Siemens • APOGEE PXC Compact
PXC16.2-E.A APOGEE PXC Compact 16-Point BACnet/IP Automation Station
The PXC Compact automation station provides sixteen field points and BACnet/IP automation-level networking for building control applications.
At a Glance
| Brand | Siemens |
|---|---|
| Model | PXC16.2-E.A |
| Product Type | Compact building automation station |
| Core Function | Controls sixteen field points and communicates on a BACnet/IP automation-level network |
| Application or Compatible Series | APOGEE and compatible Siemens building automation systems using BACnet/IP |
Exact Identification
Match PXC16.2-E.A character by character and confirm the complete APOGEE PXC Compact 16-Point BACnet/IP Automation Station designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
The PXC Compact automation station provides sixteen field points and BACnet/IP automation-level networking for building control applications.
The controller integrates sixteen field point terminations in one automation station. Ethernet communication connects the station to the automation-level network. The PXC Compact family exchanges control information with other field panels and workstations on the configured network.
Key Functions
Compact Sixteen-Point Control
The controller integrates sixteen field point terminations in one automation station.
BACnet/IP Networking
Ethernet communication connects the station to the automation-level network.
Peer-to-Peer Operation
The PXC Compact family exchanges control information with other field panels and workstations on the configured network.
Official Specifications
| Processor and Clock Speed | Freescale MPC852T, 100 MHz |
|---|---|
| Installed Memory | 24 MB total: 16 MB SDRAM and 8 MB Flash ROM |
| Dimensions (L × W × D) | 272 × 150 × 62 mm (10.7 × 5.9 × 2.45 in) |
| SDRAM Backup | 180 accumulated days; field-replaceable AA (LR6) 1.5 V alkaline battery |
| Real-Time Clock Backup | 10 years; BR2032 3 V lithium coin cell |
| Analog Input Resolution | 16-bit A/D conversion |
| Analog Output Resolution | 10-bit D/A conversion |
| HMI Serial Interface | RS-232, 1,200 bps to 115.2 kbps |
| Power Requirement | 24 Vac ±20%, 50/60 Hz |
| Maximum Power Consumption | 18 VA at 24 Vac |
| Digital Output Relay Rating | 110/220 V, 4 A resistive, Form C |
| Universal Analog Voltage Input | 0–10 Vdc |
| Universal Analog Current Input | 4–20 mA |
| Supported Resistance Sensors | 1 kΩ Ni RTD; 1 kΩ Pt RTD (α 0.00375 or 0.00385); 10 kΩ NTC Type 2/3; 100 kΩ NTC Type 2 |
| Pulse Accumulator Frequency | Up to 20 Hz on universal input points |
| Analog Output Range | 0–10 Vdc |
| Ambient Operating Temperature | 0 to 50 °C (32 to 122 °F) |
| Shipping and Storage Temperature | −25 to 70 °C (−13 to 158 °F) |
| Relative Humidity | 5–95% RH, non-condensing |
| Mounting Surface | Direct equipment mount, building wall or structural member |
Frequently Asked Questions
How many field points are provided by PXC16.2-E.A?
The compact controller provides sixteen point terminations.
Which automation network is used by PXC16.2-E.A?
Use the configured BACnet/IP automation-level Ethernet network.
Can PXC16.2-E.A exchange data directly with peer field panels?
Yes; peer-to-peer communication is supported on the configured automation-level network.
What should be backed up before replacing PXC16.2-E.A?
Save the controller database, BACnet identity, IP settings, point configuration, schedules and trend data.
How should the field wiring of PXC16.2-E.A be documented?
Label every point, common, power connection and network cable before disconnecting the controller.
What network conflicts must be avoided with PXC16.2-E.A?
Assign the validated IP settings and BACnet device identity without duplicating an active controller.
What should I test after installing PXC16.2-E.A?
Verify power, network communication, all sixteen field points, control programs, alarms, schedules and trends.
Compatibility & Ordering Notes
Compatibility Checklist
- Use it in the validated APOGEE BACnet/IP architecture.
- Preserve the controller database and unique BACnet network identity.
- Match all sixteen field terminations to the recorded point schedule.