siemens 6gk5602 0ba10 2aa3 scalance s602 security module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SCALANCE S602 6GK5602-0BA10-2AA3 Industrial Security Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS SCALANCE S SECURITY

Siemens SCALANCE S602 6GK5602-0BA10-2AA3 Industrial Security Module

6GK5602-0BA10-2AA3 is a SCALANCE S602 security module with separate internal and external Ethernet ports, configurable firewall rules and redundant 24 V DC supply.

At a Glance

Brand Siemens
Model 6GK5602-0BA10-2AA3
Product Type Industrial Security Module
Core Function Firewall protection for automation networks
Application Segmentation of protected industrial network cells

Network Separation

One RJ45 port for the internal network and one for the external network.

Security Configuration

Up to 256 firewall rules with configuration through Siemens security engineering tools.

Industrial Installation

Wide-temperature operation with DIN rail, S7-300 rail or wall mounting.

Product Overview

Siemens 6GK5602-0BA10-2AA3 is the SCALANCE S602 module for protecting devices, networks and industrial communication with firewall-controlled separation between internal and external network segments.

The unit provides two copper Ethernet interfaces, removable C-PLUG support, a signaling contact and redundant 24 V DC terminals in a compact industrial enclosure.

Ordering focus: confirm the network segmentation concept, firewall rule set, engineering tool version, power architecture, temperature range and mechanical mounting.

Key Functions

Internal and External Network Separation

Dedicated RJ45 ports create a controlled boundary between the protected automation cell and the external network.

Configurable Firewall Policy

The security configuration supports up to 256 firewall rules for traffic control at the industrial cell boundary.

Serviceable Project Configuration

A removable C-PLUG can retain configuration data, while Siemens Security Configuration Tool or STEP 7 supports engineering and commissioning.

Official Specifications

Ethernet Network Interfaces 1 internal RJ45 port and 1 external RJ45 port
Ethernet Transmission Rates 10, 100 and 1000 Mbit/s
Signaling Contact 1 × 2-pole terminal block, 24 V DC, maximum 0.1 A
Power Supply Connector 1 × 4-pole terminal block with redundant feed
Rated Supply Voltage 24 V DC
Permissible Supply Range 19.2–28.8 V DC
Maximum Current Consumption 0.5 A
Typical Active Power Loss 6.72 W at 24 V DC
Supply Input Fuse Non-replaceable F 3 A / 32 V melting fuse
Removable Storage C-PLUG supported
Maximum Firewall Rules 256
Operating Temperature -40 °C to +60 °C in normal horizontal installation
Alternative Installation Temperature -40 °C to +40 °C for other mounting positions
Storage and Transport Temperature -40 °C to +80 °C
Relative Humidity Maximum 95% at 25 °C, non-condensing
Protection Rating IP20
Installation Options 35 mm DIN rail, S7-300 standard rail or wall mounting
Dimensions 60 × 125 × 124 mm
Weight 790 g
Mean Time Between Failures 54.56 years at 40 °C

Frequently Asked Questions

Where should I place 6GK5602-0BA10-2AA3 in the network?

Install the module between the protected internal automation network and the external network using the dedicated RJ45 interfaces.

How many firewall rules can I configure in 6GK5602-0BA10-2AA3?

The security configuration supports up to 256 firewall rules.

Which DC supply should I provide for 6GK5602-0BA10-2AA3?

Provide 24 V DC within the permitted range of 19.2 to 28.8 V DC.

What should I check for the signaling contact on 6GK5602-0BA10-2AA3?

Wire the two-pole contact for 24 V DC and keep its load at or below 0.1 A.

Which engineering tools can configure 6GK5602-0BA10-2AA3?

Use Siemens Security Configuration Tool or STEP 7 V12 or higher for supported security engineering.

How can I mount 6GK5602-0BA10-2AA3 in a control cabinet?

Use a 35 mm DIN rail, an S7-300 standard rail, or the documented wall-mounting arrangement.

What temperature range applies to 6GK5602-0BA10-2AA3?

Normal horizontal installation permits -40 °C to +60 °C, while other positions are limited to -40 °C to +40 °C.

Compatibility & Ordering Notes

Before ordering 6GK5602-0BA10-2AA3: review the installed network zones, project firewall policy, power wiring, C-PLUG handling, engineering software and cabinet mounting before replacement.

Compatibility Checklist

  • Map the internal and external ports to the intended network zones.
  • Export or secure the existing firewall configuration before replacement.
  • Confirm compatible Siemens engineering software and project access.
  • Observe the position-dependent temperature limits and cabinet clearances.
Hot Selling Models
Allen-Bradley 1492-SP1C070
DILM7-10 XTCE007B10
3SE5 112-0CH50
3TH8293-0A
3A1R
DSN-16-60-PPV
PTM50.16V01
H12WD4890PG
MS6-DL-1/2
6EP1331-1SL11
1200661035
1527690000
3RT1025-3BB40 3RH1921-2HA31
KMF-1-24-10-LED
1771-OBD/C