siemens 6es7321 1ff01 0aa0 s7 300 sm 321 eight channel ac input module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7321-1FF01-0AA0 S7-300 SM 321 Eight-Channel AC Input Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIEMENS SIMATIC S7-300

6ES7321-1FF01-0AA0 S7-300 SM 321 Eight-Channel AC Input Module

Eight AC input channels with a 20-pin front connector, paired isolation groups and a maximum 25 ms switching delay.

At a Glance

Brand Siemens
Model 6ES7321-1FF01-0AA0
Product Type AC digital input signal module
Core Function Monitoring of mains-level switching signals
Application SIMATIC S7-300 AC input installations

AC field signals

The inputs are rated for 120/230 V AC at 47–63 Hz.

Paired references

The input isolation groups each contain two channels.

Input-state LEDs

Green indicators show the state of each input.

Product Overview

6ES7321-1FF01-0AA0 monitors eight AC field signals in a SIMATIC S7-300 station. The SM 321 uses IEC 61131 type-1 inputs and a 20-pin front connector for its rated 120/230 V AC wiring arrangement.

Each pair of input channels forms an isolation group, and optocouplers separate the inputs from the backplane. Switching delays can reach 25 ms, making the module suitable for ordinary AC contact monitoring rather than high-speed edge capture.

Ordering focus: Match the AC voltage class, paired reference circuits, connector and sensor off-state current before transferring field wiring.
Key Functions

Acquire AC switching states

The module accepts rated 120/230 V AC inputs with a 47–63 Hz operating frequency.

Separate paired field circuits

Input channels are grouped in pairs, with optocoupler separation from the backplane.

Monitor normal AC contact operation

The maximum input delay is 25 ms for both switching-on and switching-off transitions.

Official Specifications
Digital input channels 8; IEC 61131 type 1
Rated AC input 120/230 V AC at 47–63 Hz
Logic voltage thresholds Signal 0: 0–40 V; signal 1: 79–264 V
Typical signal-1 current 6.5 mA at 120 V; 11 mA at 230 V
Maximum input delay 25 ms on both transitions; not parameterizable
Simultaneously active inputs 8 up to 60 °C horizontally or 40 °C vertically
Maximum two-wire sensor quiescent current 2 mA
Maximum field-cable length 1,000 m shielded; 600 m unshielded
Maximum 5 V backplane current 29 mA
Typical power loss 4.9 W
Isolation arrangement Groups of 2 inputs; optocoupler separation from backplane
Insulation test voltage 4,000 V DC
Required front connector 20-pin
Indicators and alarms Green input-state LEDs; no diagnostic or hardware-interrupt function
Dimensions and approximate weight 40 × 125 × 120 mm (W × H × D); 240 g
Frequently Asked Questions

Can a 24 V DC sensor drive an input of 6ES7321-1FF01-0AA0?

The module is intended for 120/230 V AC signals and its specified logic-1 voltage starts at 79 V.

Can all eight channels of 6ES7321-1FF01-0AA0 be active at 60 °C?

All eight inputs may be active up to 60 °C in the horizontal installation position.

How many channels share an isolation group on 6ES7321-1FF01-0AA0?

Each isolation group contains two input channels.

Can 6ES7321-1FF01-0AA0 reliably capture short pulses below its maximum input delay?

The input delay can reach 25 ms, so pulse timing must allow for that response.

Which front connector does 6ES7321-1FF01-0AA0 require?

Use the specified 20-pin front connector.

What off-state sensor current can 6ES7321-1FF01-0AA0 accept?

The maximum permissible quiescent current of a two-wire sensor is 2 mA.

Will 6ES7321-1FF01-0AA0 report a channel fault through an SF indicator?

The module provides green channel-state LEDs but no red SF group-error indicator or diagnostic function.

Compatibility & Ordering Notes
Before ordering 6ES7321-1FF01-0AA0: Select the AC input arrangement and coordinate the two-channel isolation groups, 20-pin connector and 25 ms maximum response time.

Compatibility Checklist for 6ES7321-1FF01-0AA0

  • Use rated 120/230 V AC field signals at 47–63 Hz.
  • Maintain the paired channel-reference arrangement.
  • Limit two-wire sensor quiescent current to 2 mA.
  • Use a 20-pin front connector and preserve the required field wiring.
Hot Selling Models
3RV1031-4DA10 3RV1901-2E
700-323-1BH00
C-M12F05-05X050PU05.0-GA-073461
CDQ2B20-50D
285-135 0185-0135
6W0.3 10/5A
3210157
3RT1046-1AP00
G9SB-2002-C
03758 01.NL250.40G.30E.P
C60N2PB25A23641
VAA-4E4A-KE-ZEJQ/E2L-KRO
ADNM-25-APA-15Z1-17Z2
707040/1-888-888-23
ERSDQB32-15DR

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.