- Overview
- Hot Selling Models
- Recommended Products
Overview
- Use the matching Design K arrangement and the corresponding insulating washer.
- Have qualified personnel isolate the converter and observe the DC-link discharge interval before work.
- Identify PUD and NUD before disconnecting the M4 Torx connections.
- Keep the resistor aligned, apply the specified mounting torque and refit connections and fastenings in reverse removal order.
6SY7000-0AD34 SIMOVERT MASTERDRIVES Pre-Charging Resistor
A pre-charging resistor for the Design K converter assembly, with a dedicated insulating washer and a specified mechanical replacement procedure.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SY7000-0AD34 |
| Product Type | Pre-charging resistor spare part |
| Core Function | Resistive element in the converter precharge circuit |
| Application | Design K converter maintenance |
Converter precharge circuit
The component serves the converter precharging arrangement.
Insulated mounting arrangement
A dedicated 6SY7000-0AD12 insulating washer accompanies the resistor installation.
Defined mechanical interface
The Design K arrangement uses M4 Torx connections and a specified resistor mounting torque.
Product Overview
6SY7000-0AD34 forms part of the precharge circuit in a SIMOVERT MASTERDRIVES Design K converter.
The associated insulating washer is ordered as 6SY7000-0AD12; the Design K service arrangement places the precharge resistors beside the TDB board and connects them at PUD and NUD.
Key Functions
Converter precharge circuit
The component serves the converter precharging arrangement.
Insulated mounting arrangement
A dedicated 6SY7000-0AD12 insulating washer accompanies the resistor installation.
Defined mechanical interface
The Design K arrangement uses M4 Torx connections and a specified resistor mounting torque.
Official Specifications
| Electrical connection hardware | PUD and NUD connections with M4 Torx fasteners, Design K arrangement |
|---|---|
| Resistor mounting torque | 20 N·m ±10%, Design K replacement procedure |
| Resistor element designation | AB85301M008 |
| Nominal resistance | 15 Ω |
| Resistance tolerance | ±20% |
| Net weight | 0.18 kg |
| Mounting insulation | Insulating washer 6SY7000-0AD12, Design K assembly |
| RoHS substance restrictions | Compliant |
Frequently Asked Questions
Which insulating washer is associated with 6SY7000-0AD34?
The corresponding insulating washer is 6SY7000-0AD12.
Where is 6SY7000-0AD34 located in the Design K precharge arrangement?
The precharge resistors sit to the right of the TDB board in the rectifier section.
Which connections must be disconnected when removing 6SY7000-0AD34?
Disconnect the PUD and NUD connections before detaching the resistor.
Which connection fasteners are used for 6SY7000-0AD34 in the Design K assembly?
The PUD and NUD connections use M4 Torx fasteners.
What mounting torque applies when fitting 6SY7000-0AD34?
The resistor mounting torque is 20 N·m with a tolerance of ±10%.
Can I tilt 6SY7000-0AD34 while fitting it into the assembly?
Keep the resistor aligned without tilting it during installation.
Can I start replacing 6SY7000-0AD34 as soon as the converter is powered down?
Wait at least five minutes for the DC-link discharge interval before working on the unit or DC-link terminals.