- Keep the protective-earth tier bonded to the cabinet ground.
- Preserve the numbered wiring groups and module-class coding.
- Make address changes effective with the required STOP/RUN transition.
- Use the specified fuse and correct the fault before returning to RUN.
6ES7193-0CB20-0XA0 ET 200B TB2-4/DC Four-Tier Terminal Block
A 235 mm-wide four-tier TB2-4/DC base for the 32-channel terminal arrangement, with a 2.5 A sensor-supply fuse.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7193-0CB20-0XA0 |
| Product Type | Fixed digital-station wiring base |
| Core Function | Keeping field conductors connected during electronics service |
| Application | ET 200B distributed digital stations |
Two terminal banks
The numbered tiers cover the 32-channel station arrangement.
Fourth earth tier
Protective-earth terminals are integrated below the numbered connections.
Station identity
The base retains the station-number and coding controls.
Product Overview
6ES7193-0CB20-0XA0 forms the four-tier screw-terminal foundation for the 32-channel ET 200B digital wiring arrangement. The wide TB2-4/DC base keeps the field wiring and protective-earth tier in place when the electronics block is exchanged.
The terminal numbering extends to 96, and the sensor-supply fuse is rated at 2.5 A. Station address changes take effect through a STOP/RUN transition, so replacement and recommissioning must preserve both the wiring and base settings.
Key Functions
Organize the 32-channel field wiring
The TB2-4/DC provides three numbered screw-terminal tiers and a fourth protective-earth tier.
Retain the base settings
The station-number controls and module-class coding remain with the wiring base.
Support controlled service work
The electronics block and sensor fuse can be serviced using the specified STOP sequence.
Official Specifications
| Terminal structure | 32-channel arrangement; 4 screw-terminal tiers |
|---|---|
| Numbered terminal allocation | 1–32, 33–64 and 65–96 |
| Protective-earth connections | Additional fourth terminal tier |
| Sensor-supply fuse | TR5-T 2.5 A, 250 V miniature fuse |
| Station-number selector | Two-digit 00–99 setting range |
| Coding mechanism | 6-position slide switch |
| Bare terminal-block dimensions | 235 × 126.9 × 56.9 mm (W × H × D) |
| Installed protection | IP20; protection class I |
| Operating temperature | 0–60 °C in preferred horizontal installation; 0–40 °C in other positions |
| Storage and transport temperature | −40 to +70 °C |
| Relative humidity | 15–95 %, indoor, without condensation |
| Atmospheric pressure | Operation: 795–1,080 hPa; storage/transport: 660–1,080 hPa |
| Vibration test | 0.075 mm at 10 to <57 Hz; 1 g at 57 to <150 Hz |
| Shock test | 15 g peak, 11 ms half-sine |
| Electrostatic discharge immunity | 8 kV air discharge; 4 kV contact discharge |
Frequently Asked Questions
What happens to the internal logic when the fuse in 6ES7193-0CB20-0XA0 trips?
A tripped fuse de-energizes the station internal logic.
When does a new station-number setting on 6ES7193-0CB20-0XA0 become active?
The station number becomes valid after a STOP/RUN transition.
How should I bond the PE connection of 6ES7193-0CB20-0XA0 to the cabinet?
Connect the PE terminal to the protective-ground conductor or cabinet ground with a low-impedance connection.
Which coding setting should I use for standard 24 V digital electronics on 6ES7193-0CB20-0XA0?
Set the coding slide to position 1 for the 24 V digital module class.
Can I replace the fuse of 6ES7193-0CB20-0XA0 without removing its electronics block?
The fuse replacement procedure requires setting STOP and removing the electronics block before replacing the fuse.
How much mounting width does 6ES7193-0CB20-0XA0 require?
The bare terminal block is 235 mm wide.
Can 6ES7193-0CB20-0XA0 operate in an environment where moisture condenses on the station?
The permitted indoor relative humidity is 15–95 % without condensation.