Siemens · SIMATIC RF600

6GT2811-6BC10-2AA0 RF610R CMIIT UHF RFID Reader

Siemens 6GT2811-6BC10-2AA0 is the SIMATIC RF610R CMIIT UHF RFID reader with an integrated antenna, industrial Ethernet and PROFINET connectivity, IP67 protection and a one-metre maximum reading range.

At a Glance

Brand Siemens
Model 6GT2811-6BC10-2AA0
Product Type Industrial UHF RFID reader with integrated antenna
Core Function Reads and writes passive UHF tags over industrial Ethernet
Application or Compatible Series SIMATIC Ident RF600 systems approved for the CMIIT band

Regional Variant

Use the CMIIT variant only where its 920.625 to 924.375 MHz radio approval applies.

Read-Zone Setup

Set the transmit power and mounting position to cover the required tag path without unwanted reads.

Network Commissioning

Assign the Ethernet or PROFINET identity and verify the controller or host communication path.

Product Overview

Siemens 6GT2811-6BC10-2AA0 is the SIMATIC RF610R CMIIT UHF RFID reader with an integrated antenna, industrial Ethernet and PROFINET connectivity, IP67 protection and a one-metre maximum reading range.

The internal antenna creates a compact read point without a separate RF cable or antenna. Ethernet, PROFINET, TCP/IP and OPC UA options integrate identification data with automation systems. A browser interface supports configuration and diagnostic work from a connected service computer.

Ordering focus: confirm the CMIIT radio region, tag protocol, required read range, mounting orientation, sealed connections, 24 V supply and Ethernet or PROFINET configuration.
Key Functions

Integrated UHF Antenna

The internal antenna creates a compact read point without a separate RF cable or antenna.

Industrial Network Access

Ethernet, PROFINET, TCP/IP and OPC UA options integrate identification data with automation systems.

Web-Based Service

A browser interface supports configuration and diagnostic work from a connected service computer.

Official Specifications
CMIIT Operating Frequency 920.625 to 924.375 MHz
Adjustable Transmit Power 3 to 400 mW
Maximum CMIIT Radiated Power 250 mW ERP
Maximum Range with Internal Antenna 1 m
Air-Interface Protocol ISO 18000-62 and ISO 18000-63
Maximum Transmission Speed 300 kbit/s
Frequency Accuracy ±10 ppm maximum
CMIIT Channel Spacing 250 kHz
Modulation and Encoding DSB-ASK or PR-ASK with Manchester or PIE
Typical Write Time per Byte 2 ms
Typical Read Time per Byte 0.15 ms
Supply Voltage 24 V DC, 20 to 30 V DC permitted
Maximum Current Consumption 0.3 A
Dimensions 140.5 x 133 x 45 mm
Weight 370 g
Mounting Pattern VESA 100 with four M4 screws
Tightening Torque for Mounting Screws 1.5 N·m
Status Indication 6 LEDs
Degree of Protection IP67
Antenna Polarization Circular
Frequently Asked Questions

Where can I legally operate 6GT2811-6BC10-2AA0?

Use the reader only in locations covered by the CMIIT radio approval and its assigned UHF band.

How far can 6GT2811-6BC10-2AA0 read a compatible tag?

The internal antenna provides a maximum specified range of one metre under suitable installation conditions.

How should I reduce unwanted reads around 6GT2811-6BC10-2AA0?

Lower the transmit power and adjust reader position, tag orientation and shielding around the intended read zone.

Which tag air interface works with 6GT2811-6BC10-2AA0?

Use passive UHF transponders that support ISO 18000-62 or ISO 18000-63.

Can 6GT2811-6BC10-2AA0 be mounted in a washdown-area enclosure?

The reader itself is rated IP67 when installed with correctly sealed connections and accessories.

What network settings must be restored after replacing 6GT2811-6BC10-2AA0?

Restore the device name, IP configuration, controller assignment and application communication parameters.

How should I mechanically mount 6GT2811-6BC10-2AA0?

Use the VESA 100 pattern with four M4 screws tightened to the specified torque.

Compatibility & Ordering Notes
Before ordering 6GT2811-6BC10-2AA0: confirm the CMIIT radio region, tag protocol, required read range, mounting orientation, sealed connections, 24 V supply and Ethernet or PROFINET configuration.

Compatibility Checklist

  • Use only the CMIIT radio variant in the authorized 920.625 to 924.375 MHz region.
  • Confirm the selected tags support the reader air-interface protocols and fit the required read-zone geometry.
  • Preserve the Ethernet or PROFINET identity, application commands, transmit power and mounting orientation.
Hot Selling Models
R161952130
SH10 833-84
ABB TH101
5SX22 C4 5SX2
3RT2016-1BB42 3RH2911-1AA01 3RT2916-1BB00
A9A15306
FC3C
SMIOINTF/1
200B-8DI/8DO 6ES7133-0BH01-0XB0 193-0CA30-0XA0
6NH9810-2A
3RV1011-1KA15
HAS01.1-075-072-MN R911306619
1023500000
6ES5530-3LA12
7000-12041-0350750

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.