SIMATIC S7-200 CN

6ES7214-2AD23-0XB8 SIMATIC S7-200 CN CPU 224XP DC/DC/DC

CPU 224XP CN with fourteen DC inputs, ten transistor outputs, two analog inputs, one analog output and two programmable serial interfaces.

At a Glance

Brand Siemens
Model 6ES7214-2AD23-0XB8
Product Type Compact programmable controller
Core Function Discrete logic, analog control and pulse processing
Application S7-200 CN machinery with DC field circuits

Mixed local signal control

Fourteen digital inputs and ten transistor outputs operate alongside two analog inputs and one analog output.

Fast counter and pulse tasks

High-speed counter inputs and two pulse outputs support fast measurement and pulse-command applications.

Expandable serial controller

Seven expansion modules and two programmable serial ports support the selected station layout.

Product Overview

6ES7214-2AD23-0XB8 combines discrete control, integrated analog channels and high-speed pulse functions in a DC-powered S7-200 CN controller.

The CPU supports seven expansion modules subject to the station power budget and provides two serial interfaces for PPI or user-programmed communication.

Ordering focus: Match the DC/DC/DC output variant, analog signal requirements, serial-port roles and expansion-module power budget.
Key Functions

Mixed local signal control

Fourteen digital inputs and ten transistor outputs operate alongside two analog inputs and one analog output.

Fast counter and pulse tasks

High-speed counter inputs and two pulse outputs support fast measurement and pulse-command applications.

Expandable serial controller

Seven expansion modules and two programmable serial ports support the selected station layout.

Official Specifications
DC input power 20.4–28.8 V DC
Supply current at 24 V 120 mA CPU only; 900 mA at maximum load
Typical power loss 8 W
Digital inputs 14; 24 V DC sinking/sourcing
Digital outputs 10 transistor outputs; no relay outputs
Integrated analog channels 2 inputs and 1 output
Program memory 12288 bytes with RUN-mode editing; 16384 bytes without RUN-mode editing
Data memory 10240 bytes
I/O image resources 128 digital input bits and 128 digital output bits; 32 analog input words and 32 analog output words
Maximum expansion 7 expansion modules, subject to the CPU power budget
High-speed counters 6 total; single-phase: 4 at 30 kHz and 2 at 200 kHz; two-phase: 3 at 20 kHz and 1 at 100 kHz
Pulse outputs 2 at up to 100 kHz
Timers and counters 256 timers and 256 counters
Boolean instruction time 0.22 µs per instruction
Serial interfaces 2 RS485 ports
Serial communication rates PPI / MPI slave: 9.6, 19.2 and 187.5 kbaud; Freeport: 1.2–115.2 kbaud
Expansion and sensor power 660 mA at 5 V DC for expansion; 280 mA at 24 V DC for sensors
Memory backup Supercapacitor: 100 h typical, 70 h minimum at 40°C; optional battery: 200 days typical
Clock Built-in real-time clock
Dimensions and approximate weight 140 × 80 × 62 mm (W × H × D); 390 g
Frequently Asked Questions

How does enabling RUN-mode editing change the program capacity of 6ES7214-2AD23-0XB8?

Available program storage is twelve thousand two hundred eighty-eight bytes with RUN-mode editing and sixteen thousand three hundred eighty-four bytes without it.

Can I use 6ES7214-2AD23-0XB8 for two one-hundred-kilohertz pulse-output channels?

The DC-output CPU provides two pulse outputs rated up to one hundred kilohertz.

Which high-speed inputs on 6ES7214-2AD23-0XB8 support the two-hundred-kilohertz counting rate?

Counters HC4 and HC5 support two-hundred-kilohertz single-phase counting with a logic-on input level above four volts DC.

Can I add seven expansion modules to 6ES7214-2AD23-0XB8 regardless of their current demand?

Seven modules is the maximum count and the complete station must also remain within the CPU expansion-power budget.

Can a serial port on 6ES7214-2AD23-0XB8 run a user-programmed Freeport protocol?

Both built-in RS485 ports support user-programmed Freeport communication at rates from one-point-two to one hundred fifteen-point-two kbaud.

Can I wire the ten outputs of 6ES7214-2AD23-0XB8 as isolated relay contacts?

This DC/DC/DC variant has transistor outputs and no relay outputs.

How long is the supercapacitor memory-backup period of 6ES7214-2AD23-0XB8?

The backup period is typically one hundred hours with a minimum of seventy hours at forty degrees Celsius.

Compatibility & Ordering Notes
Before ordering 6ES7214-2AD23-0XB8: Match the DC/DC/DC output variant, analog signal requirements, serial-port roles and expansion-module power budget.

Before installation

  • Use a DC supply within the specified range and match the transistor outputs to the DC field circuits.
  • Configure CPU 224XP in the S7-200 STEP 7-Micro/WIN project and account for the selected RUN-mode editing capacity.
  • Calculate expansion and sensor current together before selecting the maximum seven-module arrangement.
  • Apply the special signal-level requirements of the high-speed input group and preserve a program backup before replacement.
Hot Selling Models
6ES5267-8MA11
ES-I304
E83 C25 6KA C256KA
L22 G302368
WT32-B230 1007397
20041292
IG-3005-APKG
ZV1H 235-11Z-ST
281-601
7000-17061-2921500
6ES5735-2BF00
GS 0313085
S8VK-S03024
08.24.35/S10 M8
101-11120

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.