Overview
- Use a compatible MOBY I ASM with a 19,200-baud RS 422 SLG interface.
- Select the MDS first because the working field depends on the data-memory type.
- Keep the ASM-to-SLG cable within 85 m at 24 V DC.
- Maintain more than 2,000 mm between adjacent SLG 43 devices.
- Use more than 20 mm metal clearance where the full field range is required.
Siemens · MOBY I
6GT2001-0CA10 SLG 43 Industrial Read/Write Device
Siemens 6GT2001-0CA10 is the MOBY I SLG 43 high-power inductive read/write device for communicating with compatible mobile data memories over a large industrial transmission window.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6GT2001-0CA10 |
| Product Type | MOBY I SLG 43 Inductive Read/Write Device |
| Core Function | Reads and writes mobile data-memory information across a large transmission window |
| Application or Compatible Series | MOBY I identification systems and compatible MDS data carriers |
High-Power Field Range
Plan a 0 to 100 mm operating distance and a 150 mm limit distance according to the selected MDS.
ASM Serial Connection
Use the 6-pin DIN 43651 connector with a 19,200-baud RS 422 link.
Installation Clearance
Maintain separation from adjacent readers and metal surfaces to preserve the transmission field.
Product Overview
Siemens 6GT2001-0CA10 is the MOBY I SLG 43 high-power inductive read/write device for communicating with compatible mobile data memories over a large industrial transmission window.
Reads and writes tag data at 19,200 baud through an inductive transmission field. The extended transmission window accommodates conveyor tolerances and dynamic data transfer. The polyamide housing provides IP65 protection across a −25 to +70 °C operating range.
Key Functions
Inductive MDS Communication
Reads and writes tag data at 19,200 baud through an inductive transmission field.
Large Dynamic Window
The extended transmission window accommodates conveyor tolerances and dynamic data transfer.
Industrial Enclosure
The polyamide housing provides IP65 protection across a −25 to +70 °C operating range.
Official Specifications
| MDS Data Transmission Rate | 19,200 baud |
|---|---|
| Operating Distance | 0 to 100 mm, dependent on the MDS |
| Limit Distance | 150 mm |
| Power Transmission Frequency | 134 kHz |
| Data Transmission Frequency | 1.81 MHz |
| ASM Serial Interface | RS 422 at 19,200 baud |
| SLG Connector | 6-pin connector according to DIN 43651 |
| Maximum ASM-to-SLG Cable Length | 85 m at 24 V DC |
| Supply Voltage | 24 V DC nominal; permissible range 21 to 30 V DC |
| Current Consumption | 60 mA idle; 250 mA during operation |
| MTBF | 2 × 10⁶ hours |
| Housing | Gray polyamide 12; 238 × 40 × 80 mm |
| Protection Rating | IP65 |
| Mechanical Resistance | Shock 50 g; vibration 20 g |
| Mounting | Four M5 screws; 2 Nm tightening torque at room temperature |
| Operating Temperature | −25 to +70 °C |
| Transport and Storage Temperature | −40 to +85 °C |
| Approximate Weight | 800 g |
| Minimum Reader-to-Reader Distance | Greater than 2,000 mm |
| Metal-Mounting Clearance | More than 20 mm recommended; direct metal mounting can reduce range by up to 30% |
Frequently Asked Questions
Which MOBY I data carriers are particularly suitable for 6GT2001-0CA10?
The large transmission window is especially suited to large mobile data memories such as MDS 506 and MDS 439 E.
What working range can I plan for 6GT2001-0CA10?
The operating distance is 0 to 100 mm and the limit distance is 150 mm, with the exact field determined by the selected MDS.
How far can I run the interface cable from 6GT2001-0CA10 to an ASM?
The RS 422 connection permits a maximum cable length of 85 m when supplied at 24 V DC.
Can 6GT2001-0CA10 be mounted directly on metal?
Direct metal mounting is possible, but range can fall by up to 30%, so a gap greater than 20 mm is recommended.
What power source should I provide for 6GT2001-0CA10?
Use a 24 V DC supply within 21 to 30 V DC that can provide up to 250 mA during operation.
How much separation is needed between adjacent 6GT2001-0CA10 readers?
Keep adjacent readers more than 2,000 mm apart to avoid mutual field interference.
Is 6GT2001-0CA10 suitable for exposed industrial areas?
Its IP65 housing and −25 to +70 °C operating range support demanding industrial installations within the stated limits.