Overview
Siemens · SIMATIC DP
6ES7972-0AA02-0XA0 RS485 PROFIBUS/MPI Repeater
Siemens 6ES7972-0AA02-0XA0 is a SIMATIC DP RS485 repeater for coupling PROFIBUS or MPI bus segments at rates up to 12 Mbit/s and supporting up to 31 nodes per segment.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7972-0AA02-0XA0 |
| Product Type | RS485 bus repeater |
| Core Function | Regenerates and isolates PROFIBUS or MPI bus segments |
| Application or Compatible Series | SIMATIC PROFIBUS DP and MPI networks |
Segment Design
Use the repeater to divide the network into correctly terminated RS485 segments within node and cable limits.
Power Loading
Include any PG/OP socket load when sizing the 24 V supply.
Commissioning Check
Match the baud rate, shield continuity, terminal assignment and segment termination before energizing the network.
Product Overview
Siemens 6ES7972-0AA02-0XA0 is a SIMATIC DP RS485 repeater for coupling PROFIBUS or MPI bus segments at rates up to 12 Mbit/s and supporting up to 31 nodes per segment.
The repeater restores bus levels between two PROFIBUS or MPI segments. Electrical separation limits disturbance propagation between connected bus sections. Automatic operation covers standard PROFIBUS rates from 9.6 kbit/s to 12 Mbit/s.
Key Functions
RS485 Signal Regeneration
The repeater restores bus levels between two PROFIBUS or MPI segments.
Segment Isolation
Electrical separation limits disturbance propagation between connected bus sections.
Broad Bus-Speed Range
Automatic operation covers standard PROFIBUS rates from 9.6 kbit/s to 12 Mbit/s.
Official Specifications
| Rated Supply Voltage | 24 V DC |
|---|---|
| Permitted Supply Range | 20.4 to 28.8 V DC |
| Maximum Current without PG/OP Load | 100 mA |
| Maximum Current with 5 V PG/OP Load | 130 mA at a 5 V, 90 mA socket load |
| Maximum Current with 24 V PG/OP Load | 200 mA at a 24 V, 100 mA socket load |
| Typical Power Loss | 0.7 W |
| PROFIBUS Transfer Range | 9.6 kbit/s to 12 Mbit/s |
| Maximum Nodes per Segment | 31 |
| Supply Connection | Terminal module |
| PROFIBUS Cable Connections | 2 terminal blocks |
| Degree of Protection | IP20 |
| Operating Temperature | 0 to 60 °C |
| Storage and Transport Temperature | -40 to 70 °C |
| Maximum Operating Humidity | 95 percent at 25 °C |
| Dimensions | 45 x 128 x 59.3 mm |
| Approximate Weight | 350 g |
Frequently Asked Questions
When should I add 6ES7972-0AA02-0XA0 to a PROFIBUS network?
Use the repeater when a network must be divided into additional RS485 segments or its signal levels must be regenerated.
How many stations can share one segment with 6ES7972-0AA02-0XA0?
Each connected segment can contain up to thirty-one nodes within the applicable bus rules.
Does 6ES7972-0AA02-0XA0 work on an MPI network?
Yes, the repeater is designed for both PROFIBUS and MPI RS485 bus systems.
What supply range is acceptable for 6ES7972-0AA02-0XA0?
Provide a regulated DC supply between 20.4 and 28.8 volts.
Why must PG/OP loading be included for 6ES7972-0AA02-0XA0?
Equipment powered through the service socket increases the repeater supply-current requirement.
How should the two bus sections around 6ES7972-0AA02-0XA0 be terminated?
Treat each side as a separate RS485 segment and apply termination at the physical ends of both sections.
Which wiring details should be recorded before changing 6ES7972-0AA02-0XA0?
Record both cable pairs, shield connections, segment ends, node counts, baud rate and supply terminals.
Compatibility & Ordering Notes
Compatibility Checklist
- Confirm that both connected networks use PROFIBUS or MPI RS485 electrical signaling.
- Count the nodes and check cable length independently on each repeater segment.
- Size the power supply for the highest current case when the PG or OP socket is loaded.