Siemens SIMATIC S7-400 6ES7407-0KR02-0AA0 PS 407 10 A
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
Siemens · SIMATIC S7-400
6ES7407-0KR02-0AA0 PS 407 10 A Redundant Power Supply
Siemens 6ES7407-0KR02-0AA0 is a SIMATIC S7-400 PS 407 power supply with a 120/230 V AC or DC wide-range input, 10 A backplane output and support for redundant power operation.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7407-0KR02-0AA0 |
| Product Type | Wide-range redundant S7-400 power supply |
| Core Function | Supplies 5 V DC at 10 A and 24 V DC at 1 A to the backplane |
| Application or Compatible Series | SIMATIC S7-400 racks requiring redundant power operation |
Input Selection
Match the installed AC or DC source to the documented wide-range input and protective-conductor wiring.
Rack Allocation
Reserve two S7-400 slots and verify the required backplane current before installation.
Redundant Operation
Check that both power-supply paths, line protection and rack wiring match the existing redundant arrangement.
Product Overview
Siemens 6ES7407-0KR02-0AA0 is a SIMATIC S7-400 PS 407 power supply with a 120/230 V AC or DC wide-range input, 10 A backplane output and support for redundant power operation.
The supply accepts 120/230 V AC or DC sources across the documented input ranges. The unit provides regulated 5 V and 24 V DC outputs for the S7-400 backplane. The internal energy reserve bridges short input interruptions for more than 20 ms.
Key Functions
Wide-Range AC/DC Input
The supply accepts 120/230 V AC or DC sources across the documented input ranges.
Dual Backplane Outputs
The unit provides regulated 5 V and 24 V DC outputs for the S7-400 backplane.
Stored-Energy Buffering
The internal energy reserve bridges short input interruptions for more than 20 ms.
Official Specifications
| Permitted DC Input Range | 88 to 300 V DC |
|---|---|
| Permitted AC Input Range | 85 to 264 V AC |
| Permitted Line Frequency | 47 to 63 Hz |
| Rated Input Current | 0.9 A at 120 V AC; 1.0 A at 120 V DC; 0.5 A at 230 V AC or DC |
| Maximum Inrush Current | 63 A at 230 V AC and 58 A at 300 V DC; 1 ms half-value width |
| Maximum Leakage Current | Less than 3.5 mA |
| Rated Output Voltages | 5.1 V DC and 24 V DC |
| Maximum Output Current | 10 A at 5 V DC and 1.0 A at 24 V DC |
| Mains Buffering Time | More than 20 ms |
| Typical Active Power Input | 95 W |
| Typical Power Loss | 20 W |
| Required Rack Slots | 2 |
| Primary-to-Secondary Isolation | Galvanically isolated |
| Overvoltage Category | Category II |
| Operating Temperature | 0 to 60 °C |
| Electrical Connection | 3 x 1.5 mm² conductors; 3 to 9 mm external cable diameter |
| Dimensions | 50 x 290 x 217 mm |
| Approximate Weight | 1.2 kg |
| Equipment Protection Class | Class I with protective conductor |
| Short-Circuit Protection | Provided |
Frequently Asked Questions
Can 6ES7407-0KR02-0AA0 be powered from either AC or DC mains?
Yes, the supply accepts documented 120/230-volt AC or DC input sources within their permitted ranges.
How many rack slots must I reserve for 6ES7407-0KR02-0AA0?
Reserve two adjacent slots in the S7-400 rack for installation.
What backplane current can 6ES7407-0KR02-0AA0 deliver?
The supply provides up to ten amperes at five volts and one ampere at twenty-four volts.
Will 6ES7407-0KR02-0AA0 ride through a short mains interruption?
The stored energy provides more than twenty milliseconds of buffering under the specified conditions.
Which protective wiring is required for 6ES7407-0KR02-0AA0?
Use the protective-conductor connection and conductor sizes specified for Class I equipment.
What must be compared before replacing 6ES7407-0KR02-0AA0 in a redundant rack?
Compare the two supply paths, rack slot allocation, line voltage, output demand and redundancy wiring.
What ambient temperature is allowed for 6ES7407-0KR02-0AA0?
The standard operating range is zero to sixty degrees Celsius.
Compatibility & Ordering Notes
Compatibility Checklist
- Verify that the target rack is a SIMATIC S7-400 installation with two available slots.
- Calculate the connected 5 V and 24 V backplane load before energizing the replacement.
- Match both incoming supply paths and protective devices to the installed redundant design.