Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7331 1kf02 0ab0 sm331 analog input-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens SIMATIC S7-300 6ES7331-1KF02-0AB0 SM 331 Analog Input

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Product Overview
  • Key Functions
  • Official Specifications
  • Frequently Asked Questions
  • Compatibility & Ordering Notes
  • Hot Selling Models
  • Recommended Products
Overview

Siemens · SIMATIC S7-300

6ES7331-1KF02-0AB0 SM 331 Analog Input Module

Siemens 6ES7331-1KF02-0AB0 is the SIMATIC S7-300 SM 331 isolated analog input module with eight channels for voltage, current, resistance and resistance-temperature sensors at up to 13-bit resolution.

At a Glance

Brand Siemens
Model 6ES7331-1KF02-0AB0
Product Type Isolated eight-channel analog input module
Core Function Converts process voltage, current, resistance and RTD signals for the controller
Application or Compatible Series SIMATIC S7-300 and ET 200M systems

Signal Assignment

Set each measurement group for the connected voltage, current, resistance or RTD sensor type.

Protection Limits

Keep applied voltage and current below the stated continuous and short-duration destruction limits.

Connector Mapping

Transfer all forty-pole front-connector wiring and measurement-range settings channel by channel.

Product Overview

Siemens 6ES7331-1KF02-0AB0 is the SIMATIC S7-300 SM 331 isolated analog input module with eight channels for voltage, current, resistance and resistance-temperature sensors at up to 13-bit resolution.

The module accepts voltage, current, resistance and several resistance-temperature sensor types. Galvanic isolation separates the analog channels from the S7-300 backplane bus. Multiple bipolar and unipolar voltage ranges plus standard current ranges support varied field instruments.

Ordering focus: verify every measurement range, sensor type, front-connector terminal, wiring method, shielding arrangement and configured channel group.
Key Functions

Multi-Signal Acquisition

The module accepts voltage, current, resistance and several resistance-temperature sensor types.

Isolated Measurement

Galvanic isolation separates the analog channels from the S7-300 backplane bus.

Configurable Ranges

Multiple bipolar and unipolar voltage ranges plus standard current ranges support varied field instruments.

Official Specifications
Backplane Current at 5 V DC 90 mA maximum
Typical Power Loss 0.4 W
Maximum Digital Resolution 13 bit
Conversion Time 66 ms
Front Connector 1 x 40-pole
Maximum Continuous Voltage Input 12 V
Short-Duration Voltage Limit 30 V for no more than 1 s
Maximum Current Input 40 mA
Supported Voltage Ranges 0 to 10 V; 1 to 5 V; ±1 V; ±5 V; ±10 V; ±50 mV; ±500 mV
Voltage Input Resistance 100 kΩ
Supported Current Range 0 to 20 mA
Current Input Resistance 100 Ω
Resistance Measurement Channels 8
Supported Resistance Sensors Pt100, Ni100, Ni1000, LG-Ni1000, PTC and KTY
Thermocouple Measurement Not supported
Channel Isolation Inputs isolated from backplane bus
Dimensions 40 x 125 x 120 mm
Approximate Weight 250 g
Frequently Asked Questions

Which field signals may be wired to 6ES7331-1KF02-0AB0?

The module accepts supported voltage, current, resistance and resistance-temperature sensor signals.

How must measurement ranges be set on 6ES7331-1KF02-0AB0?

Configure each channel group for the connected sensor type and its exact electrical range.

Can 6ES7331-1KF02-0AB0 read thermocouples directly?

No, this module is not designed for direct thermocouple measurement.

What input overload must be avoided on 6ES7331-1KF02-0AB0?

Keep voltage below twelve volts continuously and current below forty milliamperes.

How long does 6ES7331-1KF02-0AB0 need for a conversion?

The specified conversion time is sixty-six milliseconds.

Which connector wiring should be copied when exchanging 6ES7331-1KF02-0AB0?

Copy every terminal assignment from the forty-pole front connector together with the channel-group settings.

What should I compare if readings from 6ES7331-1KF02-0AB0 are incorrect?

Compare the configured range, sensor wiring method, polarity, shielding and input resistance requirements.

Compatibility & Ordering Notes
Before ordering 6ES7331-1KF02-0AB0: verify every measurement range, sensor type, front-connector terminal, wiring method, shielding arrangement and configured channel group.

Compatibility Checklist

  • Confirm the station is a SIMATIC S7-300 or ET 200M system with a compatible hardware configuration.
  • Check every connected sensor against the supported voltage, current, resistance or RTD ranges.
  • Preserve the forty-pole connector mapping and module parameters before replacement.
Hot Selling Models
BAUM3X7 30-62-7
6GK7342-5DA00-0XE0
LC1D12
2963815
ABB MS325
EHAA-D-L2-45-L2-45
RM1A48D50
3RT1015-1AP01 3RU1116-0KB0
5SY42 MCB A20 5SY4220-5
NH000GG50V16 K222097
280835 51114499
CAD11A230-600
55.34.9.024.5070
5SL4204-7
5SY4204-5 5SY42 MCB-A4

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.