V green |
| Isolation Test Voltage | 500 V DC |
| Hazardous-Area Protection | II 2 G EEx ib IIC T4 |
| Ambient Temperature for Ex Rating | -20 to 60 °C |
| Dimensions | 30 × 81 × 76 mm |
| Approximate Weight | 80 g |
| Included Component | Power-bus termination module |
Frequently Asked Questions
Which station family accepts 6ES7151-2AA00-0AB0?
It is designed for the SIMATIC ET 200iS distributed I/O platform and its approved electronic modules.
How is the PROFIBUS address set on 6ES7151-2AA00-0AB0?
Set the station address with the hardware switch before the station is placed into service.
What process-image capacity does 6ES7151-2AA00-0AB0 provide?
The interface handles up to 128 bytes of input data and 128 bytes of output data.
Which diagnostics are available on 6ES7151-2AA00-0AB0?
Red indicators show bus and group faults, while a green indicator confirms the 24 V supply status.
Can 6ES7151-2AA00-0AB0 exchange data directly with another slave?
Slave-to-slave direct data exchange is supported when the module is configured as the publisher.
What happens when the ET 200iS supply feeding 6ES7151-2AA00-0AB0 is switched off?
Removing the 24 V supply at the TM-PS terminal module also switches off the interface module.
What must be checked when installing 6ES7151-2AA00-0AB0 in a hazardous area?
Use only the approved ET 200iS components and preserve the PROFIBUS-DP Ex i, temperature and intrinsic-safety conditions.