- Start a separate potential group at this base.
- Protect the supply using the specified 10 A type B or C breaker arrangement.
- Respect both the 2 A process-terminal limit and 10 A bus limits.
- Match process and AUX color labels to the chosen electronic module.
6ES7193-6BP20-0DA0 ET 200SP BU15-P16+A10+2D BaseUnit
A 15 mm-wide A0 base with 16 process terminals, 10 AUX terminals and a new potential-group arrangement.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7193-6BP20-0DA0 |
| Product Type | Push-in wiring base |
| Core Function | Providing field wiring and an isolated potential-group start |
| Application | Type A0 ET 200SP electronic modules |
New potential group
The power group is separated from the group to the left.
Additional AUX wiring
Ten AUX terminals supplement the process connections.
Push-in conductors
The terminal range is 0.14–2.5 mm².
Product Overview
6ES7193-6BP20-0DA0 provides the wiring base for a compatible type A0 ET 200SP module while starting a new potential group. The P1 and P2 buses are separated from the group on the left rather than continuing its load supply.
The BU15-P16+A10+2D arrangement provides process, AUX and power-bus connections in a 15 mm-wide housing. The base and its external protection must be selected together with the electronic module and the current of the connected loads.
Key Functions
Start a separately supplied group
The BaseUnit creates a new potential group with separation from the preceding group.
Distribute auxiliary connections
Ten AUX terminals provide additional wiring points alongside the sixteen process terminals.
Support compact field wiring
Push-in connections accept 0.14–2.5 mm² conductors and an optional integrated shield connection.
Official Specifications
| Rated supply | 24 V DC |
|---|---|
| Maximum bus current | 10 A for P1/P2 and AUX buses |
| Maximum process-terminal current | 2 A |
| Potential arrangement | New potential group; no continuation from the left; group separation |
| Insulation test voltage | 707 V DC, type test |
| Terminal allocation | 16 process terminals; 10 AUX terminals; 2 P1/P2 connections; no add-on terminals |
| Connection method and conductor range | Push-in; 0.14–2.5 mm² / AWG 26–14 |
| Shield connection | Optional system-integrated connection |
| Process-terminal color labels | CC00–CC09 |
| AUX-terminal color labels | CC71–CC73 |
| Operating temperature | Horizontal: −30 to +60 °C; vertical: −30 to +50 °C |
| Maximum operating altitude | 5,000 m; restrictions above 2,000 m |
| Minimum dew point | −60 °C; suitable for dry-room applications |
| Dimensions and approximate weight | 15 × 141 × 35 mm (W × H × D); 50 g |
Frequently Asked Questions
Will 6ES7193-6BP20-0DA0 continue the load group from the BaseUnit to its left?
The base starts a new potential group and does not continue the preceding group.
How should I protect the power-supply lines feeding 6ES7193-6BP20-0DA0?
Use a 24 V DC 10 A miniature circuit breaker with type B or C tripping characteristic.
Can a process terminal on 6ES7193-6BP20-0DA0 carry the same current as a power bus?
Each process terminal is limited to 2 A, while the P1/P2 and AUX buses are rated up to 10 A.
Which wire sizes can I terminate on 6ES7193-6BP20-0DA0?
The push-in terminals accept conductor cross-sections from 0.14 to 2.5 mm².
How many AUX wiring points does 6ES7193-6BP20-0DA0 provide?
The base provides ten terminals connected to the AUX bus.
Which labels identify the AUX terminals of 6ES7193-6BP20-0DA0?
The specified AUX-terminal color labels are CC71 to CC73.
What height should I allow for 6ES7193-6BP20-0DA0 in the station?
The BaseUnit is 141 mm high, 15 mm wide and 35 mm deep.