Siemens SINAMICS S Smart Line Module Control Interface Board 6SL3353-6TG38-8CA3
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
Siemens · SINAMICS S120 Chassis
6SL3353-6TG38-8CA3 SINAMICS S Smart Line Module Control Interface Board
This SINAMICS S spare part is a replacement Control Interface Board for the 500 to 690 V, 50/60 Hz, 900 A Smart Line Module, with the service procedure specifying the matching control interface module and power-section electronics.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SL3353-6TG38-8CA3 |
| Product Type | Replacement Control Interface Board for a Smart Line Module |
| Core Function | Restores the control-interface function of the specified 900 A Smart Line Module power unit |
| Application or Compatible Series | Air-cooled SINAMICS S120 Smart Line Modules in the 500–690 V class |
Exact Identification
Match 6SL3353-6TG38-8CA3 character by character and confirm the complete SINAMICS S Smart Line Module Control Interface Board designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
This SINAMICS S spare part is a replacement Control Interface Board for the 500 to 690 V, 50/60 Hz, 900 A Smart Line Module, with the service procedure specifying the matching control interface module and power-section electronics.
The board is assigned to the 900 A Smart Line Module in the 500 to 690 V voltage class. The Siemens service matrix identifies the related CIM and power-section electronics for controlled replacement. Designed for the control interface of an air-cooled SINAMICS S120 chassis-format line module.
Key Functions
Model-Specific Power-Unit Match
The board is assigned to the 900 A Smart Line Module in the 500 to 690 V voltage class.
Defined Service Components
The Siemens service matrix identifies the related CIM and power-section electronics for controlled replacement.
Chassis Drive Integration
Designed for the control interface of an air-cooled SINAMICS S120 chassis-format line module.
Official Specifications
| Spare-Part Function | Replacement Control Interface Board |
|---|---|
| Drive Family | SINAMICS S120 |
| Parent Power Unit | Smart Line Module |
| Line Voltage Class | 500 to 690 V AC |
| Line Frequency | 50/60 Hz |
| Parent-Module Current Rating | 900 A |
| Cooling Format | Air-cooled chassis unit |
| Specified Control Interface Module | 6SL3350-6TK00-0EA0 |
| Specified Power-Section Electronics | 6SL3353-3AG38-8CA0 |
| Service Scope | Model-specific spare part |
| Installation Requirement | Electrostatic-discharge controlled service procedure |
Frequently Asked Questions
Which power unit is 6SL3353-6TG38-8CA3 assigned to?
It is assigned to the 900 A Smart Line Module in the 500 to 690 V class.
Can 6SL3353-6TG38-8CA3 be selected only by visual similarity?
No; match the complete article number and the installed line-module rating before service.
Which related CIM is specified with 6SL3353-6TG38-8CA3?
The service matrix specifies the control interface module ending in 0EA0 for this board.
What electrical condition is required before replacing 6SL3353-6TG38-8CA3?
Isolate the drive, wait for the DC link to discharge and confirm absence of voltage using the approved procedure.
How should 6SL3353-6TG38-8CA3 be handled during installation?
Use grounded electrostatic-discharge controls and avoid touching connector contacts or components.
What configuration should be preserved before replacing 6SL3353-6TG38-8CA3?
Back up the drive project, firmware information, parameter set and commissioning records.
What checks follow replacement of 6SL3353-6TG38-8CA3?
Verify connectors, auxiliary supplies, fan operation, diagnostics, parameter consistency and the authorized functional test.
Compatibility & Ordering Notes
Compatibility Checklist
- Use only with the exact Smart Line Module and service-component combination listed for this article number.
- Follow the SINAMICS chassis discharge, lockout and ESD procedure before opening the power unit.
- Restore and verify the approved drive parameter set before returning the converter to service.