Siemens 6SX7010-0FF05 SIMOVERT MASTERDRIVES CBP2 PROFIBUS Retrofit Kit
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Order the required adapter board and LBA separately when the drive construction needs them.
- Use PROFIBUS connectors with enabled terminating resistors only at the first and last nodes.
- Do not fit 90° PROFIBUS connectors in Compact-unit slots E or G.
- Allow for possible 90° connector interference in Compact PLUS slots A and B and the optical-link restriction on Compact types 1 and 2.
6SX7010-0FF05 SIMOVERT MASTERDRIVES CBP2 PROFIBUS Retrofit Kit
A CBP2 retrofit kit with an isolated X448 interface, transfer rates up to 12 Mbaud and separate board, host and bus indicators.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SX7010-0FF05 |
| Product Type | Drive communication retrofit kit |
| Core Function | Adding PROFIBUS drive-data exchange |
| Application | MASTERDRIVES Motion Control option systems |
Add the CBP2 communication option
The retrofit kit provides the CBP2 board for a compatible MASTERDRIVES drive rather than a bare spare board.
Connect an isolated bus interface
The nine-pin X448 socket carries the PROFIBUS RS485 connection and an isolated supply for termination or an optical link plug.
Separate communication status checks
Red, yellow and green LEDs distinguish board operation, basic-unit data exchange and useful PROFIBUS traffic.
Product Overview
6SX7010-0FF05 is the retrofit-kit ordering form of the CBP2 PROFIBUS option. It equips a compatible drive with an isolated RS485 connection for exchanging process data with the automation network.
The kit form supplies the board together with connectors and short instructions, while required adapter boards and the LBA are separate items. Installation planning must account for the drive construction, available option slot and connector clearance.
Key Functions
Add the CBP2 communication option
The retrofit kit provides the CBP2 board for a compatible MASTERDRIVES drive rather than a bare spare board.
Connect an isolated bus interface
The nine-pin X448 socket carries the PROFIBUS RS485 connection and an isolated supply for termination or an optical link plug.
Separate communication status checks
Red, yellow and green LEDs distinguish board operation, basic-unit data exchange and useful PROFIBUS traffic.
Official Specifications
| Bus connector | X448, isolated 9-pin female D-sub |
|---|---|
| Maximum transmission rate | 12 Mbaud |
| Internal electronics supply | 5 V ±5%; maximum 600 mA from the basic unit |
| Isolated connector supply | 5 V ±10%; maximum 100 mA at X448 pin 6 |
| RS485 signal pins | Pin 3: B/P; pin 8: A/N |
| Signal reference and shield pins | Pin 5: DGND; pin 1: shield/ground |
| Internal bus termination | None |
| Status indications | Red board-operation LED; yellow host-data LED; green PROFIBUS-data LED |
| Cooling | Natural air cooling |
| Operating temperature | 0–70 °C |
| Storage and transport temperature | −25 to +70 °C |
| Humidity limits | 85% RH during operation without condensation; 95% during storage/transport |
| Climate class | 3K3 to DIN IEC 721-3-3 |
| Pollution degree | 2 to IEC 664-1 |
| Stationary vibration resistance | 0.15 mm at 10–58 Hz; 19.6 m/s² above 58–500 Hz |
Frequently Asked Questions
Does 6SX7010-0FF05 include the same items as the bare CBP2 spare board?
The retrofit-kit form includes the board, connectors and short instructions, while the bare spare board excludes connectors and documentation.
Are adapter boards and the LBA included with 6SX7010-0FF05?
Adapter boards and the local bus adapter are separate items.
Do I need to enable a built-in terminating resistor on 6SX7010-0FF05?
The CBP2 has no internal bus termination, so termination is provided through the external PROFIBUS connector.
Which cable shields should I bond when fitting 6SX7010-0FF05?
Bond the cable shield over a large surface area at both ends.
What should I check after switching on a drive fitted with 6SX7010-0FF05?
After the automatic self-test, register the new board if required and assign its bus address.
Can 6SX7010-0FF05 occupy a slot already needed by an encoder board?
The encoder board requires slot C, so the option arrangement must reserve that position for the encoder when used.
What does a steady green LED on 6SX7010-0FF05 indicate?
A static green indication signals an abnormal PROFIBUS data state, including a disconnected or defective bus cable.