Overview
SIMATIC S7-400 • High-Current Digital Outputs

6ES7422-1BH10-0AA0 SIMATIC S7-400 SM422 16DO 24VDC/2A Output Module

SM422 with sixteen 24 V DC, 2 A outputs, isolation in two groups of eight and paired-channel supply-current limits.

At a Glance

Brand Siemens
Model 6ES7422-1BH10-0AA0
Product Type Digital output module
Core Function Switching DC field loads from the S7-400
Application S7-400 central and expansion I/O racks

Sixteen DC load channels

Provides a 2 A rated current per output for suitable 24 V DC loads.

Paired-current planning

Each adjacent channel pair permits 3 A total up to 40 °C or 2 A total up to 60 °C.

Direct channel indication

Green channel LEDs continue to indicate system state even when the front connector is not inserted.

Product Overview

6ES7422-1BH10-0AA0 switches sixteen DC loads in an S7-400 rack, with the channels electrically separated into two groups of eight.

This 1BH10 version requires load voltage to be applied to both eight-output groups during commissioning, and loss of one group supply can switch off all outputs, making the supply arrangement important during replacement.

Ordering focus: Check the specific 1BH10 supply behavior, energize both eight-output groups and calculate current for each adjacent two-channel supply pair.
Key Functions

Sixteen DC load channels

Provides a 2 A rated current per output for suitable 24 V DC loads.

Paired-current planning

Each adjacent channel pair permits 3 A total up to 40 °C or 2 A total up to 60 °C.

Direct channel indication

Green channel LEDs continue to indicate system state even when the front connector is not inserted.

Official Specifications
Digital outputs 16
Rated electronics and load voltage 24 V DC
Rated output current 2 A per channel
Paired-channel aggregate current 3 A up to 40 °C; 2 A up to 60 °C per adjacent channel pair
Channel grouping and isolation 2 groups of 8; isolated from the backplane
Maximum current consumption 160 mA from backplane; 30 mA from L+ without load
Typical power dissipation 5 W
Minimum on-state output voltage L+ minus 0.5 V
Maximum off-state leakage 0.5 mA
Maximum resistive-load delay 1 ms for either switching transition
Load-resistance range 12 Ω–4 kΩ
Maximum lamp load 10 W
Switching frequency 100 Hz resistive; 0.2 Hz inductive at 1 A or 0.1 Hz at 2 A; 10 Hz lamp load
Short-circuit protection Electronically cyclic; response threshold 2.8–6 A
Maximum signal-cable length 1,000 m shielded; 600 m unshielded
Permissible potential difference 75 V DC or 60 V AC between separate circuits
Insulation test voltage 500 V DC
Status and diagnostics Green LED per channel; no interrupts or diagnostic functions
Dimensions (W × H × D) 25 × 290 × 210 mm
Approximate weight 600 g
Frequently Asked Questions

Must both eight-output groups be supplied when commissioning 6ES7422-1BH10-0AA0?

Apply rated load voltage at least once to each eight-output group during commissioning.

Can loss of one group supply on 6ES7422-1BH10-0AA0 affect the other outputs?

Loss of a group load supply can switch off all outputs, including those in the other group.

Does the eight-channel isolation group define the current budget for 6ES7422-1BH10-0AA0?

The aggregate-current limit applies to adjacent two-channel supply pairs, with 3 A permitted up to 40 °C or 2 A up to 60 °C.

May two outputs on 6ES7422-1BH10-0AA0 be paralleled to raise current capacity?

Paralleling outputs to increase load capability is not permitted.

What can restore an output of 6ES7422-1BH10-0AA0 after short-circuit protection operates?

Change the output signal, interrupt the module load voltage or briefly disconnect the load when reclosing under full load does not occur.

Do the channel LEDs on 6ES7422-1BH10-0AA0 still operate without the front connector?

The channel-status LEDs continue to indicate system state when the front connector is absent.

Can 6ES7422-1BH10-0AA0 report channel diagnostic alarms?

This module has no diagnostic functions or interrupts.

Compatibility & Ordering Notes
Before ordering 6ES7422-1BH10-0AA0: Check the specific 1BH10 supply behavior, energize both eight-output groups and calculate current for each adjacent two-channel supply pair.

Before installation

  • Apply the supply behavior of the exact 1BH10 revision when replacing a module.
  • Provide both eight-output group supplies during commissioning.
  • Calculate current for adjacent pairs 0/1, 2/3 and onward through 14/15.
  • Do not use parallel outputs to increase current, and check the load type and switching rate.
Hot Selling Models
BES00HC BES 516-3005-G-E4-C-S49-00.3
WAGO 2002-1307
VN-14-L-T4-PQ3-VQ3-RO2-B
EWLR008ZMST
ZM-2,4-PKZ2 ZM2,4PKZ2
3RX9307-1AA00
37-1111-003
2/U/BP 2732732
IE5381 IEB3002BBPKG/V4A/US
P363/EA/SVBSW
SBH190-12
6ES5440-8MA12
50/1AS
3044539
PRK85/4 00227

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.