siemens 6es7221 1bh22 0xa0 em 221 16 channel digital input module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7221-1BH22-0XA0 EM 221 16-Channel Digital Input Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview
SIEMENS SIMATIC S7-200

6ES7221-1BH22-0XA0 EM 221 16-Channel Digital Input Module

A 16-channel EM 221 input expansion with grouped optocoupler isolation and plug-in I/O terminals for SIMATIC S7-22X CPUs.

At a Glance

Brand Siemens
Model 6ES7221-1BH22-0XA0
Product Type EM 221 digital input expansion module
Core Function Acquires 16 sinking or sourcing 24 V DC input signals
Application S7-22X CPU expansion for machine sensors and discrete status signals

16 discrete inputs

Connect 24 V DC sensors using sinking or sourcing input wiring.

Grouped isolation

The optocoupler-isolated input channels are arranged in groups of four.

Serviceable terminals

Plug-in I/O terminals support field-wiring maintenance.

Product Overview

6ES7221-1BH22-0XA0 expands a SIMATIC S7-22X CPU with sixteen 24 V DC digital inputs for machine interlocks, position detection and discrete process status.

The input stage supports sinking and sourcing connections, including two-wire sensors within the specified off-state current limit; grouped isolation and defined switching thresholds support orderly field wiring.

Ordering focus: Match the S7-22X CPU, 24 V sensor wiring, four-channel isolation groups and available 5 V backplane current.
Key Functions

Discrete signal acquisition

Sixteen IEC 61131 type 1 inputs accept a 0 to 5 V low signal and a +15 to +30 V high signal.

Sensor and cable integration

Two-wire sensors are supported with a maximum quiescent current of 1 mA, with cable limits of 500 m shielded or 300 m unshielded.

Grouped field connections

Optocoupler isolation is provided in groups of four channels, while plug-in I/O terminals allow the terminal assembly to be handled during maintenance.

Official Specifications
Rated input voltage 24 V DC
Input characteristic IEC 61131 type 1
Signal 0 voltage 0 to 5 V
Signal 1 voltage +15 to +30 V
Typical signal 1 current 4 mA
Maximum rising-edge input delay 4.5 ms at rated input voltage
Maximum shielded cable length 500 m
Maximum unshielded cable length 300 m
Maximum two-wire sensor quiescent current 1 mA
Input electrical isolation Optocoupler; channel groups of four
Isolation test 500 V AC for 1 minute
I/O terminal connection Plug-in terminals
Maximum 5 V backplane current 70 mA
Typical power loss 3 W
Dimensions (W × H × D) 71.2 × 80 × 62 mm
Approximate weight 160 g
Frequently Asked Questions

Which CPU generation accepts 6ES7221-1BH22-0XA0?

The expansion module is intended for SIMATIC S7-22X CPUs.

Can 6ES7221-1BH22-0XA0 accommodate both sinking and sourcing sensor connections?

The input circuitry supports both sinking and sourcing connections at 24 V DC.

What off-state leakage is acceptable for two-wire sensors on 6ES7221-1BH22-0XA0?

A connected two-wire sensor must have a quiescent current no greater than 1 mA.

How are the input isolation groups organized on 6ES7221-1BH22-0XA0?

Optocoupler isolation separates the digital inputs in groups of four channels.

How much 5 V expansion-bus current should be reserved for 6ES7221-1BH22-0XA0?

The module requires up to 70 mA from the 5 V DC backplane supply.

Which field-cable limits apply to 6ES7221-1BH22-0XA0?

The maximum permitted input-cable length is 500 m with shielding or 300 m without shielding.

Are the field I/O terminals removable on 6ES7221-1BH22-0XA0?

The module uses plug-in I/O terminals.

Compatibility & Ordering Notes
Before ordering 6ES7221-1BH22-0XA0: Select this 16-input EM 221 for an S7-22X CPU and verify the sensor common wiring, input-group allocation and expansion-bus current budget.

Compatibility Checklist for 6ES7221-1BH22-0XA0

  • Use an S7-22X CPU with the required expansion capacity.
  • Match 24 V DC sinking or sourcing sensor connections to the input circuit.
  • Keep two-wire sensor quiescent current at or below 1 mA.
  • Observe four-channel isolation groups and the applicable cable-length limit.
  • Allow up to 70 mA from the 5 V DC backplane supply.
Hot Selling Models
UM55PA2
18M2000 P1K-IBSL
3B40-00
WL18-2P135
6SC6100-0SA01
ETP30 P 28310-0-1241431 F4038
MS6-LRP-1/4-D7-A8M
7000-74641-7960300
SRX-MP-1SFP-GE
T175N22E0C51
FSN11P
T175N22E0C31
Werma 84312055
B&R PS5
XU8-M18MB230

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.