SIMATIC S7-200

6ES7216-2AD23-0XB0 SIMATIC S7-200 CPU 226 DC/DC/DC Compact Controller

A DC-powered CPU 226 with integrated transistor outputs, two RS485 interfaces and high-speed counting and pulse functions.

At a Glance

Brand Siemens
Model 6ES7216-2AD23-0XB0
Product Type Compact programmable controller
Core Function Executing machine-control logic and field I/O
Application SIMATIC S7-200 automation

Integrated DC machine I/O

Twenty-four digital inputs and sixteen transistor outputs connect local machine signals.

Two programmable serial interfaces

The two RS485 interfaces provide PPI, MPI-slave communication or programmable serial exchange.

Fast counting and pulse generation

Six high-speed counters and two high-speed outputs support pulse acquisition and pulse-width or frequency control.

Product Overview

6ES7216-2AD23-0XB0 combines the CPU, digital field terminals and serial communication interfaces in a compact S7-200 unit.

Its program memory changes with the run-time editing setting, while integrated high-speed counters and pulse outputs handle faster machine signals independently of ordinary switching I/O.

Ordering focus: Match the DC supply, transistor-output loads, program-memory requirement, serial protocol and expansion-module current budget.
Key Functions

Integrated DC machine I/O

Twenty-four digital inputs and sixteen transistor outputs connect local machine signals.

Two programmable serial interfaces

The two RS485 interfaces provide PPI, MPI-slave communication or programmable serial exchange.

Fast counting and pulse generation

Six high-speed counters and two high-speed outputs support pulse acquisition and pulse-width or frequency control.

Official Specifications
CPU supply 24 V DC nominal; permissible range 20.4–28.8 V
Typical power loss 11 W
Program work memory 24 kB; 16 kB with active run-time editing
Data work memory 10 kB
Digital inputs 24 inputs; isolation groups of 13 and 11
Input switching levels Low: 0–5 V DC; high: at least 15 V DC
Typical high-state input current 2.5 mA
Configurable standard-input delay 0.2–12.8 ms
Digital outputs 16 DC transistor outputs; up to 0.75 A per resistive load
Output-group current Maximum 6 A per group up to 40 °C in all positions, or up to 55 °C horizontally
High-speed counters 6 signed 32-bit counters at up to 30 kHz; quadrature A/B counting up to 20 kHz
High-speed pulse outputs 2 at up to 20 kHz with pulse-width and frequency modulation
Serial connections 2 integrated RS485 interfaces; PPI at 9.6, 19.2 or 187.5 kbit/s
Internal counter and timer resources 256 counters and 256 timers
Retentive-data buffering Up to 100 h with capacitor, minimum 70 h at 40 °C; typically 200 days with optional battery module
Sensor supply 24 V DC, maximum 400 mA, electronic short-circuit protection
Expansion-module capacity Maximum 7 expansion modules
Operating temperature 0–55 °C horizontal; 0–45 °C vertical
Enclosure protection IP20
Dimensions and approximate mass 196 × 80 × 62 mm (W × H × D); 550 g
Frequently Asked Questions

Why does the available program memory of 6ES7216-2AD23-0XB0 change between 16 and 24 kB?

Enabling run-time editing reduces the available program work memory from 24 kB to 16 kB.

Can I replace a relay-output CPU with 6ES7216-2AD23-0XB0 without reviewing the field loads?

The outputs are DC transistors rather than relays, so the load voltage and current must match the transistor-output ratings.

Can I use a custom ASCII protocol on the serial interfaces of 6ES7216-2AD23-0XB0?

The RS485 interfaces support freely programmable serial data exchange with ASCII transfer rates from 1.2 to 115.2 kbit/s.

Does 6ES7216-2AD23-0XB0 provide built-in short-circuit protection for the transistor outputs?

The digital outputs require external short-circuit protection.

Can I always fit seven expansion modules to 6ES7216-2AD23-0XB0?

The CPU supports up to seven S7-22x expansion modules, but the available expansion-supply current can reduce the usable configuration.

How long can the high-speed counter wiring be on 6ES7216-2AD23-0XB0?

The maximum shielded cable length for high-speed counter signals is 50 m.

Must I reduce the ambient-temperature limit when mounting 6ES7216-2AD23-0XB0 vertically?

Vertical mounting has a maximum operating temperature of 45 °C compared with 55 °C for horizontal mounting.

Compatibility & Ordering Notes
Before ordering 6ES7216-2AD23-0XB0: Match the DC supply, transistor-output loads, program-memory requirement, serial protocol and expansion-module current budget.

Before installation

  • Use a 24 V DC supply within the 20.4–28.8 V operating range.
  • Size DC loads and external output protection for the transistor channels and output-group current limits.
  • Use S7-22x expansion modules and include their demand in the available 5 V expansion-supply budget.
  • Select the required PPI, MPI-slave or programmable serial operation and retain the correct high-speed signal wiring.
Hot Selling Models
M225-SE0655
9SUB/S/FRONT/Q
6GK1901-1BE00-0AA0
CDB620-001
3RA1120-4BD26-0BB4
A507/130
5SJ4314-7HG42
32136
4.48x1.78
2482.330
BR-090.02,540,UR
285-634 51169960
4.5T-5-RSM 50/S1587/S1149 U-79807
04883160
BD5934.48

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.