Siemens 6SL3210-1PE13-2UL1 SINAMICS G120 PM240-2 Power Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Choose LO or HO duty before comparing motor current and overload demand.
- Respect the complete 300-second overload cycle rather than the brief peak value alone.
- Match the Control Unit and drive configuration to the required control method.
- Observe terminal conductor limits, cooling airflow and motor-cable restrictions.
6SL3210-1PE13-2UL1 SINAMICS G120 PM240-2 Power Module
A PM240-2 power section rated at 1.1 kW LO or 0.75 kW HO, with defined short-term overload cycles.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SL3210-1PE13-2UL1 |
| Product Type | Converter power module |
| Core Function | Power conversion for controlled motor operation |
| Application | FSA modular G120 drive systems |
Defined short-term overload
Separate LO and HO cycles provide different short-duration current margins.
Variable output frequency
The power section supports the output-frequency ranges used with the selected drive-control method.
Plug-in terminal connections
Screw terminal plugs separate incoming line and motor connections.
Product Overview
6SL3210-1PE13-2UL1 forms the motor-power section of a modular G120 converter.
The FSA assembly supports different continuous and short-term current requirements, making duty selection central to matching the motor and application.
Key Functions
Defined short-term overload
Separate LO and HO cycles provide different short-duration current margins.
Variable output frequency
The power section supports the output-frequency ranges used with the selected drive-control method.
Plug-in terminal connections
Screw terminal plugs separate incoming line and motor connections.
Official Specifications
| Line supply | 3-phase AC, 380–480 V ±10%; 47–63 Hz |
|---|---|
| Input current by duty | LO: 4.1 A; HO: 3.3 A |
| Rated output power | LO: 1.10 kW; HO: 0.75 kW |
| Rated output current | LO: 3.1 A; HO: 2.2 A |
| Maximum output current | 4.7 A |
| Pulse frequency | 4 kHz |
| Output-frequency limits | Vector control: 0–200 Hz; V/f control: 0–550 Hz |
| Low-overload duty | 150% for 3 s and 110% for 57 s in a 300 s cycle |
| High-overload duty | 200% for 3 s and 150% for 57 s in a 300 s cycle |
| Power factor and efficiency | Power factor 0.85; efficiency 96% |
| Nominal power loss | 40 W |
| Cooling airflow | Internal air cooling; required airflow 0.005 m³/s |
| Operating ambient by duty | LO: −10 to +40 °C; HO: −10 to +50 °C |
| Transport and storage ambient | −25 to +55 °C |
| Installation altitude | 1,000 m |
| Maximum operating humidity | 95% RH, without condensation |
| Power terminals | Plug-in screw terminals for line and motor; 1–2.5 mm² conductors |
| Maximum motor-cable length | 50 m shielded; 100 m unshielded |
| Protection and frame | IP20 / UL open type; FSA |
| Dimensions and net mass | 73 × 196 × 165 mm (W × H × D); 1.4 kg |
Frequently Asked Questions
How much continuous output current should I allow for 6SL3210-1PE13-2UL1 in HO duty?
The HO rated output current is 2.2 A.
Can 6SL3210-1PE13-2UL1 supply twice its HO base current briefly?
The HO overload cycle permits 200% for 3 seconds followed by 150% for 57 seconds in a 300-second cycle.
What overload sequence applies to 6SL3210-1PE13-2UL1 in LO duty?
LO operation permits 150% for 3 seconds and 110% for 57 seconds within a 300-second cycle.
Which pulse frequency is used for the rated data of 6SL3210-1PE13-2UL1?
The specified pulse frequency is 4 kHz.
Can an unshielded motor run of 90 m be used with 6SL3210-1PE13-2UL1?
The stated maximum unshielded motor-cable length is 100 m.
How much mounting space does 6SL3210-1PE13-2UL1 occupy?
The module measures 73 mm wide, 196 mm high and 165 mm deep.
What efficiency should I use for a nominal estimate with 6SL3210-1PE13-2UL1?
The specified efficiency is 96%.