Overview
SIMATIC ET 200iSP • Interface and Electronics Terminal Bases

6ES7193-7AA00-0AA0 SIMATIC ET 200iSP TM-IM/EM60S Screw-Terminal Base

TM-IM/EM60S screw-terminal base for an IM 152 interface module and a compatible electronic module, with a power-bus terminating module included.

At a Glance

Brand Siemens
Model 6ES7193-7AA00-0AA0
Product Type Terminal base module
Core Function Supporting the interface and field-wiring assembly
Application ET 200iSP distributed I/O stations

Prewired field connections

Actuator and sensor wiring can be completed on the terminal base before fitting the plug-in modules.

Interface-module support

The left position accepts the IM 152 interface module, while the right position accepts an electronic module.

Shield and bus connection

A 9-pin Sub-D socket provides the PROFIBUS RS 485-IS connection, and a spring contact bonds the cable shield to the mounting rail.

Product Overview

6ES7193-7AA00-0AA0 provides the terminal-base arrangement for an IM 152 interface module on the left and a compatible electronic module on the right in an ET 200iSP station.

The screw-terminal construction permits prewiring, and a spring contact connects the PROFIBUS cable shield to the mounting rail and the station equipotential-bonding system.

Ordering focus: Select the IM/EM arrangement, screw-terminal wiring and suitable hazardous-area enclosure, and include the station rail in the equipotential-bonding arrangement.
Key Functions

Prewired field connections

Actuator and sensor wiring can be completed on the terminal base before fitting the plug-in modules.

Interface-module support

The left position accepts the IM 152 interface module, while the right position accepts an electronic module.

Shield and bus connection

A 9-pin Sub-D socket provides the PROFIBUS RS 485-IS connection, and a spring contact bonds the cable shield to the mounting rail.

Official Specifications
Input and output voltage range 20.4–28.8 V DC
Maximum input and output current 4 A DC
Plug-in positions 2
Field-wiring terminals Screw terminals
Field-terminal arrangement 4 groups of 4 terminals
PROFIBUS connection 9-pin Sub-D socket for RS 485-IS
Terminal-screw tightening torque 0.5–0.7 N·m
Mounting arrangement Front mounting and rail mounting
Cable-shield bonding Spring contact to the mounting rail
Hazardous-area application Gas Zone 1; dust Zone 21 with a corresponding enclosure
Dimensions (W × H × D) 60 × 190 × 52 mm
Approximate weight 235 g
Frequently Asked Questions

Can I prewire 6ES7193-7AA00-0AA0 before fitting the interface and electronic modules?

The terminal base permits prewiring before the plug-in modules are installed.

Which module goes in the left-hand position of 6ES7193-7AA00-0AA0?

The IM 152 interface module occupies the left-hand position and the electronic module the right-hand position.

Which PROFIBUS connector should I plan for 6ES7193-7AA00-0AA0?

The base provides a 9-pin Sub-D socket for the PROFIBUS RS 485-IS connection.

Does 6ES7193-7AA00-0AA0 include the power-bus terminating module?

The power-bus terminating module is included.

How should the screw terminals of 6ES7193-7AA00-0AA0 be tightened?

Tighten the terminal screws to 0.5–0.7 N·m.

How is the PROFIBUS cable shield connected through 6ES7193-7AA00-0AA0?

A spring contact connects the cable shield to the mounting rail and its equipotential bonding.

Can I install 6ES7193-7AA00-0AA0 openly in a Zone 21 dust area?

Zone 21 installation requires a corresponding enclosure.

Compatibility & Ordering Notes
Before ordering 6ES7193-7AA00-0AA0: Select the IM/EM arrangement, screw-terminal wiring and suitable hazardous-area enclosure, and include the station rail in the equipotential-bonding arrangement.

Before installation

  • Use the IM/EM layout with the interface module on the left and a compatible electronic module on the right, excluding the 2 DO relay module.
  • Select screw-terminal wiring and tighten the terminal screws to 0.5–0.7 N·m.
  • Keep the PROFIBUS shield connection and mounting-rail equipotential bonding intact.
  • Use the required hazardous-area enclosure and the included power-bus termination in the station arrangement.
Hot Selling Models
ADN-20-95-IPA
B10 5SY4110-6
OP-87360 RJ45
efector200 E20443 FT-00-PPV-M6
MS4-EM1-1/4-S 541259 + MS4-EE-1/4-10V24-S
ET3-5-C15 ET3C15
8WD4220-5BF
Allen Bradley 1746-A7
RJCS1A60D50EPPO
BFK458-06N
C9900-K730
LB1LB03P03 0.25 - 0.4A 021062
TH 9513
FBG31C-01 8222932.13
Allen-Bradley 700-CF400ZA

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.