Siemens 7KM2111-1BA00-3AA0 SENTRON PAC3200 Three-Phase Power Monitoring Device

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SENTRON PAC3200

7KM2111-1BA00-3AA0 SENTRON PAC3200 Three-Phase Power Monitoring Device

A DC-powered LCD meter with transformer current inputs, Modbus TCP and a programmable switching or pulse output.

At a Glance

Brand Siemens
Model 7KM2111-1BA00-3AA0
Product Type Panel power monitoring instrument
Core Function Measuring electrical power and energy
Application Stationary indoor electrical panels

Multivariable electrical measurement

RMS voltage and true-RMS current measurement accompany active and reactive power and energy functions.

Ethernet measurement access

The integrated Ethernet port supports Modbus TCP for the measured electrical values.

Configurable field signaling

One digital input and one switching or pulse output support the local monitoring arrangement.

Product Overview

7KM2111-1BA00-3AA0 measures voltage, current, power, frequency and energy in a three-phase electrical installation.

The extra-low-voltage DC supply is separate from the voltage measurement circuits, and the integrated Ethernet connection exposes measurements through Modbus TCP.

Ordering focus: Match the auxiliary DC supply, voltage circuit, 1 A or 5 A current-transformer secondary and required communication options.
Key Functions

Multivariable electrical measurement

RMS voltage and true-RMS current measurement accompany active and reactive power and energy functions.

Ethernet measurement access

The integrated Ethernet port supports Modbus TCP for the measured electrical values.

Configurable field signaling

One digital input and one switching or pulse output support the local monitoring arrangement.

Official Specifications
Auxiliary supply 22–65 V DC, ±10%
Measurement frequency 45–65 Hz with automatic line-frequency detection
Voltage measurement method RMS; sinusoidal or distorted waveform
Current measurement method True RMS
Nominal voltage inputs 500 V line-to-line; 289 V line-to-neutral
Voltage measuring ranges 70–600 V line-to-line; 40–346 V line-to-neutral
Rated current inputs 1 A or 5 A AC; 10–120% relative measurement range
Measurement categories CAT III for voltage and current; CAT II for digital signals
Measurement error limits Voltage ±0.3%; current ±0.2%
Active energy accuracy Class 0.5 to IEC 61557-12; class 0.5s to IEC 62053-22
Reactive energy accuracy Class 2 to IEC 61557-12 or IEC 62053-23
Ethernet data interface One 10 Mbit/s port with Modbus TCP
Digital I/O One digital input and one digital output
Digital-output limits 30 V DC maximum; 27 mA maximum high-state current; short-circuit proof
Pulse-output timing 30–500 ms pulse duration; maximum switching frequency 17 Hz
Display and controls 72 × 54 mm LCD with four keys
Front protection IP65
Operating environment −10 to +55 °C; maximum 95% RH at 25 °C without condensation
Installation altitude Up to 2,000 m
Dimensions and installation depth 96 × 96 × 56 mm; installation depth 51 mm
Frequently Asked Questions

Can I power 7KM2111-1BA00-3AA0 directly from a 230 V AC auxiliary supply?

This variant uses an extra-low-voltage DC supply rated 22–65 V DC with the stated tolerance.

Can I use either 1 A or 5 A current-transformer secondaries with 7KM2111-1BA00-3AA0?

The current inputs provide rated measurement choices of 1 A and 5 A AC.

Which protocol is available through the built-in network port of 7KM2111-1BA00-3AA0?

The integrated Ethernet interface supports Modbus TCP.

Does 7KM2111-1BA00-3AA0 measure distorted current waveforms?

The current measurement uses the true-RMS method.

Can the digital output of 7KM2111-1BA00-3AA0 produce energy pulses?

The digital output can be used as either a switching output or a pulse output.

Can I use 7KM2111-1BA00-3AA0 as an outdoor freestanding instrument?

The instrument is intended for stationary panel installation in closed indoor rooms.

Does the front IP65 rating of 7KM2111-1BA00-3AA0 remove the need for a suitable panel enclosure?

The stated IP65 protection applies to the front of the installed meter.

Compatibility & Ordering Notes
Before ordering 7KM2111-1BA00-3AA0: Match the auxiliary DC supply, voltage circuit, 1 A or 5 A current-transformer secondary and required communication options.

Before installation

  • Keep auxiliary DC power separate from the measured voltage circuit requirements.
  • Select and configure the correct current-transformer secondary rating.
  • Use the built-in Modbus TCP interface or the appropriate optional communication module for the project.
  • Install vertically in a suitable indoor panel and observe environmental and altitude limits.
Hot Selling Models
281-906
P1-32 + HI11-P1/P3/E
3RT1926-2EJ11
QP011000750551/707919 TB-P2/20273743
6ES5 308-3UA12 6ES5376-0AA11
7.648.131 L-227-4-01
4NC1121-0CE20
C12-K10G3/8
ABB 1SDA105025R1 KXT5HTC-3
GV2P02
7PA1010-2EA
6ES7151-1AA05-0AB0
10.02.02.00565/3
LRS-D-7-MIDI
3RB2016-2SB0 3RT1016-1BB41 3RT1916-1BB00

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.