Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
siemens 6es7193 4cb30 0aa0 simatic et 200s tm e15c24 01 terminal module-0

For SIEMENS

Home >  Products >  For SIEMENS

Siemens 6ES7193-4CB30-0AA0 SIMATIC ET 200S TM-E15C24-01 Terminal Module

Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months

  • Overview
  • Hot Selling Models
  • Recommended Products
Overview

SIEMENS SIMATIC ET 200S

6ES7193-4CB30-0AA0 SIMATIC ET 200S TM-E15C24-01 Terminal Module

An eight-connection spring-terminal base for 15 mm ET 200S electronics with a continuous, untapped AUX1 bus.

At a Glance

Brand Siemens
Model 6ES7193-4CB30-0AA0
Product Type Electronic module base
Core Function Modular field termination
Application ET 200S sensor and actuator wiring

Full numbered terminal set

The electronic module assigns all positions from 1 to 8 in the 2 × 4 layout.

Spring termination

Cage Clamp terminals secure the wires after the opening tool is withdrawn.

No auxiliary tap

AUX1 passes through this base without local A4/A8 terminal access.

Product Overview

6ES7193-4CB30-0AA0 forms the TM-E15C24-01 spring-terminal wiring base beneath a 15 mm ET 200S electronic module.

Its eight numbered positions support the terminal assignments of the inserted electronics, and its separate auxiliary bus continues through the station without a local field connection.

Ordering focus: Use the -01 eight-terminal version when the electronic circuit needs numbered positions 1–8 rather than AUX1 access.
Key Functions

Expose the electronic circuit terminals

The installed module defines each field connection across numbered terminals 1 through 8.

Connect prepared wires by spring clamp

A 3 mm screwdriver opens the spring terminal for an 11 mm stripped conductor end.

Maintain the shared bus path

Solid power buses and AUX1 continuity carry the station potentials through adjacent bases.

Official Specifications
Terminal arrangement 2 × 4 connections
Connection technology Spring terminals (Cage Clamp)
AUX1 routing Continuous to the potential group on the left
AUX1 terminal access No terminal access
Bare solid and flexible conductor range 0.14–2.5 mm²
Flexible conductor range with ferrule 0.14–1.5 mm²
Wire stripping length 11 mm
Conductors per connection 1; alternatively 2 totaling up to 1.5 mm² in a shared ferrule
Maximum wire insulation diameter 3.1 mm at 1.5 mm²; 3.8 mm at 2.5 mm²
Wiring tool Screwdriver with 3 mm blade
Dimensions (W × H × D) 15 × 132 × 43 mm
Approximate module weight 65 g
Frequently Asked Questions

Are positions 4 and 8 available to the electronic circuit on 6ES7193-4CB30-0AA0?

Yes, all numbered terminals 1–8 are assigned by the electronic module on this -01 base.

Does 6ES7193-4CB30-0AA0 support Spring termination for mobile equipment?

No, AUX1 remains a pass-through bus without local terminal access on this version.

How do I insert a flexible wire into 6ES7193-4CB30-0AA0?

Strip 11 mm, open the spring terminal with a 3 mm screwdriver, insert the wire fully and withdraw the screwdriver.

Can a 2.5 mm² ferruled lead be installed in 6ES7193-4CB30-0AA0?

No, ferruled flexible conductors are limited to 1.5 mm² even though bare solid or flexible conductors may be up to 2.5 mm².

Will 6ES7193-4CB30-0AA0 occupy more rail width than one 15 mm electronic module?

No, each base is 15 mm wide and matches the width of the supported electronic module.

How much does a single 6ES7193-4CB30-0AA0 base weigh?

One TM-E15C24-01 terminal module weighs approximately 65 g.

Can I replace the terminal box of 6ES7193-4CB30-0AA0 without taking the base off the rail?

Yes, replacement of the terminal box does not require removal of the terminal module from the rail.

Compatibility & Ordering Notes
Before ordering 6ES7193-4CB30-0AA0: Order the TM-E15C24-01 spring version for the required eight-position electronic-module assignment, accounting for five bases per packing unit and no local AUX1 tap.

Compatibility Checklist for 6ES7193-4CB30-0AA0

  • Use the electronic module terminal plan for positions 1–8.
  • Select the spring-clamp version required by the cabinet wiring practice.
  • Route any necessary AUX1 field connection to an accessible terminal module.
  • Keep ferruled conductors within 0.14–1.5 mm².
Hot Selling Models
6ES5470-4UA12
21DO16/3 2750646
08-FA-49
885500 LF-06480
885030K03M050 1200661038
6ES5947-3UA21
6154500
6ES5256-3AA11
8UD1731-0AB25
4062K 18815862
5ST3021
LC1D12BD LAD4TBDL
305K-PS-C-2-S4
MXS20-30
BZ40i 3x230/400V AURBDXAXXAX3XX2

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.