siemens 6sx7010 0ff05 simovert masterdrives cbp2 profibus retrofit kit-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6SX7010-0FF05 SIMOVERT MASTERDRIVES CBP2 PROFIBUS Retrofit Kit

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIMOVERT MASTERDRIVES

6SX7010-0FF05 SIMOVERT MASTERDRIVES CBP2 PROFIBUS Retrofit Kit

A CBP2 retrofit kit with an isolated X448 interface, transfer rates up to 12 Mbaud and separate board, host and bus indicators.

At a Glance

Brand Siemens
Model 6SX7010-0FF05
Product Type Drive communication retrofit kit
Core Function Adding PROFIBUS drive-data exchange
Application MASTERDRIVES Motion Control option systems

Add the CBP2 communication option

The retrofit kit provides the CBP2 board for a compatible MASTERDRIVES drive rather than a bare spare board.

Connect an isolated bus interface

The nine-pin X448 socket carries the PROFIBUS RS485 connection and an isolated supply for termination or an optical link plug.

Separate communication status checks

Red, yellow and green LEDs distinguish board operation, basic-unit data exchange and useful PROFIBUS traffic.

Product Overview

6SX7010-0FF05 is the retrofit-kit ordering form of the CBP2 PROFIBUS option. It equips a compatible drive with an isolated RS485 connection for exchanging process data with the automation network.

The kit form supplies the board together with connectors and short instructions, while required adapter boards and the LBA are separate items. Installation planning must account for the drive construction, available option slot and connector clearance.

Ordering focus: Choose the retrofit-kit form, then match the drive option slot, required adapters, PROFIBUS connector and bus-address configuration.
Key Functions

Add the CBP2 communication option

The retrofit kit provides the CBP2 board for a compatible MASTERDRIVES drive rather than a bare spare board.

Connect an isolated bus interface

The nine-pin X448 socket carries the PROFIBUS RS485 connection and an isolated supply for termination or an optical link plug.

Separate communication status checks

Red, yellow and green LEDs distinguish board operation, basic-unit data exchange and useful PROFIBUS traffic.

Official Specifications
Bus connector X448, isolated 9-pin female D-sub
Maximum transmission rate 12 Mbaud
Internal electronics supply 5 V ±5%; maximum 600 mA from the basic unit
Isolated connector supply 5 V ±10%; maximum 100 mA at X448 pin 6
RS485 signal pins Pin 3: B/P; pin 8: A/N
Signal reference and shield pins Pin 5: DGND; pin 1: shield/ground
Internal bus termination None
Status indications Red board-operation LED; yellow host-data LED; green PROFIBUS-data LED
Cooling Natural air cooling
Operating temperature 0–70 °C
Storage and transport temperature −25 to +70 °C
Humidity limits 85% RH during operation without condensation; 95% during storage/transport
Climate class 3K3 to DIN IEC 721-3-3
Pollution degree 2 to IEC 664-1
Stationary vibration resistance 0.15 mm at 10–58 Hz; 19.6 m/s² above 58–500 Hz
Frequently Asked Questions

Does 6SX7010-0FF05 include the same items as the bare CBP2 spare board?

The retrofit-kit form includes the board, connectors and short instructions, while the bare spare board excludes connectors and documentation.

Are adapter boards and the LBA included with 6SX7010-0FF05?

Adapter boards and the local bus adapter are separate items.

Do I need to enable a built-in terminating resistor on 6SX7010-0FF05?

The CBP2 has no internal bus termination, so termination is provided through the external PROFIBUS connector.

Which cable shields should I bond when fitting 6SX7010-0FF05?

Bond the cable shield over a large surface area at both ends.

What should I check after switching on a drive fitted with 6SX7010-0FF05?

After the automatic self-test, register the new board if required and assign its bus address.

Can 6SX7010-0FF05 occupy a slot already needed by an encoder board?

The encoder board requires slot C, so the option arrangement must reserve that position for the encoder when used.

What does a steady green LED on 6SX7010-0FF05 indicate?

A static green indication signals an abnormal PROFIBUS data state, including a disconnected or defective bus cable.

Compatibility & Ordering Notes
Before ordering 6SX7010-0FF05: Choose the retrofit-kit form, then match the drive option slot, required adapters, PROFIBUS connector and bus-address configuration.

Before installation

  • Order the required adapter board and LBA separately when the drive construction needs them.
  • Use PROFIBUS connectors with enabled terminating resistors only at the first and last nodes.
  • Do not fit 90° PROFIBUS connectors in Compact-unit slots E or G.
  • Allow for possible 90° connector interference in Compact PLUS slots A and B and the optical-link restriction on Compact types 1 and 2.
Hot Selling Models
3RV2011-1EA20
CKA03VS
10-PE 3044173
7NG4021-1NN0
IE5207
3RV2 011-1JA10
GB2CB09 021466
4AV2102-2AB
DDC70
1740025-1 RJ45
1827414303 EX-03
1020100000
ABB AF09-30-22-13 1SBL137001R1322
6ES7392-1BM01-0AA0
GB2CB09 021468