Siemens 6SL3055-0AA00-6AA0 SINAMICS DMC20 DRIVE-CLiQ Hub Module
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Hot Selling Models
- Recommended Products
Overview
- Plan the star topology and connected axis groups before cabling.
- Use only the specified MOTION-CONNECT DRIVE-CLiQ cable types and lengths.
- Include connected participants in the electronics-supply current calculation.
- Maintain 50 mm top and bottom ventilation space and connect the housing ground as specified.
6SL3055-0AA00-6AA0 SINAMICS DMC20 DRIVE-CLiQ Hub Module
A six-socket DRIVE-CLiQ hub for star-shaped axis grouping, with a separate electronics supply and status indication.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SL3055-0AA00-6AA0 |
| Product Type | DRIVE-CLiQ hub module |
| Core Function | Drive communication distribution |
| Application | Cabinet-mounted multi-axis drive systems |
Star-shaped axis grouping
Six DRIVE-CLiQ sockets accommodate the upstream connection and five additional subgroup connections.
Grouped node removal
Individual groups of DRIVE-CLiQ nodes can be removed without interrupting the remaining line.
Supply and communication indication
The READY LED distinguishes active communication, connection establishment and fault states.
Product Overview
6SL3055-0AA00-6AA0 distributes a DRIVE-CLiQ connection to additional axis subgroups.
The hub supports applications in which groups of nodes need to be removed without interrupting data exchange on the remaining DRIVE-CLiQ line.
Key Functions
Star-shaped axis grouping
Six DRIVE-CLiQ sockets accommodate the upstream connection and five additional subgroup connections.
Grouped node removal
Individual groups of DRIVE-CLiQ nodes can be removed without interrupting the remaining line.
Supply and communication indication
The READY LED distinguishes active communication, connection establishment and fault states.
Official Specifications
| Electronics supply | 24 V DC nominal; 20.4–28.8 V range |
|---|---|
| Base current consumption | 0.15 A without DRIVE-CLiQ consumers |
| DRIVE-CLiQ connections | 6 RJ45 sockets, X500–X505; 5 additional subgroup branches |
| Permitted cable lengths | MOTION-CONNECT 500: 100 m maximum; MOTION-CONNECT 800: 50 m maximum |
| Supply connection | X524 screw terminal; maximum conductor section 2.5 mm² |
| Supply loop-through capacity | Maximum 20 A via the connector jumper |
| PE/ground connection | M4 housing stud; 1.8 Nm tightening torque |
| Status indicator | READY LED with green, orange and red states |
| Mechanical mounting | DIN rail with rear latching slide |
| Drawing dimensions | 50 mm width, 150 mm body height, 111 mm depth |
| Weight | 0.8 kg |
Frequently Asked Questions
How many additional DRIVE-CLiQ subgroups can 6SL3055-0AA00-6AA0 connect?
The hub provides five sockets for additional subgroups alongside the upstream connection.
Can 6SL3055-0AA00-6AA0 support removing a group of nodes while other groups continue exchanging data?
The hub is designed for grouped node removal without interrupting the remaining DRIVE-CLiQ line.
Which connection cables should I use with 6SL3055-0AA00-6AA0?
Use MOTION-CONNECT DRIVE-CLiQ cables within the 100 m limit for the 500 series or 50 m limit for the 800 series.
What does a steady green READY LED on 6SL3055-0AA00-6AA0 indicate?
Steady green indicates that the component is ready and cyclic DRIVE-CLiQ communication is taking place.
Why does 6SL3055-0AA00-6AA0 show a steady orange READY LED during startup?
Steady orange indicates that DRIVE-CLiQ communication is being established.
How much ventilation clearance is required around 6SL3055-0AA00-6AA0?
Leave 50 mm clear above and below the component.
Should the supply budget for 6SL3055-0AA00-6AA0 include its connected DRIVE-CLiQ consumers?
The electronics-supply current increases by the consumption of the connected DRIVE-CLiQ participants.