Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6sl3055 0aa00 5ca2 sinamics smc30 cabinet mounted sensor module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6SL3055-0AA00-5CA2 SINAMICS SMC30 Cabinet-Mounted Sensor Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIEMENS SINAMICS

6SL3055-0AA00-5CA2 SINAMICS SMC30 Cabinet-Mounted Sensor Module

A 30 mm SMC30 for TTL, HTL and SSI encoder feedback, with DRIVE-CLiQ communication and a configurable encoder supply.

At a Glance

Brand Siemens
Model 6SL3055-0AA00-5CA2
Product Type Encoder evaluation module
Core Function Transfers measured speed and position to the drive controller
Application SINAMICS encoder-feedback systems

Feedback conversion

Evaluates encoder signals for the Control Unit.

Encoder choices

Supports TTL, HTL and SSI signal types.

Cabinet format

The 30 mm-wide version mounts on a DIN rail.

Product Overview

6SL3055-0AA00-5CA2 evaluates encoder feedback and sends actual position, speed and related sensor information to the SINAMICS Control Unit through DRIVE-CLiQ.

The SMC30 accepts an incremental encoder or an SSI measuring system, including a combined SSI and incremental signal arrangement when both signals represent the same measured variable.

Ordering focus: Match the encoder interface, supply voltage and terminal or D-Sub connection before wiring, and order the DRIVE-CLiQ cable separately.
Key Functions

TTL, HTL and SSI evaluation

The module supports the specified incremental and absolute encoder interfaces for one measuring system.

Selectable encoder supply

The measuring-system supply can provide 5 V DC or the electronics supply minus approximately 1 V, with Remote Sense available at X520 for 5 V encoders.

Drive-system feedback link

DRIVE-CLiQ transfers evaluated feedback to the Control Unit, with cabinet installation and shield connections supporting the complete feedback path.

Official Specifications
Electronics supply 24 V DC nominal; 20.4–28.8 V DC
Current without encoder ≤0.20 A
Current with encoder ≤0.35 A
Encoder supply voltage 5 V DC or electronics supply minus 1 V
Maximum encoder supply current 0.35 A
SSI baud rate 100–250 kHz
Maximum encoder frequency 500 kHz
Maximum TTL encoder cable length 100 m; X520 5 V connection with Remote Sense
Maximum HTL bipolar cable length 300 m
Maximum HTL unipolar cable length 100 m
Maximum SSI cable length 100 m
Maximum power loss 10 W
Degree of protection IP20 / UL open type
Protective-earth connection M4 screw, 1.8 N·m
Dimensions (W × H × D) 30 × 150 × 111 mm
Net weight 0.45 kg
Frequently Asked Questions

Can I connect two separate encoders to 6SL3055-0AA00-5CA2?

Only one measuring system may be connected to one sensor module.

Can 6SL3055-0AA00-5CA2 combine SSI and incremental tracks?

SSI absolute and TTL or HTL incremental signals may be combined at X521/X531 when they are derived from the same measured variable.

How do I avoid damaging a 5 V encoder connected to 6SL3055-0AA00-5CA2?

Select the encoder’s required supply voltage correctly before connecting it, because a 24 V supply can damage 5 V encoder electronics.

Is a DRIVE-CLiQ cable included with 6SL3055-0AA00-5CA2?

The sensor module is supplied without a DRIVE-CLiQ cable.

What clearance should I leave above and below 6SL3055-0AA00-5CA2?

Leave at least 50 mm above and below the module.

How should I terminate the shield when using the terminals on 6SL3055-0AA00-5CA2?

Connect the encoder-cable shield to the module when wiring through the terminals.

Where can I use Remote Sense on 6SL3055-0AA00-5CA2?

Remote Sense is available at X520 for the 5 V measuring-system supply.

Compatibility & Ordering Notes
Before ordering 6SL3055-0AA00-5CA2: Select the SMC30 encoder type and voltage setting for the installed feedback device, include the required cable and provide correct PE and shield connections.

Compatibility Checklist for 6SL3055-0AA00-5CA2

  • Use only one measuring system per module.
  • Match TTL, HTL or SSI signals and the encoder supply voltage.
  • Order the DRIVE-CLiQ cable separately.
  • Provide 50 mm clearance above and below.
  • Connect PE at the M4 housing terminal and terminate terminal-connected cable shields.
Hot Selling Models
Roemheld 1942910
PA-1PK
3237.124
PSU100S 6EP1332-2BA20
BN32-r-1279
LRP-1/8-6 2416371
3108 PS 10 77680341
DBSQ-20/60-W
3SU1801-0AA00-0AA2
Allen-Bradley 1756-IB16ISOE
CAB-GD05 M12
6FX8002-2DC10-1AE0
HGW-32-A
90.23
6GT2891-4EH50

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.