Overview
SIMATIC ET 200PA SMART • Digital Outputs

6ES7650-8EK70-0AA0 SIMATIC ET 200PA SMART 16DQ 24VDC/0.5A Output Module

Sixteen 24 V DC, 0.5 A outputs with channel diagnostics and a 40-pin front connection for ET 200PA SMART stations using IM 650-8PH.

At a Glance

Brand Siemens
Model 6ES7650-8EK70-0AA0
Product Type Digital output module
Core Function Switching DC actuators with configurable diagnostics
Application ET 200PA SMART stations with IM 650-8PH

Actuator switching

Sixteen outputs switch suitable DC loads at a rated current of 0.5 A per channel.

Diagnostic visibility

Parameterized diagnostics support wire-break detection in both output states and reporting of short circuits or missing group load voltage.

Grouped load circuits

Four-channel potential groups support organized field wiring while retaining isolation from the backplane bus.

Product Overview

6ES7650-8EK70-0AA0 provides sixteen digital outputs for ET 200PA SMART process I/O, with configurable diagnostic reporting for wire breaks, short circuits and load-supply faults.

The outputs are arranged in groups of four, so load-current planning must consider both each channel rating and the total current permitted for each group.

Ordering focus: Confirm the required IM 650-8PH interface, 40-pin front connector, four-channel group loads and correct 24 V DC polarity.
Key Functions

Actuator switching

Sixteen outputs switch suitable DC loads at a rated current of 0.5 A per channel.

Diagnostic visibility

Parameterized diagnostics support wire-break detection in both output states and reporting of short circuits or missing group load voltage.

Grouped load circuits

Four-channel potential groups support organized field wiring while retaining isolation from the backplane bus.

Official Specifications
Digital outputs 16
Rated load voltage 24 V DC
Reverse-polarity protection Not provided
Rated / permissible on-state current 0.5 A / 5 mA–0.6 A per channel
Maximum output-group current 2 A per group at up to 60 °C horizontal or 40 °C vertical mounting
Typical short-circuit response threshold 1.4 A per channel
Maximum L+ / backplane current 100 mA from L+; 100 mA from the 5 V backplane
Typical power loss 6 W
Minimum on-state voltage L+ minus 1.3 V
Maximum off-state leakage current 0.7 mA
Typical switching delay 3 ms on and 3 ms off
Maximum lamp load 5 W
Permitted load resistance 48 Ω–4 kΩ
Switching frequency 100 Hz resistive; 2 Hz DC-13 inductive; 10 Hz lamp load
Maximum signal cable length 1,000 m shielded; 600 m unshielded
Wire-break detection Supported in both output state 0 and output state 1
Potential groups 4 channels per isolated group; isolated from backplane
Front connection 1 × 40-pin connector
Dimensions (W × H × D) 40 × 125 × 120 mm
Approximate weight 300 g
Frequently Asked Questions

Which station interface is required for 6ES7650-8EK70-0AA0?

The module is intended for ET 200PA SMART stations with an IM 650-8PH interface.

Can all four outputs in one group of 6ES7650-8EK70-0AA0 supply 0.5 A?

A four-output group permits a total of 2 A within the specified mounting and temperature conditions.

Does 6ES7650-8EK70-0AA0 protect against reversed load-supply polarity?

Reverse-polarity protection is not provided, so check the 24 V DC wiring before energizing the module.

Can 6ES7650-8EK70-0AA0 detect a broken wire while an output is off?

Wire-break diagnostics are supported in both output state 0 and output state 1.

May outputs on 6ES7650-8EK70-0AA0 be paralleled to raise load current?

Paralleling for increased current is not supported.

What front connector is required by 6ES7650-8EK70-0AA0?

The field connection uses one 40-pin front connector.

What must be considered when measuring an off output on 6ES7650-8EK70-0AA0?

Allow for the specified off-state leakage of up to 0.7 mA when interpreting a voltage measured across the connected load.

Compatibility & Ordering Notes
Before ordering 6ES7650-8EK70-0AA0: Confirm the required IM 650-8PH interface, 40-pin front connector, four-channel group loads and correct 24 V DC polarity.

Before installation

  • Use the module with the specified IM 650-8PH station interface.
  • Check all four-channel potential groups and their total current against the mounting-temperature limits.
  • Confirm the 40-pin connector and field-cable arrangement in the order.
  • Configure diagnostic alarms and verify load-supply polarity before commissioning.
Hot Selling Models
DBG11B-08
SDE1-D10-G2-MS4-C-P1-M12
GE 1693810000
3RT2018-1BB41
ABB 1SDA062111R1 A062111
3RV2011-0HA25 E:03
0110R010BN/HC-20110R010
L-PMPC604-10-16MB
L-PMPC604-10-16 TPM-MPC-604e/100
PKZM0-6.3 XTPR6P3BC1
SVS1-04-L4-S1-E0-C1
GV2M16 9-14A
NCB50-FP-A2-C-P3-V1
L-PMPC604-13-32/4
325P-F1E1

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.