Siemens SIMATIC DP FDC157 DP/PA Coupler 6ES7157-0AD82-0XA0
Fabricator: Siemens
Condición: Nuevo
Plazo de Entrega: En Stock
Origo: Germania
Garantía: 12 Meses
Email: [email protected]
whatsapp: +86-18150117685
- Praevisio
- Hot Selling Models
- Producta Recommandata
Praevisio
- Usus sit tantum dispositivorum field et conductorum quae per integram calculationem intrinsic-safety permittuntur.
- Tene totalem currentem PA segmenti infra 110 mA et numerum dispositivorum connexorum infra limitem documentatum.
- Conformare connexorem PROFIBUS DP, terram, scutum et dispositionem alimentationis quae ab installato segmento utuntur.
SIEMENS · SIMATIC DP field-device connection
6ES7157-0AD82-0XA0 SIMATIC DP FDC157 Ex [ia] DP/PA Coupler
The FDC157 Ex [ia] couples PROFIBUS DP to an intrinsically safe PROFIBUS PA segment and supplies up to 110 mA to as many as thirty-one connected field devices.
Ad Primum Aspectum
| Marca | Siemens |
|---|---|
| Modelus | 6ES7157-0AD82-0XA0 |
| Typus Producti | intrinsically safe PROFIBUS DP/PA fieldbus coupler |
| Functio principalis | Couples PROFIBUS DP to an intrinsically safe IEC 61158-2 fieldbus segment |
| Applicatio vel series compatibiles | PROFIBUS PA installations using Ex [ia] field devices and extended-temperature operation |
Identificatio exacta.
Match 6ES7157-0AD82-0XA0 character by character and confirm the complete SIMATIC DP FDC157 Ex [ia] DP/PA Coupler designation.
Arrangementum Interfacis
Confirmare ante connexionem substitutionis supplitum installatum, portus, connexiones campestres et accessoria requisa.
Configuration Check
Servare projectum ingenieriae approbatum, parametres rete et data applicationis quae systema installatum utitur.
Product Overview
The FDC157 Ex [ia] couples PROFIBUS DP to an intrinsically safe PROFIBUS PA segment and supplies up to 110 mA to as many as thirty-one connected field devices.
Coupler convertit inter systemata transmissionis PROFIBUS DP et PROFIBUS PA. Ex [ia] output specificatur pro dispositivis campi connexis intra limites gas-group documentatas.
Key Functions
Couplicatio Fieldbus DP-ad-PA
Coupler convertit inter systemata transmissionis PROFIBUS DP et PROFIBUS PA.
Segmentum Campi Intrinsece Securum
Ex [ia] output specificatur pro dispositivis campi connexis intra limites gas-group documentatas.
Diagnosticum Bus Integrum
Separatae luculae activitatis DP et PA, simul cum monitoratione supply, suadent installationem et investigationem errorum.
Official Specifications
| Rated Supply | 24 V DC |
|---|---|
| AMPLITUDO ADMISSIBILIS FONDIS | 20,4 ad 28,8 V DC |
| Protectio ab polaritate inversa | Ita est |
| Tempus Energiae Conservatae Durante Defectu Supply | 5 ms |
| Maxima Consumptio Electrica | 400 mA |
| Perditio potentiæ typica | 7 W |
| Maxima velocitas PROFIBUS DP | 45,45 kbit/s |
| Conector PROFIBUS DP | 9-pin Sub-D |
| Velocitas PROFIBUS PA | 31,25 kbit/s |
| Maxima Tensio Ex [ia] Sine Onere | 15 V |
| Maximum Ex [ia] Short-Circuit Current | 247 mA |
| Maximum Ex [ia] Output Power | 1.95 W |
| Isolation Test Level | 500 V AC |
| Gradus praesidium | IP20 |
| Temperatura operationis | -25 to +60 °C |
| Maximum Relative Humidity in Operation | 95% |
| Maximus Numerus Dispositivorum Campi | 31 |
| Maximum Total Field-Device Current | 110 mA |
Quaestiones Frequentes
What network transition does 6ES7157-0AD82-0XA0 provide?
It couples PROFIBUS DP to an intrinsically safe PROFIBUS PA field segment.
How many PA field devices can connect behind 6ES7157-0AD82-0XA0?
Up to thirty-one field devices can be connected within the total current limit.
What current is available to field devices from 6ES7157-0AD82-0XA0?
The maximum total output current for the field segment is 110 mA.
Which connector is used on the DP side of 6ES7157-0AD82-0XA0?
The PROFIBUS DP connection uses a 9-pin Sub-D interface.
What temperature range applies to 6ES7157-0AD82-0XA0?
The permitted operating range is -25 to +60 degrees Celsius.
Which LEDs help commission 6ES7157-0AD82-0XA0?
Flavus DP et PA activitatis LED, praeterea viridis 24 V alimentationis LED, statum bus et alimentationis ostendunt.
Quid ego calculare debeo antequam dispositiva ad 6ES7157-0AD82-0XA0 conectam?
Verifica rationem currentis fieldbus et omnes parametres intrinsic-safety pro integro segmento.