Siemens SIMOVERT MASTERDRIVES CUSA Control Unit 6SE7090-0XX84-0BJ0
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
Siemens • SIMOVERT MASTERDRIVES AFE
6SE7090-0XX84-0BJ0 SIMOVERT MASTERDRIVES CUSA Control Unit
The CUSA Control Unit Sinus AFE board provides the control, terminal and communication interfaces used in compatible SIMOVERT MASTERDRIVES Active Front End equipment.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6SE7090-0XX84-0BJ0 |
| Product Type | Control Unit Sinus AFE board |
| Core Function | Controls the Active Front End and provides command, signal and serial interfaces |
| Application or Compatible Series | SIMOVERT MASTERDRIVES Active Front End systems using a CUSA control board |
Exact Identification
Match 6SE7090-0XX84-0BJ0 character by character and confirm the complete SIMOVERT MASTERDRIVES CUSA Control Unit designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
The CUSA Control Unit Sinus AFE board provides the control, terminal and communication interfaces used in compatible SIMOVERT MASTERDRIVES Active Front End equipment.
The board performs the control and signal-processing functions required by the compatible sinusoidal Active Front End. Coded terminal strips organize external commands, digital signals and analog functions for commissioning and service. An OP1S connection and RS485 or RS232 communication paths support parameterization and system integration.
Key Functions
AFE Control Platform
The board performs the control and signal-processing functions required by the compatible sinusoidal Active Front End.
Accessible Control Terminals
Coded terminal strips organize external commands, digital signals and analog functions for commissioning and service.
Local and Serial Operation
An OP1S connection and RS485 or RS232 communication paths support parameterization and system integration.
Official Specifications
| Board Designation | CUSA; Control Unit Sinus AFE |
|---|---|
| Parameter Board Code | 108 |
| Control Terminal Strips | X100, X101 and X102 |
| X100 Connector | 8-pole coded terminal strip |
| X101 Connector | 8-pole coded terminal strip |
| X102 Connector | 10-pole terminal strip |
| Operator Panel Interface | OP1S connection |
| USS Interface | RS485 |
| Service Serial Interface | RS485 or RS232 at PMU X300 |
| Precharge and External Supply Connector | X9 |
| Supported Conductor Cross-Section | 0.14 to 1.5 mm²; AWG 26 to 16 |
| Recommended Control Conductor | 0.5 mm²; AWG 20 |
| Ferruled Fine-Stranded Conductor | Up to 1 mm² |
| Component Handling | Electrostatic-sensitive device precautions required |
Frequently Asked Questions
Which drive system accepts 6SE7090-0XX84-0BJ0?
Use it only in a compatible SIMOVERT MASTERDRIVES Active Front End that is engineered for the CUSA control board.
What should be saved before removing 6SE7090-0XX84-0BJ0?
Record all AFE parameters, terminal assignments, serial settings, option boards, fault history and commissioning values.
How should the terminal plugs for 6SE7090-0XX84-0BJ0 be handled?
Label every coded plug and conductor before removal so each signal returns to its original terminal position.
Which wire sizes are suitable for 6SE7090-0XX84-0BJ0?
Use conductors within the specified terminal range and apply correctly sized ferrules to fine-stranded wires.
Can an OP1S panel be used with 6SE7090-0XX84-0BJ0?
Yes; connect the compatible panel at its designated interface and restore the validated local operating setup.
How should serial communication be recommissioned on 6SE7090-0XX84-0BJ0?
Reproduce the original physical interface, address, baud rate, protocol and termination settings before enabling the AFE.
What must be tested after installing 6SE7090-0XX84-0BJ0?
Verify terminal states, voltage sensing, precharge control, serial communication, parameter integrity and fault-free AFE operation.
Compatibility & Ordering Notes
Compatibility Checklist
- Use only where the installed SIMOVERT MASTERDRIVES AFE requires the CUSA board.
- Restore the complete parameter set and all coded terminal connections.
- Verify the OP1S, serial interface, voltage-sensing and precharge circuits before enabling power.