siemens 6sl3244 0bb12 1fa0 sinamics g120 cu240e 2 pn control unit-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6SL3244-0BB12-1FA0 SINAMICS G120 CU240E-2 PN Control Unit

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SINAMICS G120

6SL3244-0BB12-1FA0 SINAMICS G120 CU240E-2 PN Control Unit

CU240E-2 PN with PROFINET and EtherNet/IP, six standard digital inputs, two relay outputs and a shared-input fail-safe channel.

At a Glance

Brand Siemens
Model 6SL3244-0BB12-1FA0
Product Type Drive control unit
Core Function Networked motor control and signal processing
Application Compatible G120 Power Module assemblies

Industrial Ethernet control

PROFINET and EtherNet/IP provide the stated network communication choices.

Flexible local signal allocation

Six standard digital inputs, differential analog/digital inputs, relay contacts and analog outputs support the control arrangement.

Encoderless motor-control modes

V/f, FCC, ECO, sensorless vector and encoderless torque control are supported.

Product Overview

6SL3244-0BB12-1FA0 provides networked drive control and local signal processing for a compatible SINAMICS G120 Power Module.

The Control Unit supports PROFINET or EtherNet/IP communication, differential analog inputs and non-isolated analog outputs, with two standard digital inputs used when configuring its single fail-safe input.

Ordering focus: Select the network protocol, Power Module, local I/O allocation and required fail-safe input arrangement.
Key Functions

Industrial Ethernet control

PROFINET and EtherNet/IP provide the stated network communication choices.

Flexible local signal allocation

Six standard digital inputs, differential analog/digital inputs, relay contacts and analog outputs support the control arrangement.

Encoderless motor-control modes

V/f, FCC, ECO, sensorless vector and encoderless torque control are supported.

Official Specifications
Power Module operating supply 24 V DC
External operating supply 20–29 V DC
Maximum supply current 0.50 A
Power loss 5.50 W
Network protocols PROFINET and EtherNet/IP
Standard digital inputs 6
Fail-safe input allocation 1 fail-safe input using 2 standard digital inputs
Digital switching thresholds 0 to 1: 11 V; 1 to 0: 5 V
Relay outputs 2 changeover relays
Analog/digital inputs 2 differential inputs
Analog outputs 2 non-isolated outputs
V/f modes Linear, square-law, parameterizable, FCC and ECO
Vector and torque modes Sensorless vector and encoderless torque control
Operating ambient −10 to +55°C
Storage ambient −40 to +70°C
Maximum operating humidity 95%
Signal conductor range 0.05–1.50 mm²; AWG 28–16
Enclosure protection IP20 / UL open type
Dimensions and weight 73 × 199 × 46 mm (W × H × D); 0.49 kg
Frequently Asked Questions

Can I use 6SL3244-0BB12-1FA0 on an EtherNet/IP-controlled machine?

The Control Unit supports EtherNet/IP as well as PROFINET communication.

Does the fail-safe input of 6SL3244-0BB12-1FA0 require additional dedicated terminals beyond the six standard inputs?

The single fail-safe input is formed using two of the standard digital inputs.

Can I switch two separate relay-controlled signals from 6SL3244-0BB12-1FA0?

The unit provides two changeover relay outputs.

Are the analog input channels of 6SL3244-0BB12-1FA0 differential?

The two analog/digital input channels use differential inputs.

Should I treat the analog outputs of 6SL3244-0BB12-1FA0 as isolated signals?

The two analog outputs are non-isolated.

What external DC supply range can power 6SL3244-0BB12-1FA0?

The permitted external supply range is twenty to twenty-nine volts DC.

Can I use an ECO V/f mode with 6SL3244-0BB12-1FA0?

The unit supports linear and square-law V/f ECO control.

Compatibility & Ordering Notes
Before ordering 6SL3244-0BB12-1FA0: Select the network protocol, Power Module, local I/O allocation and required fail-safe input arrangement.

Before installation

  • Match the G120 Power Module and select the intended network protocol.
  • Reserve the two standard inputs needed for the configured fail-safe input.
  • Observe the references of the differential inputs and non-isolated outputs.
  • Use the specified supply and signal-conductor limits in the protected cabinet installation.
Hot Selling Models
FR95XBKEX1C
3LD2264-1GP51
90609-3595 G/9.1311.050
7F.20.9.024.1020
852-112
Tele RNG 36
CXSM15-20
AT-GS910/8
8045649 8I/OM12-5P3F
558362
ADVU-32-30-PA
TN2P5PA12A 2376600001
3RX9307-0AA00
ABL8RPS24050
CS16/30

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.