Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6gt2001 0ca10 moby i slg43 read write device-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens MOBY I 6GT2001-0CA10 SLG 43 Industrial Read/Write Device

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · MOBY I

6GT2001-0CA10 SLG 43 Industrial Read/Write Device

Siemens 6GT2001-0CA10 is the MOBY I SLG 43 high-power inductive read/write device for communicating with compatible mobile data memories over a large industrial transmission window.

At a Glance

Brand Siemens
Model 6GT2001-0CA10
Product Type MOBY I SLG 43 Inductive Read/Write Device
Core Function Reads and writes mobile data-memory information across a large transmission window
Application or Compatible Series MOBY I identification systems and compatible MDS data carriers

High-Power Field Range

Plan a 0 to 100 mm operating distance and a 150 mm limit distance according to the selected MDS.

ASM Serial Connection

Use the 6-pin DIN 43651 connector with a 19,200-baud RS 422 link.

Installation Clearance

Maintain separation from adjacent readers and metal surfaces to preserve the transmission field.

Product Overview

Siemens 6GT2001-0CA10 is the MOBY I SLG 43 high-power inductive read/write device for communicating with compatible mobile data memories over a large industrial transmission window.

Reads and writes tag data at 19,200 baud through an inductive transmission field. The extended transmission window accommodates conveyor tolerances and dynamic data transfer. The polyamide housing provides IP65 protection across a −25 to +70 °C operating range.

Ordering focus: confirm the MOBY I ASM, selected MDS, operating distance, RS 422 interface, cable length, 24 V DC supply, reader spacing, metal clearance, sealing and temperature range.

Key Functions

Inductive MDS Communication

Reads and writes tag data at 19,200 baud through an inductive transmission field.

Large Dynamic Window

The extended transmission window accommodates conveyor tolerances and dynamic data transfer.

Industrial Enclosure

The polyamide housing provides IP65 protection across a −25 to +70 °C operating range.

Official Specifications

MDS Data Transmission Rate 19,200 baud
Operating Distance 0 to 100 mm, dependent on the MDS
Limit Distance 150 mm
Power Transmission Frequency 134 kHz
Data Transmission Frequency 1.81 MHz
ASM Serial Interface RS 422 at 19,200 baud
SLG Connector 6-pin connector according to DIN 43651
Maximum ASM-to-SLG Cable Length 85 m at 24 V DC
Supply Voltage 24 V DC nominal; permissible range 21 to 30 V DC
Current Consumption 60 mA idle; 250 mA during operation
MTBF 2 × 10⁶ hours
Housing Gray polyamide 12; 238 × 40 × 80 mm
Protection Rating IP65
Mechanical Resistance Shock 50 g; vibration 20 g
Mounting Four M5 screws; 2 Nm tightening torque at room temperature
Operating Temperature −25 to +70 °C
Transport and Storage Temperature −40 to +85 °C
Approximate Weight 800 g
Minimum Reader-to-Reader Distance Greater than 2,000 mm
Metal-Mounting Clearance More than 20 mm recommended; direct metal mounting can reduce range by up to 30%

Frequently Asked Questions

Which MOBY I data carriers are particularly suitable for 6GT2001-0CA10?

The large transmission window is especially suited to large mobile data memories such as MDS 506 and MDS 439 E.

What working range can I plan for 6GT2001-0CA10?

The operating distance is 0 to 100 mm and the limit distance is 150 mm, with the exact field determined by the selected MDS.

How far can I run the interface cable from 6GT2001-0CA10 to an ASM?

The RS 422 connection permits a maximum cable length of 85 m when supplied at 24 V DC.

Can 6GT2001-0CA10 be mounted directly on metal?

Direct metal mounting is possible, but range can fall by up to 30%, so a gap greater than 20 mm is recommended.

What power source should I provide for 6GT2001-0CA10?

Use a 24 V DC supply within 21 to 30 V DC that can provide up to 250 mA during operation.

How much separation is needed between adjacent 6GT2001-0CA10 readers?

Keep adjacent readers more than 2,000 mm apart to avoid mutual field interference.

Is 6GT2001-0CA10 suitable for exposed industrial areas?

Its IP65 housing and −25 to +70 °C operating range support demanding industrial installations within the stated limits.

Compatibility & Ordering Notes

Before ordering 6GT2001-0CA10: confirm the MOBY I ASM, selected MDS, operating distance, RS 422 interface, cable length, 24 V DC supply, reader spacing, metal clearance, sealing and temperature range.

Compatibility Checklist

  • Use a compatible MOBY I ASM with a 19,200-baud RS 422 SLG interface.
  • Select the MDS first because the working field depends on the data-memory type.
  • Keep the ASM-to-SLG cable within 85 m at 24 V DC.
  • Maintain more than 2,000 mm between adjacent SLG 43 devices.
  • Use more than 20 mm metal clearance where the full field range is required.
Hot Selling Models
P33AB-9200
CA4KN 22BW3 042859
M000GL20K N5012413
PQ96 16055
3RT2015-1BB42 3RT2916-1BB00
3RH1921-1EA11
QSLV6-1/2-12153250
ZSLM001
LR2D1314
OST-7-2THKOA
4003K 18814886
3TH20 40-0AH0
M22LY 216774
NH00GG50V125
6ES7131-0BH00-0XB0

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.