Overview

SIEMENS · SIMATIC DP field-device connection

6ES7157-0AD82-0XA0 SIMATIC DP FDC157 Ex [ia] DP/PA Coupler

The FDC157 Ex [ia] couples PROFIBUS DP to an intrinsically safe PROFIBUS PA segment and supplies up to 110 mA to as many as thirty-one connected field devices.

At a Glance

Brand Siemens
Model 6ES7157-0AD82-0XA0
Product Type intrinsically safe PROFIBUS DP/PA fieldbus coupler
Core Function Couples PROFIBUS DP to an intrinsically safe IEC 61158-2 fieldbus segment
Application or Compatible Series PROFIBUS PA installations using Ex [ia] field devices and extended-temperature operation

Exact Identification

Match 6ES7157-0AD82-0XA0 character by character and confirm the complete SIMATIC DP FDC157 Ex [ia] DP/PA Coupler designation.

Interface Arrangement

Confirm the installed supply, ports, field connections and required accessories before wiring the replacement.

Configuration Check

Preserve the approved engineering project, network parameters and application data used by the installed system.

Product Overview

The FDC157 Ex [ia] couples PROFIBUS DP to an intrinsically safe PROFIBUS PA segment and supplies up to 110 mA to as many as thirty-one connected field devices.

The coupler converts between the PROFIBUS DP and PROFIBUS PA transmission systems. The Ex [ia] output is specified for connected field devices within the documented gas-group limits. Separate DP and PA activity LEDs plus supply monitoring support installation and troubleshooting.

Ordering focus: confirm the Ex [ia] version, DP and PA wiring, fieldbus current budget, hazardous-area calculation, supply range and environmental limits.

Key Functions

DP-to-PA Fieldbus Coupling

The coupler converts between the PROFIBUS DP and PROFIBUS PA transmission systems.

Intrinsically Safe Field Segment

The Ex [ia] output is specified for connected field devices within the documented gas-group limits.

Integrated Bus Diagnostics

Separate DP and PA activity LEDs plus supply monitoring support installation and troubleshooting.

Official Specifications

Rated Supply 24 V DC
Permissible Supply Range 20.4 to 28.8 V DC
Reverse Polarity Protection Yes
Stored Energy Time During Supply Failure 5 ms
Maximum Current Consumption 400 mA
Typical Power Loss 7 W
Maximum PROFIBUS DP Rate 45.45 kbit/s
PROFIBUS DP Connector 9-pin Sub-D
PROFIBUS PA Rate 31.25 kbit/s
Maximum Ex [ia] No-Load Voltage 15 V
Maximum Ex [ia] Short-Circuit Current 247 mA
Maximum Ex [ia] Output Power 1.95 W
Isolation Test Level 500 V AC
Degree of Protection IP20
Operating Temperature -25 to +60 °C
Maximum Relative Humidity in Operation 95%
Maximum Field Devices 31
Maximum Total Field-Device Current 110 mA

Frequently Asked Questions

What network transition does 6ES7157-0AD82-0XA0 provide?

It couples PROFIBUS DP to an intrinsically safe PROFIBUS PA field segment.

How many PA field devices can connect behind 6ES7157-0AD82-0XA0?

Up to thirty-one field devices can be connected within the total current limit.

What current is available to field devices from 6ES7157-0AD82-0XA0?

The maximum total output current for the field segment is 110 mA.

Which connector is used on the DP side of 6ES7157-0AD82-0XA0?

The PROFIBUS DP connection uses a 9-pin Sub-D interface.

What temperature range applies to 6ES7157-0AD82-0XA0?

The permitted operating range is -25 to +60 degrees Celsius.

Which LEDs help commission 6ES7157-0AD82-0XA0?

Yellow DP and PA activity LEDs plus the green 24 V supply LED show bus and power status.

What must I calculate before connecting devices to 6ES7157-0AD82-0XA0?

Verify the fieldbus current budget and every intrinsic-safety parameter for the complete segment.

Compatibility & Ordering Notes

Before ordering 6ES7157-0AD82-0XA0: confirm the Ex [ia] version, DP and PA wiring, fieldbus current budget, hazardous-area calculation, supply range and environmental limits.

Compatibility Checklist

  • Use only field devices and wiring permitted by the complete intrinsic-safety calculation.
  • Keep the total PA segment current within 110 mA and the connected-device count within the documented limit.
  • Match the PROFIBUS DP connector, grounding, shielding and supply arrangement used by the installed segment.
Hot Selling Models
SAC-4P-10.0-PUR/M12FS
RS-KMS1-A
SACC-MINMS-5CON-PG13/2.5
56.34.8.110.0040
DPA51CM44
MGN61305
3RU1126-4AD0 3RU1926-3AA01
H100
4.4T-0.5-RSC 4.4T/S3060 U-38550
2368.000
4 - 0912034
K1 /10.0/10.00/H7/16.00/H7
ES500137 1124.09
8000-88000-0000000
Allen-Bradley 700-HLT1Z

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop

Evolo Automation is not an authorized distributor unless otherwise specified, representative, or affiliate of the manufacturer of this product. All trademarks and documents are the property of their respective owners and are provided for identification and informational.