Overview

SIMATIC ET 200PA SMART • DIGITAL OUTPUT

6ES7650-8EK80-0AA0 ET 200PA SMART DO32 Digital Output Module

Standard 32-channel 24 V DC output module with 0.5 A rated output current per channel.

At a Glance

Brand Siemens
Model 6ES7650-8EK80-0AA0
Product Type DO32 digital output module
Core Function 32 DC output channels
Compatible Series ET 200PA SMART

Exact Identification

Standard DO32 article; the coated module uses a different order suffix.

Output Connection

Four groups of eight outputs use a 40-pin front connector.

Engineering Check

Check load voltage, actuator current and group current before installation.

Product Overview

6ES7650-8EK80-0AA0 is the standard DO32 digital output module for ET 200PA SMART. It provides 32 outputs isolated in groups of eight, with a rated 24 V DC load voltage and 0.5 A output current per channel.

The module is suitable for solenoid valves, DC contactors and signal lamps. A green status LED is provided per channel and an SF LED indicates a group error.

Ordering focus: Match the standard article suffix, 40-pin front connector and existing four-group load wiring before replacement.
Key Functions

Grouped digital outputs

The 32 outputs are electrically isolated in four groups of eight for 24 V DC actuator circuits.

Actuator switching

The module switches resistive loads at up to 100 Hz and lamp loads at up to 10 Hz.

Local status indication

Each channel has a green status LED, with a separate SF group error display.

Official Specifications
Module dimensions 40 × 125 × 120 mm
Approximate module weight 300 g
Maximum unshielded cable length 600 m
Maximum shielded cable length 1000 m
Group current, horizontal mounting to 40 °C 4 A maximum
Group current, horizontal mounting to 60 °C 3 A maximum
Group current, vertical mounting to 40 °C 2 A maximum
Backplane bus current consumption 60 mA maximum
No-load L+ current consumption 100 mA maximum
Typical power loss 9.3 W
Permitted output current at signal 1 5 mA to 0.6 A
Residual output current at signal 0 0.5 mA maximum
Output delay, signal 0 to 1 200 µs maximum with resistive load
Output delay, signal 1 to 0 300 µs maximum with resistive load
Load resistance range 48 Ω to 4 kΩ
Maximum lamp load 5 W
Resistive-load switching frequency 100 Hz maximum
Inductive-load switching frequency 0.5 Hz maximum, IEC 947-5-1 DC 13
Electronic short-circuit response threshold 1 A typical
Actuator connection 40-pin front connector
Frequently Asked Questions

Can 6ES7650-8EK80-0AA0 switch a 24 V DC solenoid valve?

Yes, the output module is suitable for solenoid valves when each channel and group stays within its rated current.

How many load groups should I wire for 6ES7650-8EK80-0AA0?

Wire the 32 output channels as four electrically isolated groups of eight.

Which front connector is needed for 6ES7650-8EK80-0AA0?

The actuator wiring uses a 40-pin front connector.

Can I use 6ES7650-8EK80-0AA0 for a redundant load?

Two outputs can control one load redundantly, while their parallel connection cannot be used to increase output capacity.

What do the LEDs on 6ES7650-8EK80-0AA0 indicate?

A green LED displays each channel status and the SF LED displays a group error.

How long can the shielded field cable be with 6ES7650-8EK80-0AA0?

The maximum stated shielded cable length is 1000 m.

Does 6ES7650-8EK80-0AA0 provide configurable diagnostic interrupts?

No, this DO32 module has neither configurable diagnostics nor diagnostic interrupts.

Compatibility & Ordering Notes
Before ordering 6ES7650-8EK80-0AA0: Use the standard -0AA0 module for the specified installation; the conformal-coated version carries suffix -1AA0.

Installation checklist

  • Match the full article number and the ET 200PA SMART station configuration.
  • Confirm 24 V DC load supply and group current against the mounting orientation and ambient temperature.
  • Use the 40-pin front connector and preserve the existing four-group channel mapping.
  • Do not substitute the DO16 module when the project requires 32 outputs.
Hot Selling Models
2011223
MK9906 0044859
3842535428
1MK-10 230/240V
40/S-M12 0301504
FS6-1/9335 FS6-1/9913 FS6-1/0020
600/5A
SD25B 12339.6
MK9961.81 22384
MK9961.81 21491
3RT1034-1AB00 3RH1921-1FA22
3N 3001501
ST10BU 3036123
R130G10B
3TF4210-0B

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.