Siemens SIMATIC S7-400 6ES7412-1XF04-0AB0 CPU 412-1

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC S7-400

6ES7412-1XF04-0AB0 CPU 412-1 Central Processing Unit

Siemens 6ES7412-1XF04-0AB0 is the SIMATIC S7-400 CPU 412-1 with separate 72 KB code and data work memory, MPI/PROFIBUS DP communication and fast instruction processing.

At a Glance

Brand Siemens
Model 6ES7412-1XF04-0AB0
Product Type Standard S7-400 programmable controller CPU
Core Function Executes medium-scale machine and process automation programs
Application or Compatible Series SIMATIC S7-400 central and expansion rack systems

Firmware Match

Confirm the installed firmware level and the STEP 7 hardware catalog entry before exchange.

Memory Transfer

Back up the project and match the flash or RAM memory card used by the application.

Bus Parameters

Preserve MPI or PROFIBUS DP addresses, baud rates, node configuration and termination.

Product Overview

Siemens 6ES7412-1XF04-0AB0 is the SIMATIC S7-400 CPU 412-1 with separate 72 KB code and data work memory, MPI/PROFIBUS DP communication and fast instruction processing.

Separate code and data work areas support structured S7-400 applications. The onboard interface handles programming, HMI and PROFIBUS communication tasks. Bit, word and integer operations execute in approximately one tenth of a microsecond.

Ordering focus: confirm the full CPU article, firmware, STEP 7 project, memory-card type and capacity, S7-400 rack slot, MPI or PROFIBUS settings, I/O addressing and startup behavior.
Key Functions

Balanced Work Memory

Separate code and data work areas support structured S7-400 applications.

Integrated MPI/DP

The onboard interface handles programming, HMI and PROFIBUS communication tasks.

Fast Instruction Processing

Bit, word and integer operations execute in approximately one tenth of a microsecond.

Official Specifications
Firmware Version V4.0.0
Integrated Work Memory 72 KB for code and 72 KB for data
Integrated Load Memory 256 KB RAM
Memory Card Expansion Up to 64 MB with a FLASH card or up to 64 MB with a RAM card
Battery-Backed Data All working and load memory retained with the backup battery
Execution Time for Bit, Word and Integer Operations 0.1 µs
Floating-Point Operation Time 0.3 µs
S7 Counters 2,048 counters; retention configurable from Z0 to Z2047, preset Z0 to Z7; count range 1 to 999
S7 Timers 2,048 timers; no preset retentive timers; time range 10 ms to 9,990 s
Marker Memory and Retention 4 KB; adjustable from MB0 to MB4095, preset MB0 to MB15; 1 clock-memory byte
Data Blocks Up to 511 blocks with DB0 reserved; maximum block size 64 KB
Local Data Up to 8 KB configurable; 4 KB preset
Program Blocks Up to 256 function blocks and 256 functions; size limited by work memory
Block Nesting Depth 24 per priority class plus 2 additional levels inside an error OB
I/O Address Area 4 KB inputs and 4 KB outputs; up to 2 KB each through the integrated MPI/DP interface
Process Image Up to 4 KB inputs and 4 KB outputs, configurable; 128 bytes each preset; up to 15 partial process images
Channel Capacity Up to 32,768 digital input/output channels and 2,048 analog input/output channels
Maximum Consistent Data 244 bytes
Frequently Asked Questions

Which memory card types can I use with 6ES7412-1XF04-0AB0?

Use a compatible S7-400 flash or RAM card sized for the archived program and load memory.

What should I compare before exchanging 6ES7412-1XF04-0AB0?

Compare firmware, memory card, rack slot, interface settings, project hardware configuration and backup state.

How much integrated work memory does 6ES7412-1XF04-0AB0 provide?

It provides seventy-two kilobytes for code and a separate seventy-two kilobytes for data.

Can 6ES7412-1XF04-0AB0 connect to a PROFIBUS network?

Yes, the integrated MPI/DP interface can be configured for the supported PROFIBUS application.

Why might 6ES7412-1XF04-0AB0 remain in STOP after replacement?

A firmware, memory-card, hardware-configuration or bus-parameter mismatch can prevent a successful startup.

What I/O address capacity is available on 6ES7412-1XF04-0AB0?

The total address area is four kilobytes for inputs and four kilobytes for outputs.

How should I commission 6ES7412-1XF04-0AB0 in an existing rack?

Load the verified project, check diagnostics, confirm all bus nodes and test controlled outputs before returning to production.

Compatibility & Ordering Notes
Before ordering 6ES7412-1XF04-0AB0: confirm the full CPU article, firmware, STEP 7 project, memory-card type and capacity, S7-400 rack slot, MPI or PROFIBUS settings, I/O addressing and startup behavior.

Compatibility Checklist

  • Match the exact CPU 412-1 hardware and firmware entry in the archived STEP 7 project.
  • Retain the approved flash or RAM memory card and verify that the complete application fits.
  • Restore MPI or PROFIBUS parameters, rack allocation, process images and diagnostic organization blocks.
Hot Selling Models
6GK1543-0AA01
6ES7332-5HB01-0AB0
7000-08111-6300500
3RV1011-1GA10 3RV1901-1A
700-321-1BH02
6FX1151-BD01 570 511.9104.01
RJ1A23D20E
7700-40121-1500300
GV2 M03 021082
6GK1543-1AA01 6ES5376-0AA21
iC60HD6A
3RH1244-1AD00
516-161-I0-L
3LD3054-0TK51
7000-41081-6560150

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.