Siemens SIMATIC NET CP 442-1 RNA Communication Processor 6GK7442-1RX00-0XE0

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC S7-400 / CP 442-1 RNA

6GK7442-1RX00-0XE0 SIMATIC NET CP 442-1 RNA Communication Processor

The CP 442-1 RNA equips an S7-400 station with PRP-capable redundant Ethernet connections plus S7 communication, open communication and network diagnostics.

At a Glance

Brand Siemens
Model 6GK7442-1RX00-0XE0
Product Type Industrial Ethernet communication processor
Core Function Adds redundant PRP Ethernet and S7/open communication services to a SIMATIC S7-400 station
Application or Compatible Series S7-400 systems requiring Parallel Redundancy Protocol connectivity and Industrial Ethernet services

Exact Identification

Match 6GK7442-1RX00-0XE0 character by character and confirm the complete SIMATIC NET CP 442-1 RNA Communication Processor designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The CP 442-1 RNA equips an S7-400 station with PRP-capable redundant Ethernet connections plus S7 communication, open communication and network diagnostics.

Two PRP interfaces connect the controller to redundant LAN A and LAN B networks. The processor supports S7 communication, ISO, ISO-on-TCP, TCP and UDP services. Web diagnostics, SNMP and clock synchronization assist plant operation and service.

Ordering focus: confirm the complete CP 442-1 RNA article number, S7-400 rack compatibility, firmware, PRP LAN assignments, IP configuration and saved communication connections.
Key Functions

Parallel Redundancy

Two PRP interfaces connect the controller to redundant LAN A and LAN B networks.

Multiple Communication Services

The processor supports S7 communication, ISO, ISO-on-TCP, TCP and UDP services.

Integrated Diagnostics

Web diagnostics, SNMP and clock synchronization assist plant operation and service.

Official Specifications
Processor Type CP 442-1 RNA
Host System SIMATIC S7-400
PRP Interfaces 2
PRP Port Speed 100 Mbit/s
PRP Connection RJ45
Additional Ethernet Interface 1 × RJ45
Additional Interface Rate 10/100 Mbit/s
Redundancy Protocol Parallel Redundancy Protocol
S7 Communication S7 communication on the standard Ethernet and RNA/PRP interfaces; H communication on the RNA/PRP interface
Open Communication TCP, UDP and ISO-on-TCP
ISO Transport ISO transport on both interfaces; ISO-on-TCP, TCP and UDP on the RNA/PRP interface
S7 Routing S7 routing through the standard Ethernet and RNA/PRP interfaces
Web Diagnostics HTTP-based Web diagnostics for module and communication status
Network Management SNMPv1
Clock Synchronization SIMATIC procedure and NTP on the RNA/PRP interface
Net Weight 0.847 kg
Frequently Asked Questions

Which redundancy method is provided by 6GK7442-1RX00-0XE0?

It connects to two independent Ethernet LANs using Parallel Redundancy Protocol.

Can both PRP ports of 6GK7442-1RX00-0XE0 be placed in one ordinary LAN?

No; connect the designated interfaces to the separate PRP networks defined by the system design.

Which controller family hosts 6GK7442-1RX00-0XE0?

Install it in a supported SIMATIC S7-400 rack and hardware configuration.

Which open protocols are available on 6GK7442-1RX00-0XE0?

The communication services include TCP, UDP and ISO-on-TCP.

How can 6GK7442-1RX00-0XE0 be diagnosed during operation?

Use the status LEDs, STEP 7 diagnostics, web diagnostics and supported SNMP functions.

What should be saved before replacing 6GK7442-1RX00-0XE0?

Preserve the STEP 7 hardware configuration, IP settings, PRP assignments and communication connections.

What must be checked after installing 6GK7442-1RX00-0XE0?

Verify LAN A and LAN B separation, connection status, redundancy behavior and all configured S7 and open connections.

Compatibility & Ordering Notes
Before ordering 6GK7442-1RX00-0XE0: confirm the complete CP 442-1 RNA article number, S7-400 rack compatibility, firmware, PRP LAN assignments, IP configuration and saved communication connections.

Compatibility Checklist

  • Maintain separate PRP LAN A and LAN B connections.
  • Use the supported S7-400 hardware configuration and firmware combination.
  • Restore all communication connections and verify redundant traffic paths.
Hot Selling Models
Allen-Bradley 100F
HG 6A 315.3 400/5A
S401MD13S401M-D13 2CCS571001R0131
3RG4621-7AG02
BMF303K-PS-C-2-S49-00.2
BES516-3005-E5-C-S49
ST16
GV2-RT10
IE5203 IEA2001-FROG/US
9/10-24/350
CPA10-EB1-HR
CMEM03T
LE4-116-DD1
CPV10RZP
X20 TB12

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.