Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6se6400 0bp00 0aa1 micromaster 4 basic operator panel bop-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6SE6400-0BP00-0AA1 MICROMASTER 4 Basic Operator Panel BOP

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Great Britain
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
MICROMASTER 4 Accessories

6SE6400-0BP00-0AA1 MICROMASTER 4 Basic Operator Panel BOP

Compact BOP with a five-digit monochrome display for reading drive values, changing parameters and configuring local operation on compatible MICROMASTER drives.

At a Glance

Brand Siemens
Model 6SE6400-0BP00-0AA1
Product Type Basic Operator Panel
Core Function Local parameter editing and drive status display
Application MICROMASTER 4 drive commissioning and operation

Parameter access

The keys and display support viewing and changing drive parameter values.

Operating information

The five-digit, seven-segment display shows parameter values, alarms, faults, setpoints and actual values.

Configured local operation

For MM420 operation from the panel, configure both the command source and the frequency-setpoint source to the BOP.

Product Overview

6SE6400-0BP00-0AA1 is the Basic Operator Panel for the MICROMASTER 4 drive family. Its monochrome display presents parameter numbers and values, alarm and fault information, setpoints and actual values during commissioning and service.

The panel allows parameter editing and local control when the drive command and setpoint sources are configured accordingly. It does not retain a transferable parameter set for copying between drives, so parameter backup must be handled through the drive commissioning workflow.

Ordering focus: Confirm the drive and operator-panel compatibility, then verify command and setpoint sources before changing to local operation.
Key Functions

Parameter access

The keys and display support viewing and changing drive parameter values.

Operating information

The five-digit, seven-segment display shows parameter values, alarms, faults, setpoints and actual values.

Configured local operation

For MM420 operation from the panel, configure both the command source and the frequency-setpoint source to the BOP.

Official Specifications
Display Monochrome LCD, five-digit seven-segment indication
Degree of protection IP20 / UL open type
Dimensions (W × H × D) 71 × 80 × 16 mm
Net weight 0.300 kg
Operating temperature −10 to +50 °C
Storage temperature −40 to +70 °C
Transport temperature −40 to +70 °C
Maximum relative humidity 95% at 25 °C
Listed approvals UL, CE and C-Tick (RCM)
Frequently Asked Questions

Can 6SE6400-0BP00-0AA1 store a parameter set for copying to another drive?

No; the BOP can change parameters but cannot store parameter information for transfer between drives.

Which settings enable local control with 6SE6400-0BP00-0AA1 on an MM420?

Set P0700 to 1 for the BOP command source and P1000 to 1 for the BOP frequency-setpoint source.

Are the motor-control keys of 6SE6400-0BP00-0AA1 active by default on the MM420?

No; panel motor control must first be selected through the appropriate drive parameters.

What happens if 6SE6400-0BP00-0AA1 is removed while an MM420 uses it as its command source?

Removing the BOP stops the MM420 when P0700 is set to 1.

How is 6SE6400-0BP00-0AA1 fitted in place of the standard display panel?

Remove the standard SDP and fit the BOP in its place.

What information can be read from the display of 6SE6400-0BP00-0AA1?

The display presents parameter numbers and values, alarm and fault messages, setpoints and actual values.

Is 6SE6400-0BP00-0AA1 suitable for an exposed installation requiring a higher ingress rating?

The specified protection is IP20 / UL open type, so the enclosure design must provide the protection required by the installation.

Compatibility & Ordering Notes
Before ordering 6SE6400-0BP00-0AA1: Confirm the drive and operator-panel compatibility, then verify command and setpoint sources before changing to local operation.

Before installation

  • Check the exact MICROMASTER drive and panel option before ordering, including whether that drive requires a different operator-panel variant.
  • Document existing command and setpoint-source settings before selecting local BOP control.
  • Use a separate commissioning method when a transferable parameter backup is required.
  • Keep the panel within its ambient limits and provide an enclosure appropriate to its IP20 / UL open-type rating.
Hot Selling Models
P1M-2NK
6XV1871-5BH50
P1M-2NK P1M-2NK/24V~/1A1R 479219
3RV2011-1JA20 3RV2901-2A
SW80B7
ER-31
CLH31A/BW
LRB-D-7-O-MIDI
3RV2011-1CA25
3RV2011-1JA15
3RV2021-4PA15
IT5001 ITB3001-BP0G
LGH 28.8D1
ESX10-TB-101-DC24V-2A-E
EL6002

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.