Siemens PPM-1U32.BPF BACnet MS/TP Digital Point Pickup Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use the MS/TP version with a compatible BACnet building controller and set a suitable unique network address.
- Match the fixed-terminal digital variant and the thermistor or contact input types.
- Provide a Class 2 AC source and keep relay loads within the appropriate resistive or general-purpose rating.
- Set the baud rate by DIP switch and use the specified wiring and mounting arrangement with power disconnected.
PPM-1U32.BPF BACnet MS/TP Digital Point Pickup Module
Six-point digital PPM with one universal input, three dry-contact inputs, two relay outputs and fixed terminal blocks.
At a Glance
| Brand | Siemens |
|---|---|
| Model | PPM-1U32.BPF |
| Product Type | BACnet expansion I/O controller |
| Core Function | Remote building-system point acquisition and switching |
| Application | BACnet building-controller point expansion |
Distributed point acquisition
One universal input and three digital inputs collect remote building-system signals.
Relay output expansion
Two normally open relays switch the connected building-control loads.
BACnet network startup
DIP switches set the network address and communication rate, while device name and device ID are automatically populated.
Product Overview
PPM-1U32.BPF extends a building controller’s point count through a BACnet MS/TP network.
The fixed-terminal digital model combines a thermistor-or-contact universal input, pulse-capable digital inputs and relay outputs in an enclosed module with DIP-switch network setup.
Key Functions
Distributed point acquisition
One universal input and three digital inputs collect remote building-system signals.
Relay output expansion
Two normally open relays switch the connected building-control loads.
BACnet network startup
DIP switches set the network address and communication rate, while device name and device ID are automatically populated.
Official Specifications
| Power supply range | 19.2–28.8 V AC; 50/60 Hz; Class 2 source |
|---|---|
| Family power consumption | 4–7 VA |
| Universal input | 1; 10 kΩ Type II NTC thermistor or dry contact |
| Digital inputs | 3; dry contact or pulse accumulator |
| Digital outputs | 2 Form A normally open relays |
| Relay contact ratings | 24–240 V AC; 5 A resistive or 2 A general-purpose load |
| Terminal format | Fixed terminal blocks |
| Network interface | RS485 BACnet MS/TP; master or slave |
| Communication rates | 9600, 19200, 38400 or 76800 baud; default 19200 |
| Address selection | 8-bit DIP switch |
| Analog conversion resource | 12-bit A/D for supported analog sensing |
| Operating ambient | 0 to +50°C |
| Storage ambient | −40 to +70°C |
| Relative humidity | 5–95%, non-condensing |
| Dimensions | 154 × 114.4 × 34.5 mm |
| Maximum packaged weight | 0.8 lb including box |
| Mounting options | Electrical junction box, DIN rail or surface mounting |
| Local indicators | Power, communication and digital-output LEDs |
Frequently Asked Questions
Can I connect a 0–10 V transmitter to the universal input of PPM-1U32.BPF?
The universal input on this six-point digital model accepts a 10 kΩ Type II NTC thermistor or a dry contact rather than a 0–10 V signal.
Can I use local Hand-Off-Auto switches on PPM-1U32.BPF during checkout?
The BPF model has fixed terminals without the Hand-Off-Auto switches provided on the BPR digital version.
Can the three dedicated inputs of PPM-1U32.BPF count dry-contact pulses?
The three digital inputs can be used as dry-contact inputs or pulse accumulators.
Does PPM-1U32.BPF need a 24 V DC supply like many industrial I/O modules?
The module requires a Class 2 AC source in the 19.2–28.8 V range at 50 or 60 Hz.
Which network speed is active by default on PPM-1U32.BPF?
The default communication rate is 19200 baud, with 9600, 38400 and 76800 baud also selectable by DIP switch.
Do I need removable field terminal blocks when ordering PPM-1U32.BPF?
This BPF order number uses fixed terminal blocks.
Can PPM-1U32.BPF resume communication automatically after a power interruption?
The module recovers and resumes network communication after power returns without operator intervention.