Siemens SIMATIC ET 200iSP AFD8 Active Field Distributor 6ES7157-0AG82-0XA0
Manufacturer: Siemens
Condition: Brand New
Lead Time: In Stock
Origin: Germany
Warranty: 12 Months
Email: [email protected]
whatsApp: +86-18150117685
- Overview
- Product Overview
- Key Functions
- Official Specifications
- Frequently Asked Questions
- Compatibility & Ordering Notes
- Hot Selling Models
- Recommended Products
Overview
SIEMENS · SIMATIC ET 200iSP
6ES7157-0AG82-0XA0 SIMATIC ET 200iSP AFD8 Active Field Distributor
The AFD8 active field distributor provides eight short-circuit-proof spur lines, line or ring termination functions and IP66 protection for PROFIBUS PA and FOUNDATION Fieldbus H1 installations.
At a Glance
| Brand | Siemens |
|---|---|
| Model | 6ES7157-0AG82-0XA0 |
| Product Type | eight-spur active field distributor |
| Core Function | Distributes PROFIBUS PA or FOUNDATION Fieldbus H1 to eight protected spur lines |
| Application or Compatible Series | Fieldbus line or ring topologies with ET 200iSP and FDC 157 |
Exact Identification
Match 6ES7157-0AG82-0XA0 character by character and confirm the complete SIMATIC ET 200iSP AFD8 Active Field Distributor designation.
Interface Arrangement
Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.
Configuration Check
Preserve the approved engineering project, network parameters and application data used by the installed system.
Product Overview
The AFD8 active field distributor provides eight short-circuit-proof spur lines, line or ring termination functions and IP66 protection for PROFIBUS PA and FOUNDATION Fieldbus H1 installations.
Each field connection is short-circuit protected for resilient instrument wiring. The device supports line and ring arrangements with automatic bus termination. The IP66 enclosure and wide temperature range suit demanding process installations.
Key Functions
Eight Protected Spurs
Each field connection is short-circuit protected for resilient instrument wiring.
Automatic Topology Support
The device supports line and ring arrangements with automatic bus termination.
Outdoor-Grade Housing
The IP66 enclosure and wide temperature range suit demanding process installations.
Official Specifications
| Product Version | 01 |
|---|---|
| Fieldbus Systems | PROFIBUS PA and FOUNDATION Fieldbus H1 |
| Spur Lines | 8 |
| Spur Protection | Short-circuit proof |
| Auxiliary Supply | Not required; bus powered |
| Permissible Bus Voltage | 16 to 32 V DC |
| No-Load Current | 34 mA |
| End-of-Line Additional Current | 30 mA |
| Maximum Current per Spur | 514 mA |
| Minimum Power Loss | 544 mW |
| Maximum Power Loss | 4.1 W |
| Topology | Line or ring |
| Automatic Bus Termination | Supported |
| Operating Temperature | -40 to +70 °C |
| Storage Temperature | -40 to +85 °C |
| Relative Humidity | Up to 95% |
| Degree of Protection | IP66 |
| Dimensions Without Cable Glands | 360 x 120 x 83 mm |
| Mounting Dimensions | 344 x 82 mm |
| Weight | 3 kg |
Frequently Asked Questions
How many field-device spurs are provided by 6ES7157-0AG82-0XA0?
Eight short-circuit-protected spur connections are available.
Which fieldbus systems can use 6ES7157-0AG82-0XA0?
It supports PROFIBUS PA and FOUNDATION Fieldbus H1.
Does 6ES7157-0AG82-0XA0 need a separate auxiliary supply?
No; it is powered from the fieldbus segment.
Can 6ES7157-0AG82-0XA0 be installed in a fieldbus ring?
Yes; line and ring topologies are supported with automatic termination behavior.
What enclosure rating does 6ES7157-0AG82-0XA0 provide?
The housing is rated IP66.
What current limit applies to each spur on 6ES7157-0AG82-0XA0?
The stated maximum current per spur is 514 mA.
What must be checked before replacing 6ES7157-0AG82-0XA0?
Verify segment voltage, topology, FDC 157 arrangement, spur allocation and cable-gland sealing.
Compatibility & Ordering Notes
Compatibility Checklist
- Confirm the installed segment uses PROFIBUS PA or FOUNDATION Fieldbus H1.
- Check line or ring topology and the required automatic termination arrangement.
- Verify every spur current and the complete bus-power budget before connection.