Siemens APOGEE PXC Compact Statio Automationis 16-Puncta BACnet/IP PXC16.2-E.A
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Inscriptio electronica: [email protected]
whatsapp: +86-18150117685
- Conspectus
- Product Overview
- Key Functions
- Official Specifications
- Quaestiones Frequenter Rogatae
- Compatibility & Ordering Notes
- Hot Selling Models
- Producta commendata
Conspectus
Siemens • APOGEE PXC Compact
PXC16.2-E.A APOGEE PXC Compact 16-Punctum BACnet/IP Automatio-Statio
Statio automatio compacta PXC praebet sedecim puncta in campo et interreticulam automatio-nivelis BACnet/IP ad applicationes controlus aedificiorum.
Ad Primum Aspectum
| Nota | Siemens |
|---|---|
| Modellum | PXC16.2-E.A |
| Typus Producti | Statio automatio compacta aedificiorum |
| Functio principalis | Regit sedecim puncta in campo et communicat per interreticulam automatio-nivelis BACnet/IP |
| Applicatio vel series compatibiles | Systemata automatio aedificiorum APOGEE et compatibilia Siemens utentia BACnet/IP |
Identificatio exacta.
Adaequare PXC16.2-E.A littera pro littera et confirmare totam designationem APOGEE PXC Compact 16-Punctum BACnet/IP Automatio-Statio.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
Statio automatio compacta PXC praebet sedecim puncta in campo et interreticulam automatio-nivelis BACnet/IP ad applicationes controlus aedificiorum.
The controller integrates sixteen field point terminations in one automation station.
Key Functions
Compact Sixteen-Point Control
The controller integrates sixteen field point terminations in one automation station.
BACnet/IP Networking
Ethernet communication connects the station to the automation-level network.
Peer-to-Peer Operation
The PXC Compact family exchanges control information with other field panels and workstations on the configured network.
Official Specifications
| Processor and Clock Speed | Freescale MPC852T, 100 MHz |
|---|---|
| Memoria Installata | 24 MB total: 16 MB SDRAM and 8 MB Flash ROM |
| Mensurae (L × L × P) | 272 × 150 × 62 mm (10.7 × 5.9 × 2.45 in) |
| SDRAM Backup | 180 dies accumulatos; batería alcalina AA (LR6) de 1,5 V sustituible in situ |
| Reservatum Horologii Temporis Realis | 10 annos; pila de litio tipo moneda BR2032 de 3 V |
| Resolutio Ingressus Analogici | conversio A/D 16-bit |
| Resolutio Signi Analogici | conversione digital-analogic de 10 bit |
| Interfacs serialis HMI | RS-232, ab 1.200 bps usque ad 115,2 kbps |
| Requisitum Potentiae | 24 Vac ±20 %, 50/60 Hz |
| Consumptio electrica maxima | 18 VA ad 24 Vac |
| Rating del releo de output digital | 110/220 V, 4 A resistive, Forma C |
| Input analogic universal de voltamine | 0–10 VDC |
| Universalis Analogus Currentus Ingressus | 4–20 mA |
| Sensoria Resistentiae Admissibilia | 1 kΩ Ni RTD; 1 kΩ Pt RTD (α 0.00375 aut 0.00385); 10 kΩ NTC Typus 2/3; 100 kΩ NTC Typus 2 |
| Frequentia Accumulatoris Impulsuum | Usque ad 20 Hz in punctis ingressus universalibus |
| Intervalum Analogum Output | 0–10 VDC |
| Ambiens Operating Temperature | 0 ad 50 °C (32 ad 122 °F) |
| Shipping and Storage Temperature | −25 ad 70 °C (−13 ad 158 °F) |
| Humiditas relativa | 5–95 % RH, non condensans |
| Superficies Montandi | Montage directa in apparatu, pariete aedificii aut membro structurali |
Quaestiones Frequenter Rogatae
Quot puncta in campo praebet PXC16.2-E.A?
Controller compactus praebet sedecim terminations punctorum.
Quod automatio rete ab PXC16.2-E.A utitur?
Utere configurato BACnet/IP automation-level Ethernet rete.
Potestne PXC16.2-E.A data directe cum paribus field panelis commutare?
Ita; communicatio parum ad parum in configurato automation-level rete supportatur.
Quid ante substituendum PXC16.2-E.A servari debet?
Serva database controlleris, BACnet identitatem, IP parametres, puncti configurationem, schedulas et trend data.
Quomodo agri connexiones PXC16.2-E.A documentandae sunt?
Omnem punctum, communem, connexionem electricam et rete calembur antequam controller disiungitur notare oportet.
Quae rete conflictus cum PXC16.2-E.A vitandi sunt?
Validatos IP parametres et BACnet device identitatem sine duplicato activo controller assignare oportet.
Quid probare debeo post installationem PXC16.2-E.A?
Verifica potentiam, communicationem rete, omnes sedecim puncta in campo, programmatas regulandas, alarmitas, tempora et tendentias.
Compatibility & Ordering Notes
Index Compatibilitatis
- Utere in architectura APOGEE BACnet/IP conprobata.
- Serva databasem controlleris et unicum BACnet rete identitatem.
- Adaptato omnia sedecim terminatio in campo ad schedulam puncti annotatam.