Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6fx2001 2ef00 ttl rs422 5000 pulse incremental encoder-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6FX2001-2EF00 TTL RS422 5000-Pulse Incremental Encoder

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
Incremental encoder measurement components

6FX2001-2EF00 TTL RS422 5000-Pulse Incremental Encoder

A five-volt incremental encoder with complementary TTL signaling, a 6 mm shaft and distinct electrical and mechanical speed limits.

At a Glance

Brand Siemens
Model 6FX2001-2EF00
Product Type Rotary incremental feedback encoder
Core Function Supplying angular-position pulse feedback
Application Compatible incremental-signal evaluation electronics

Incremental pulse generation

The encoder supplies 5000 pulses per revolution with quadrature A and B signals.

Differential line signaling

TTL RS422 signaling connects the encoder to compatible downstream electronics.

Defined shaft and environmental limits

Separate housing and shaft-entry protection ratings accompany the mechanical shaft-load limits.

Product Overview

6FX2001-2EF00 generates incremental position feedback for the connected evaluation electronics.

The output uses TTL RS422 signal levels and a 90-degree relationship between the A and B tracks, with the maximum pulse frequency determining the electrical speed limit.

Ordering focus: Match the 5 V supply, TTL RS422 receiver, 5000-pulse resolution, shaft loading and electrical speed limit.
Key Functions

Incremental pulse generation

The encoder supplies 5000 pulses per revolution with quadrature A and B signals.

Differential line signaling

TTL RS422 signaling connects the encoder to compatible downstream electronics.

Defined shaft and environmental limits

Separate housing and shaft-entry protection ratings accompany the mechanical shaft-load limits.

Official Specifications
Operating voltage 5 V DC ±10%
Maximum unloaded current 150 mA
Signal levels TTL RS422
Resolution 5,000 pulses per revolution
Maximum sampling frequency 300 kHz
Signal transition time Maximum 50 ns for the 10–90% transition
A-to-B phase relation 90°
Edge clearance at 300 kHz 0.45 µs
LED failure response High-impedance driver
Maximum downstream cable 100 m
Shaft dimensions 6 mm diameter; 10 mm length
Maximum angular acceleration 100,000 rad/s²
Rotor inertia 0.00000145 kg·m²
Friction and starting torque 0.01 N·m at 20 °C
Maximum speeds 3,600 rpm electrical; 12,000 rpm mechanical
Shaft loading up to 6,000 rpm 40 N axial; 60 N radial at shaft end
Shaft loading above 6,000 rpm 10 N axial; 20 N radial at shaft end
Vibration limit 300 m/s² at 55–2,000 Hz
Shock limits 2,000 m/s² for 2 ms; 1,000 m/s² for 6 ms
Protection and mass IP67 housing, IP64 shaft entry; 0.3 kg
Frequently Asked Questions

Can I power 6FX2001-2EF00 from a 24 V sensor supply?

The encoder requires 5 V DC with a tolerance of ±10%.

Can I use the 12,000 rpm mechanical figure as the full electrical operating speed of 6FX2001-2EF00?

The stated electrical speed limit is 3,600 rpm, while 12,000 rpm is the mechanical limit.

Which signal receiver should I use with 6FX2001-2EF00?

Use evaluation electronics compatible with TTL RS422 signal levels.

Does the shaft entry of 6FX2001-2EF00 have the same protection as its housing?

The housing is rated IP67 and the shaft entry is rated IP64.

How long may the cable from 6FX2001-2EF00 to the evaluation electronics be?

The specified maximum cable length is 100 m.

What changes in the shaft-load limit of 6FX2001-2EF00 above 6,000 rpm?

The permitted load reduces to 10 N axial and 20 N radial at the shaft end.

What phase relationship should the A and B signals of 6FX2001-2EF00 have?

The A and B tracks have a 90-degree phase relationship.

Compatibility & Ordering Notes
Before ordering 6FX2001-2EF00: Match the 5 V supply, TTL RS422 receiver, 5000-pulse resolution, shaft loading and electrical speed limit.

Before installation

  • Provide the specified 5 V supply and a compatible TTL RS422 receiver.
  • Choose the mechanical coupling for the 6 mm shaft and the permitted shaft forces.
  • Respect the electrical speed and pulse-frequency limit separately from the mechanical speed rating.
  • Apply the correct housing and shaft-entry protection requirements and downstream cable limit.
Hot Selling Models
LC1D25B7
E82ZWBRB
3LD2504-0TK53
6ES5 380-7AA11
MNF532...-R
EC 2092
FB-TA-M12
81151,510 BK06/8E/8A/RS232
EVT317-5D0-02F-Q
3826.024.00
XTCF032C01
DCUJB10-10DM CUJ0C31
3RT1966-4G
3TA1DG30
R-12-08-R

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.