- Match the complete CN article number and eight-relay arrangement.
- Provide a 20.4–28.8 V DC relay-coil supply.
- Keep each output within 2 A and each common within 10 A.
- Provide external short-circuit protection and do not parallel relay outputs.
- Account for relay switching life and reduce lamp turn-on surge below the output surge rating.
6ES7222-1HF22-0XA8 SIMATIC S7-200 CN EM 222 Eight-Relay Output Module
An EM 222 expansion with eight dry-contact relay outputs, a 2 A point rating and a separate 24 V DC relay-coil supply.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7222-1HF22-0XA8 |
| Product Type | Digital expansion module |
| Core Function | Extending PLC-controlled load circuits |
| Application | Compatible S7-22X CPU assemblies |
Eight relay channels
Dry contacts switch AC or DC load circuits within the specified voltage limits.
Separate coil power
The relay coils use a 20.4–28.8 V DC supply.
Grouped load circuits
Both the 2 A point limit and 10 A common limit apply.
Product Overview
6ES7222-1HF22-0XA8 adds eight relay-switched output channels to a compatible S7-200 CN controller. Each dry contact has a 2 A rated output current, with the relay coil circuit powered separately at 24 V DC.
The contacts can switch DC and AC loads within their respective voltage ranges. Relay switching speed, contact life, lamp inrush and external short-circuit protection are important when selecting the field circuits.
Key Functions
Switch AC or DC loads
The dry contacts operate over 5–30 V DC or 5–250 V AC.
Expand the output bank
Eight relay channels add discrete load-control points to the CPU expansion assembly.
Separate coil and contact circuits
The relay coil-to-contact isolation is tested at 1500 V AC for one minute.
Official Specifications
| Relay outputs | 8 |
|---|---|
| Rated current per output | 2 A |
| Maximum current per common | 10 A |
| Contact working-voltage range | 5–30 V DC or 5–250 V AC |
| Relay-coil supply range | 20.4–28.8 V DC |
| 5 V DC bus current | 40 mA |
| 24 V DC coil current | 9 mA per energized output |
| Typical module power loss | 2 W |
| Maximum output surge | 5 A for 4 s at 10% duty cycle |
| Maximum new-contact resistance | 0.2 Ω |
| Maximum relay switching time | 10 ms |
| Maximum switching frequency | 1 Hz |
| Mechanical life at no load | 10000000 cycles |
| Contact life at rated load | 100000 cycles |
| Coil-to-contact isolation test | 1500 V AC for 1 minute |
| Maximum output cable length | 500 m shielded; 150 m unshielded |
| Simultaneous output operation | All outputs at 55 °C horizontally or 45 °C vertically |
| Integrated output short-circuit protection | None |
| Housing dimensions | 45 × 80 × 62 mm (W × H × D) |
Frequently Asked Questions
May I switch both AC and DC load circuits with 6ES7222-1HF22-0XA8?
The dry-contact outputs operate within 5–30 V DC or 5–250 V AC.
What current limit applies to a shared common on 6ES7222-1HF22-0XA8?
Each common is limited to 10 A and every individual output must remain within its 2 A rating.
May I connect relay outputs of 6ES7222-1HF22-0XA8 in parallel to increase the load current?
Parallel connection of two relay outputs is not permitted.
Is 6ES7222-1HF22-0XA8 suitable for a fast pulse-output application?
The relay output has a maximum switching frequency of 1 Hz and a maximum switching time of 10 ms.
Which supply must I provide for the relay coils of 6ES7222-1HF22-0XA8?
Supply the coil circuit with 20.4–28.8 V DC and allow 9 mA for each energized output.
How far may I run the output cables from 6ES7222-1HF22-0XA8?
The maximum output cable length is 500 m when shielded or 150 m when unshielded.
What lamp-load inrush should I consider when using 6ES7222-1HF22-0XA8?
Keep lamp turn-on surge below the 5 A output surge rating because excessive inrush can reduce relay life by 75%.